Tianhao Yuan

Dr. Tianhao Yuan

School of Environmental and Municipal Engineering, North China University of Water Resources and Electric Power
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Applied Thermal Engineering
Verified
Journal Article
Closed access
YDYan Ding
Yan Ding
QZQiang Zhang
Qiang Zhang
TYTianhao Yuan
Tianhao Yuan
FYFan Yang
Fan Yang

26 October 2023 in Processes
Verified
Journal Article
Open access
PDF file
TYTianhao Yuan
Tianhao Yuan
ZLZeyu Liu
Zeyu Liu
LZLinlin Zhang
Linlin Zhang
SDSuiju Dong
Suiju Dong
JZJilong Zhang
Jilong Zhang
An air-conditioning system (ACS), which consumes large amounts of high-grade energy, is essential for maintaining the indoor thermal environment of modern buildings. However, an ACS consumes almost half of the total energy of the building. Therefore, it is necessary to reduce the energy consumption of the ACS to promote energy conservation and emission reduction in the building sector. In fact, there is an abundance of waste heat and low-grade energies with the potential to be utilized in ACS in nature, but many of them are not utilized efficiently or cannot be utilized at all due to the low efficiency of thermal energy conversion. Known as a passive thermal transfer device, the application of a heat pipe (HP) in the ACS has shown explosive growth in recent years. HPs have been demonstrated to be an effective method for reducing building cooling and heating demands and energy consumption in ACS with experimental and simulation methods. This paper summarizes the different HP types applied in the ACS and provides brief insight into the performance enhancement of the ACS integrated with HP. Four types of HPs, namely tubular HP (THP), loop HP (LHP), pulsating HP (PHP) and flat HP (FHP), are presented. Their working principles and scope of applications are reviewed. Then, HPs used in natural cooling system, split air conditioner (SAC), centralized ACS (CACS) and cooling terminal devices are comprehensively reviewed. Finally, the heat transfer characteristics and energy savings of the above systems are critically analyzed. The results show that the performance of the HP is greatly affected by its own structure, working fluid and external environmental conditions. The energy saving of ACS coupled with HP is 3–40.9%. The payback period of this system ranges from 1.9–10 years. It demonstrates that the HP plays a significant role in reducing ACS energy consumption and improving indoor thermal comfort.

8 September 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
LZLinlin Zhang
Linlin Zhang
ZSZhonghua Shi
Zhonghua Shi
TYTianhao Yuan
Tianhao Yuan
In this paper, a dynamic heat transfer model for the vertical double U-tube borehole heat exchanger (BHE) was developed to comprehensively address the coupled heat transfer between the in-tube fluid and the soil with groundwater advection. A new concept of the heat transfer effectiveness was also proposed to evaluate the BHE heat exchange performance together with the index of the heat transfer rate. The moving finite line heat source model was selected for heat transfer outside the borehole and the steady-state model for inside the borehole. The data obtained in an on-site thermal response test were used to validate the physical model of the BHE. Then, the effects of soil type, groundwater advection velocity, inlet water flow rate, and temperature on the outlet water temperature of BHE were explored. Results show that ignoring the effects of groundwater advection in sand gravel may lead to deviation in the heat transfer rate of up to 38.9% of the ground loop design. The groundwater advection fosters the heat transfer of BHE. An increase in advection velocity may also help to shorten the time which takes the surrounding soil to reach a stable temperature. The mass flow rate of the inlet water to the BHE should be more than 0.5 kg·s−1 but should not exceed a certain upper limit under the practical engineering applications with common scale BHE. The efficiency of the heat transfer of the double U-tube BHE was determined jointly by factors such as the soil’s physical properties and the groundwater advection velocity.

11 October 2024 in Processes
Verified
Journal Article
Open access
PDF file
SDSuiju Dong
Suiju Dong
JCJuanjuan Chen
Juanjuan Chen
CLChunwang Lv
Chunwang Lv
TYTianhao Yuan
Tianhao Yuan
YIN LIUYIN LIU
YIN LIU
ZLZeyu Liu
Zeyu Liu
The heat pipe (HP) is widely applied in the thermal management field at present. In order to make use of the low-grade and renewable energies to maintain building thermal comfort in the heating season, more and more studies with respect to improving the thermal performance of the building heating system integrated with the HP (BHSIHP), such as the floor heating system integrated with the HP (FHSIHP), the thermal storage wall heating system integrated with the HP (TSWIHP), conventional wall integrated with the HP (WIHP) and radiator heating system integrated with the HP (RHSIHP), are conducted. This paper aims to summarize different types of HPs applied in the building heating system and offers an overview of the thermal performance improvement for the BHSIHP. The thermal response, thermal conductivity, thermal resistance, heat capacity, heat transfer coefficient, temperature distribution, thermal storage and heat release capacity are always selected to investigate characteristics of the BHSIHP. Results show that the thermal performance of the FHSIHP, the TSWIHP, the WIHP and the RHSIHP is more outstanding than that of the conventional heating system. The thermal performance of the BHSIHP is affected by heat source temperature, installation tilt angle, working fluid, and filling ratio of the HP. The heat source temperature, which positively affects the performance of the BHSIHP, is crucial for the selection of the working fluid and filling ratio. However, the performance of the BHSIHP is increased first and then decreased with the increase of the installation tilt angle. The optimal filling ratio of the working fluid has been proven not to be a fixed value.

7 December 2023 in Processes
Verified
Journal Article
Open access
PDF file
TYTianhao Yuan
Tianhao Yuan
ZLZeyu Liu
Zeyu Liu
LZLinlin Zhang
Linlin Zhang
DFDongyang Fan
Dongyang Fan
JCJun Chen
Jun Chen
Artificial intelligence algorithms (AIAs) have gained widespread adoption in air conditioning load prediction. However, their prediction accuracy is substantially influenced by the quality of training samples. To improve the prediction accuracy of air conditioning load, this study presents an AIA prediction model based on the method of similarity sample screening. Initially, the comprehensive similarity coefficient between samples was obtained by using the gray correlation method improved with information entropy. Subsequently, a subset of closely related samples was extracted from the original dataset and employed to train the artificial intelligence prediction model. Finally, the trained AIA prediction model was used to predict the air conditioning load. The results illustrate that the method of similarity sample screening effectively improved the prediction accuracy of BP neural network (BPNN) and extreme learning machine (ELM) prediction models. However, it is essential to note that this approach may not be suitable for genetic algorithm BPNN (GABPNN) and support vector regression (SVR) models.

1 November 2017 in Procedia Engineering
Verified
Journal Article
Open access
PDF file
TYTianhao Yuan
Tianhao Yuan
NZNeng Zhu
Neng Zhu
KYKun Yang
Kun Yang
In order to improve the cooling performance of the ground source heat pump (GSHP) system, save the operating cost and reduce the heat discharged into the ground soil, a new free cooling control strategy is proposed in this paper, with which the circulating water in the ground heat exchanger is used to cool the building directly. Firstly, an office building located in Tianjin is selected. Then, the measurement of the GSHP system is conducted during the cooling season. Finally, the experimental evaluation of the new strategy is performed. The results show that the free cooling strategy can meet the cooling demand of the case building at the beginning of the cooling season, there is no dewing phenomenon on the floor surface during the floor radiation free cooling period and the average system energy efficiency ratio (EER) (with the value of 49.29) of the free cooling mode is 16.6 times that of active cooling mode. The electricity consumption and operation cost have a great saving potential. The total heat discharged into the ground soil is reduced largely. This will slow the performance deterioration of the GSPH system.