Shyam Prakash

Prof. Shyam Prakash


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2022 in Public Health Nutrition
Verified
Journal Article
Open access
PDF file
AGAakriti Gupta
Aakriti Gupta
HSHarshpal Singh Sachdev
Harshpal Singh Sachdev
UKUmesh Kapil
Umesh Kapil
SPShyam Prakash
Shyam Prakash
RPRavindra Mohan Pandey
Ravindra Mohan Pandey
PLPriti Rishi Lal
Priti Rishi Lal
Objective: High burden of anaemia exists amongst rural adolescent girls in India. The objective of this study was to characterise anaemia in school going adolescent girls in rural Haryana, India.Design: Linear and multiple logistic regression analysis of data collected prior to an intervention trial was conducted. Participants were classified into anaemic (haemoglobin <12 g/dl) and non-anaemic group and were further classified into deficiencies of Fe, folate or vitamin B12, mixed, anaemia of other causes and inflammation.Setting: Three schools in Ballabgarh block of Faridabad District, Haryana, India.Participants: One hundered and ninety-eight non-anaemic and 202 anaemic adolescent girls (12–19 years).Results: Anaemic girls had 29·6 % Fe deficiency, 28·1 % folate or vitamin B12deficiency, 15·8 % mixed deficiency and 9·7 % acute inflammation. Anaemia of other causes was found in 16·8 % of the anaemic participants. Girls with Fe and isolated folate deficiency had 2·5 times and four times higher odds of developing anaemia, respectively, as compared with non-anaemic girls. Fe deficiency with no anaemia was found amongst 11 % non-anaemic girls. Non-anaemic girls had a high prevalence of combined deficiency of folate or vitamin B12(29·5 %) and acute inflammation (14·4 %).Conclusions: The current strategy of Fe and folic acid supplementation alone will not suffice for achieving the desired reduction in the prevalence of anaemia as unknown causes and anaemia of inflammation contribute to a substantial proportion of anaemia. Integrating other nutrition-specific components like improving water, sanitation and hygiene practices with the ongoing micronutrient supplementation program will comprehensively tackle anaemia. Unknown causes of anaemia warrant further research.

11 January 2023 in MethodsX
Verified
Journal Article
Open access
SPShyam Prakash
Shyam Prakash
PRPriyatma
Priyatma
RAR Aasarey
R Aasarey
PPP K Pandey
P K Pandey
PMP Mathur
P Mathur
SAS Arulselvi
S Arulselvi
SARS-CoV-2 is a public pandemic health concern globally. Nasopharyngeal and oropharyngeal swab samples are used for Covid-19 viral detection. Sample collection procedure was tedious and uncomfortable and unsuitable for biochemical and CBC analysis in swab samples. Biochemistry and CBC tests are key determinant in management of Covid-19 patients. We developed a LAMP test to detect viral RNA in blood samples. LAMP is required four specific primers targeting the internal transcribed S-region and loop primers for viral RNA amplification. RNA was extracted from blood samples by TRIzol method. LAMP reaction was performed at 60 °C for 1 hour and amplicons were visualized in HNB dye. No cross-reactivity was seen with HBV, HCV, and HIV infected sample. Out of 40 blood samples, 33 samples were positive for LAMP and Q-PCR analysis, one sample was positive for LAMP and negative for Q-PCR, two samples were negative for LAMP but positive for Q-PCR, and four blood samples were negative for LAMP and Q-PCR. LAMP method has an accuracy of 92.50%, with sensitivity and specificity of 94.28% and 80%, respectively. Thus, LAMP diagnostic test has proved reliable, fast, inexpensive and can be useful for detection where the limited resources available.•LAMP method is a potential tool for detection of SARS-CoV-2.•Blood samples are the key determinant for routine diagnostics as well as molecular diagnostics.•LAMP assay is an appropriate diagnostics method which offers greater simplicity, low cost, sensitivity, and specificity than other methods in molecular diagnostics.

