Alain Lalande

Dr. Alain Lalande

Université de Bourgogne, Dijon, France
+1
orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2018 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
OBOlivier Bernard
Olivier Bernard
Alain LalandeAlain Lalande
Alain Lalande
CZClement Zotti
Clement Zotti
FCFrederick Cervenansky
Frederick Cervenansky
XYXin Yang
Xin Yang
PJPierre-Marc Jodoin
Pierre-Marc Jodoin
Delineation of the left ventricular cavity, myocardium and right ventricle from cardiac magnetic resonance images (multi-slice 2D cine MRI) is a common clinical task to establish diagnosis. The automation of the corresponding tasks has thus been the subject of intense research over the past decades. In this paper, we introduce the “Automatic Cardiac Diagnosis Challenge” dataset (ACDC), the largest publicly-available and fully-annotated dataset for the purpose of Cardiac MRI (CMR) assessment. The dataset contains data from 150 multi-equipments CMRI recordings with reference measurements and classification from two medical experts. The overarching objective of this paper is to measure how far state-of-the-art deep learning methods can go at assessing CMRI, i.e. segmenting the myocardium and the two ventricles as well as classifying pathologies. In the wake of the 2017 MICCAI-ACDC challenge, we report results from deep learning methods provided by nine research groups for the segmentation task and four groups for the classification task. Results show that the best methods faithfully reproduce the expert analysis, leading to a mean value of 0.97 correlation score for the automatic extraction of clinical indices and an accuracy of 0.96 for automatic diagnosis. These results clearly open the door to highly-accurate and fully-automatic analysis of cardiac CMRI. We also identify scenarios for which deep learning methods are still failing. Both the dataset and detailed results are publicly available on-line, while the platform will remain open for new submissions.

29 January 2006 in Nature Genetics
Verified
Journal Article
Closed access
PDF file
LZLimin Zhu
Limin Zhu
RVRoger Vranckx
Roger Vranckx
PKPhilippe Khau Van Kien
Philippe Khau Van Kien
Alain LalandeAlain Lalande
Alain Lalande
NBNicolas Boisset
Nicolas Boisset
XJXavier Jeunemaitre
Xavier Jeunemaitre

16 March 2023 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
YSYoussef Skandarani
Youssef Skandarani
PJPierre-Marc Jodoin
Pierre-Marc Jodoin
Alain LalandeAlain Lalande
Alain Lalande
Generative adversarial networks (GANs) have become increasingly powerful, generating mind-blowing photorealistic images that mimic the content of datasets they have been trained to replicate. One recurrent theme in medical imaging, is whether GANs can also be as effective at generating workable medical data, as they are for generating realistic RGB images. In this paper, we perform a multi-GAN and multi-application study, to gauge the benefits of GANs in medical imaging. We tested various GAN architectures, from basic DCGAN to more sophisticated style-based GANs, on three medical imaging modalities and organs, namely: cardiac cine-MRI, liver CT, and RGB retina images. GANs were trained on well-known and widely utilized datasets, from which their FID scores were computed, to measure the visual acuity of their generated images. We further tested their usefulness by measuring the segmentation accuracy of a U-Net trained on these generated images and the original data. The results reveal that GANs are far from being equal, as some are ill-suited for medical imaging applications, while others performed much better. The top-performing GANs are capable of generating realistic-looking medical images by FID standards, that can fool trained experts in a visual Turing test and comply to some metrics. However, segmentation results suggest that no GAN is capable of reproducing the full richness of medical datasets.

1 January 2017 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
JBJorge Zavala Bojorquez
Jorge Zavala Bojorquez
SBStéphanie Bricq
Stéphanie Bricq
CAClement Acquitter
Clement Acquitter
FBFrançois Brunotte
François Brunotte
PWPaul M. Walker
Paul M. Walker
Alain LalandeAlain Lalande
Alain Lalande

14 August 2018 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
CZClement Zotti
Clement Zotti
ZLZhiming Luo
Zhiming Luo
Alain LalandeAlain Lalande
Alain Lalande
PJPierre-Marc Jodoin
Pierre-Marc Jodoin
In this paper, we present a novel convolutional neural network (CNN) architecture to segment images from a series of short-axis cardiac magnetic resonance slices (CMRI). The proposed model is an extension of the U-net that embeds a cardiac shape prior and involves a loss function tailored to the cardiac anatomy. Our system takes as input raw MR images, requires no manual preprocessing or image cropping and is trained to segment the endocardium and epicardium of the left ventricle, the endocardium of the right ventricle, as well as the center of the left ventricle. With its multi-resolution grid architecture, the network learns both high and low-level features useful to register the shape prior as well as accurately localize the borders of the cardiac regions. Experimental results obtained on the ACDC-MICCAI 2017 dataset show that our model segments multi-slices CMRI (left and right ventricle contours) in 0.17 second with an average Dice coefficient of 0.91 and an average 3D Hausdorff distance of 9.5 mm.

17 June 2020 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
NPNathan Painchaud
Nathan Painchaud
YSYoussef Skandarani
Youssef Skandarani
TJThierry Judge
Thierry Judge
OBOlivier Bernard
Olivier Bernard
Alain LalandeAlain Lalande
Alain Lalande
PJPierre-Marc Jodoin
Pierre-Marc Jodoin
Convolutional neural networks (CNN) have had unprecedented success in medical imaging and, in particular, in medical image segmentation. However, despite the fact that segmentation results are closer than ever to the inter-expert variability, CNNs are not immune to producing anatomically inaccurate segmentations, even when built upon a shape prior. In this paper, we present a framework for producing cardiac image segmentation maps that are guaranteed to respect pre-defined anatomical criteria, while remaining within the inter-expert variability. The idea behind our method is to use a well-trained CNN, have it process cardiac images, identify the anatomically implausible results and warp these results toward the closest anatomically valid cardiac shape. This warping procedure is carried out with a constrained variational autoencoder (cVAE) trained to learn a representation of valid cardiac shapes through a smooth, yet constrained, latent space. With this cVAE, we can project any implausible shape into the cardiac latent space and steer it toward the closest correct shape. We tested our framework on short-axis MRI as well as apical two and four-chamber view ultrasound images, two modalities for which cardiac shapes are drastically different. With our method, CNNs can now produce results that are both within the inter-expert variability and always anatomically plausible without having to rely on a shape prior.