Galaxy groups host the majority of matter and more than half of all the galaxies in the Universe. Their hot ( K), X-ray emitting intra-group medium (IGrM) reveals emission lines typical of many elements synthesized by stars and supernovae. Because their gravitational potentials are shallower than those of rich galaxy clusters, groups are ideal targets for studying, through X-ray observations , feedback effects, which leave important marks on their gas and metal contents. Here, we review the history and present status of the chemical abundances in the IGrM probed by X-ray spectroscopy. We discuss the limitations of our current knowledge, in particular due to uncertainties in the modeling of the Fe-L shell by plasma codes, and coverage of the volume beyond the central region. We further summarize the constraints on the abundance pattern at the group mass scale and the insight it provides to the history of chemical enrichment. Parallel to the observational efforts, we review the progress made by both cosmological hydrodynamical simulations and controlled high-resolution 3D simulations to reproduce the radial distribution of metals in the IGrM, the dependence on system mass from group to cluster scales, and the role of AGN and SN feedback in producing the observed phenomenology. Finally, we highlight future prospects in this field, where progress will be driven both by a much richer sample of X-ray emitting groups identified with eROSITA, and by a revolution in the study of X-ray spectra expected from micro-calorimeters onboard XRISM and ATHENA.
13 April 2018 in Journal of Astronomical Telescopes, Instruments, and Systems
The Hitomi mission,1,2 formerly known as Astro-H, was launched from Tanegashima Space Center, Japan, on February 17, 2016. It carried the Soft X-ray Spectrometer (SXS),3 a microcalorimeter array cooled to 50 mK to provide high-resolution nondispersive spectroscopy from 0.3 to 12 keV. The instrument enabled plasma diagnostics in this waveband, which includes the K-shell transitions of all astrophysically abundant elements from C through Ni, as well as the L-shell transitions of several elements, including Fe. The SXS was commissioned shortly after launch and began making astronomical measurements4 just days into the mission.5 The instrument performed as expected until the untimely loss of the mission on March 26, 2016.
1 October 2025 in Journal of Astronomical Telescopes, Instruments, and Systems
We present an overview of the design and in-flight performance of the Resolve soft X-ray spectrometer on the X-Ray Imaging and Spectroscopy Mission that was successfully launched on September 7, 2023, on a JAXA H-IIA rocket from the Tanegashima Space Center of Japan. The instrument has a 36-pixel array of microcalorimeters, 35 of which are at the focus of a high-throughput grazing-incidence X-ray mirror. The instrument has achieved its required operational base temperature of 0.05 K and a spectral resolution of 4.5 eV (FWHM) at 6 keV. The cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate with and without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications are that the cryogen lifetime may reach 6 years with a cryogen-free mode thereafter. A series of onboard X-ray calibration sources produces energy scale calibration lines simultaneously while observing celestial sources. The overall design and in-flight performance of Resolve are described.
14 August 2025 in Journal of Astronomical Telescopes, Instruments, and Systems
The Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM) consists of an array of 6×6 silicon-thermistor microcalorimeters cooled down to 50 mK and a high-throughput X-ray mirror assembly (XMA) with a focal length of 5.6 m. XRISM is a recovery mission of ASTRO-H/Hitomi, and the Resolve instrument is a rebuild of the ASTRO-H Soft X-ray spectrometer (SXS) and the Soft X-ray Telescope (SXT) that achieved energy resolution of ∼5 eV FWHM on orbit, with several important changes based on lessons learned from ASTRO-H. The flight models of the Dewar and the electronics boxes were fabricated, and the instrument test and calibration were conducted in 2021. By tuning the cryocooler frequencies, energy resolution better than 4.9 eV FWHM at 6 keV was demonstrated for all 36 pixels and high-resolution grade events, as well as energy-scale accuracy better than 2 eV up to 30 keV. The immunity of the detectors to microvibration, electrical conduction, and radiation was evaluated. The instrument was delivered to the spacecraft system in April 2022. The XMA was tested and calibrated separately. Its angular resolution is 1.27′, and the effective area of the mirror itself is 570 cm2 at 1 keV and 424 cm2 at 6 keV. We report the design and the major changes from the ASTRO-H SXS, the integration, and the results of the instrument test.
18 August 2025 in Publications of the Astronomical Society of Japan
We report on a detailed spectroscopic study of the gas dynamics and hydrostatic mass bias of the galaxy cluster Abell 2029, utilizing high-resolution observations from XRISM Resolve. Abell 2029, known for its cool core and relaxed X-ray morphology, provides an excellent opportunity to investigate the influence of gas motions beyond the central region. Expanding upon prior studies that revealed low turbulence and bulk motions within the core, our analysis covers regions out to the scale radius $R_{2500}$ (670 kpc) based on three radial pointings extending from the cluster center toward the northern side. We obtain accurate measurements of bulk and turbulent velocities along the line of sight. The results indicate that non-thermal pressure accounts for no more than 2% of the total pressure at all radii, with a gradual decrease outward. The observed radial trend differs from many numerical simulations, which often predict an increase in non-thermal pressure fraction at larger radii. These findings suggest that deviations from hydrostatic equilibrium are small, leading to a hydrostatic mass bias of around 2% across the observed area.
20 August 2025 in Publications of the Astronomical Society of Japan
We present high-resolution X-ray spectroscopic observations of the Ophiuchus galaxy cluster core using the X-Ray Imaging and Spectroscopy Mission (XRISM) satellite. Despite previous observations revealing multiple cold fronts and dynamical disturbances in the cluster core, our XRISM observations show low gas velocity dispersions of $\sigma _{\rm v} = 115\pm 7$ km s$^{-1}$ in the inner region ($\lesssim$25 kpc) and $\sigma _{\rm v} = 186\pm 9$ km s$^{-1}$ in the outer region ($\sim$25–50 kpc). The gas temperatures are $kT = 5.8\pm 0.2$ and $8.4\pm 0.2$ keV for the inner and outer regions, respectively, with metal abundances of $Z = 0.75\pm 0.03$ Z$_{\odot }$ (inner) and $0.44\pm 0.02$ Z$_{\odot }$ (outer). The measured velocity dispersions correspond to non-thermal pressure fractions of only $1.4\pm 0.2$% (inner) and $2.5\pm 0.2$% (outer), indicating highly subsonic turbulence. Our analysis of the bulk gas motion indicates that the gas in the inner region is nearly at rest relative to the central galaxy ($|v_{\rm bulk}|=8\pm 7$ km s$^{-1}$), while the outer region exhibits a moderate motion of $|v_{\rm bulk}|=104\pm 7$ km s$^{-1}$. Assuming the velocity dispersion arises from turbulent motions, the turbulent heating rate is $\sim$40% of the radiative cooling rate, although there is some uncertainty. This suggests that the heating and cooling of the gas are not currently balanced. The activity of the central active galactic nucleus has apparently weakened. The sloshing motion that created the cold fronts may now be approaching a turning point at which the velocity is minimum. Alternatively, the central galaxy and the associated hot gas could be moving nearly parallel to the plane of the sky.