Introduction The aim of this study was to evaluate the efficacy and vision-threatening complications of brachytherapy with ruthenium-106 (106Ru) plaque to treat uveal melanoma. Material and methods A literature review was performed based on results from searching PubMed, Embase, Web of...
1 August 2021 in Critical Reviews in Oncology/Hematology
Purpose : Intra-fractional organs at risk (OARs) deformations can lead to dose variation during image-guided adaptive brachytherapy (IGABT). The aim of this study was to modify the final accepted brachytherapy treatment plan to dosimetrically compensate for these intra-fractional...
10 August 2022 in Journal of Applied Clinical Medical Physics
Purpose: This study aimed to evaluate the feasibility of defining an in vivo dosimetry (IVD) protocol as a patient‐specific quality assurance (PSQA) using the bead thermoluminescent dosimeters (TLDs) for point and 3D IVD during brachytherapy (BT) of gynecological (GYN) cancer using 60Co high‐dose‐rate (HDR) source.Methods: The 3D in vivo absorbed dose verification within the rectum and bladder as organs‐at‐risk was performed by bead TLDs for 30 GYN cancer patients. For rectal wall dosimetry, 80 TLDs were placed in axial arrangements around a rectal tube covered with a layer of gel. Ten beads were placed inside the Foley catheter to get the bladder‐absorbed dose. Beads TLDs were localized and defined as control points in the treatment planning system (TPS) using CT images of the patients. Patients were planned and treated using the routine BT protocol. The experimentally obtained absorbed dose map of the rectal wall and the point dose of the bladder were compared to the TPSs predicted absorbed dose at these control points.Results: Relative difference between TPS and TLDs results were −8.3% ± 19.5% and −7.2% ± 14.6% (1SD) for rectum‐ and bladder‐absorbed dose, respectively. Gamma analysis was used to compare the calculated with the measured absorbed dose maps. Mean gamma passing rates of 84.1%, 90.8%, and 92.5% using the criteria of 3%/2 mm, 3%/3 mm, and 4%/2 mm were obtained, respectively. Eventually, a “considering level” of at least 85% as pass rate with 4%/2‐mm criteria was recommended.Conclusions: A 3D IVD protocol employing bead TLDs was presented to measure absorbed doses delivered to the rectum and bladder during GYN HDR‐BT as a reliable PSQA method. 3D rectal absorbed dose measurements were performed. Differences between experimentally measured and planned absorbed dose maps were presented in the form of a gamma index, which may be used as a warning for corrective action.
1 November 2022 in Reports of Practical Oncology and Radiotherapy
Background:This study was conducted to evaluate the effect of brachytherapy (BT) customized mold [Condensation silicone elastomer (ProtesilTM)] and its thickness on the dose distribution pattern of deep nonmelanoma skin cancers (NMSC).Materials and methods: Four blocks of mold material were constructed in 5, 10, 15, and 20 mm thickness and 100 x 100 mm2 area by a plastic cast. The high dose rate (HDR) plus treatment planning system (TPS) (Version 3, Eckert & Ziegler BEBIG Gmbh, Berlin, Germany) with a 60Co source (model: Co0.A86, EZAG BEBIG, Berlin, Germany) as an high dose rate brachytherapy (HDR-BT) source was used. Solid phantom and MOSFETTM and GAFCHROMICTM EBT3 film dosimeters were used for experimen-tal dosimetry of the different thicknesses (up to 20 mm) of BT customized mold. Skin dose and dose to different depths were evaluated.Result: The TPS overestimated the calculated dose to the surface. Skin dose can be reduced from 250% to 150% of the pre-scription dose by increasing mold thickness from 5 mm to 20 mm. There was a 7.7% difference in the calculated dose by TPS and the measured dose by MOSFET. There was a good agreement between film dosimetry, MOSFET detector, and TPS' results in depths less than 5 mm. Conclusion: Each BT department should validate any individualized material chosen to construct the customized surface BT mold. Increasing the mold thickness can treat lesions without overexposing the skin surface. Superficial BT can be recom-mended as an appropriate treatment option for some deep NMSC lesions (up to 20 mm) with pre-planning considerations employing thicker molds.Key words: HDR-BT; mold; nonmelanoma skin cancer; dosimetry