15 April 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SPShyam Prakash
Shyam Prakash
RARam Aasarey
Ram Aasarey
MSMeenakshi Sharma
Meenakshi Sharma
SKShahid Khan
Shahid Khan
HIV infection has been a global public health threat and overall reported ~ 40 million deaths. Acquired immunodeficiency syndrome (AIDS) is attributed to the retroviruses (HIV-1/2), disseminated through various body fluids. The temporal progression of AIDS is in context to the rate of HIV-1 infection, which is twice as protracted in HIV-2 transmission. Q-PCR is the only available method that requires a well-developed lab infrastructure and trained personnel. Micro-PCR, a portable Q-PCR device, was developed by Bigtec Labs, Bangalore, India. It is simple, accurate, fast, and operationalised in remote places where diagnostic services are inaccessible in developing countries. This novel micro-PCR determines HIV-1 and HIV-2 viral load using a TruePrep™ extractor device for RNA isolation. Five ml blood samples were collected at the blood collection centre at AIIMS, New Delhi, India. Samples were screened for serology, and a comparison of HIV-1/2 RNA was done between qPCR and micro-PCR in the samples. The micro-PCR assay of HIV-RNA has compared well with those from real-time PCR (r = 0.99, i < 0.002). Micro-PCR has good inter and intra-assay reproducibility over a wide dynamic range (1.0 × 102–1.0 × 108 IU/ml). The linear dynamic range was 102–108 IU/ml. The clinical and analytical specificity of the assay was comparable, i.e., 100%. Intra-assay and inter-assay coefficients of variation ranged from 1.17% to 3.15% and from 0.02% to 0.46%, respectively. Moreover, due to the robust, simple, and empirical method, the Probit analysis has also been done for qPCR LODs to avoid uncertainties in target recoveries. The micro-PCR is reliable, accurate, and reproducible for early detection of HIV-1 and HIV-2 viral loads simultaneously. Thus, it can easily be used in the field and in remote places where quantification of both HIV-1/2 is not reachable.

20 June 2023 in Molecular and Cellular Biochemistry
Verified
Journal Article
Closed access
PDF file
MSManish Saroj
Manish Saroj
SPShyam Prakash
Shyam Prakash
NVNaval K Vikram
Naval K Vikram
ASAnoop Saraya
Anoop Saraya
PRPriyatma
Priyatma
SPShivam Pandey
Shivam Pandey

1 January 2014
Verified
Journal Article
Closed access
UKUmesh Kapil
Umesh Kapil
RPRavindra Mohan Pandey
Ravindra Mohan Pandey
SPShyam Prakash
Shyam Prakash
MKMadhulika Kabra
Madhulika Kabra
NSNeha Sareen
Neha Sareen
ABAjeet Singh Bhadoria
Ajeet Singh Bhadoria

19 February 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SPShweta Panwar
Shweta Panwar
RARam Aasarey
Ram Aasarey
RARaksha Anand
Raksha Anand
APAkanksha Priya
Akanksha Priya
SPShyam Prakash
Shyam Prakash
SJSandeep Kumar Jha
Sandeep Kumar Jha
A portable optical biosensor was designed for non-invasive detection of glucose through saliva. In this approach, a biodegradable glucose test strip was fabricated by 3D printing to create a fluidic groove and was filled with a cellulose based sieving infill matrix, onto which, glucose oxidase (GOD)-peroxidase (POD) and O-dianisidine chromogenic dye were co-immobilized. The enzymatic reaction with saliva samples containing glucose produced H2O2 as an intermediate product with which dye reacted, leading to a colour change to reddish-brown in the detection zone, which was then quantified by the developed electronic meter. The meter featured an optically isolated section within the chassis for inserting the test strip and sample to prevent interference from external factors such as wind and ambient light. The biosensor exhibited a broad detection range spanning 21.7 to 225 mg/dL of glucose concentration, with a sensitivity of 12.58 sensor count/mgdL-1 and a limit of detection (LOD) of 21.7 mg/dL within a response time of 2.5 minutes. The device and the strips were validated with clinical samples, comparing salivary glucose levels (SGL) with blood glucose levels (BGL) using a commercial glucometer. A good correlation was observed between SGL and BGL for diabetic/pre-diabetic subjects under fasting and post-prandial conditions as 0.99, 0.98 (p-values of 0.009 and 0.006); and for non-diabetic as 0.53 and 0.95 (p-values of 0.014, 0.007) respectively. The device also passed Clarke's error grid analysis, indicating its clinical acceptability. This low-cost, standalone, user-friendly device has thus the potential to revolutionize the self-monitoring of glucose in painless manner.