Bone substitutes have been applied to treat osseous defects for a long time. To prevent implant related infection (IRI) and enhance bone healing functionalized biomaterials, antibiotics and osteoinductive substances have been introduced. This study gives an overview of the current available surface-coated bone substitutes and provides an outlook for future perspectives.
9 December 2020 in Zeitschrift für Orthopädie und Unfallchirurgie
Background Due to the lack of specificity of conventional diagnostic tools, the prediction of periprosthetic joint infections (PJI) remains challenging. The purpose of this study was to evaluate the accuracy of synovial fluid neopterin, presepsin, and TNF-α as diagnostic parameters and to compare it to the biomarkers recommended in the 2018 definition of periprosthetic hip and knee infection. Methods Between August 2018 and July 2019, a prospective cohort study was conducted in 80 patients with painful hip, shoulder, and knee arthroplasty. In addition to medical history, clinical and laboratory data were gathered. PJI was diagnosed based on the 2018 definition of periprosthetic hip and knee infection. Synovial joint fluid was analyzed for biomarker measurement using standard quantitative enzyme immunoassay kits. Results Fifty-three patients (66%) were classified as the aseptic group and twenty-seven patients (34%) as the PJI group. The mean levels of synovial fluid neopterin were significantly higher (p < 0.01) in the PJI group than those in the aseptic group (aseptic 8.3 ± 6.9 vs. PJI 20.9 ± 21.4 nmol/L). The average values of synovial fluid TNF-α and presepsin were not significantly higher in the PJI group than those in the aseptic group (presepsin: aseptic 0.13 ± 0.19 vs. PJI 0.11 ± 0.32 ng/mL, p = 0.08; TNF-α: aseptic 6.6 ± 7.3 vs. PJI 46.3 ± 123.2 pg/mL, p = 0.17). Synovial fluid neopterin was 59% specific and 74% sensitive with a cut-off value of 7.2 nmol/L. The sensitivity and specificity of synovial fluid TNF-α were 63 and 51% with a cut-off value of 3.9 pg/mL. Synovial fluid presepsin was 51% specific and 29% sensitive with a cut-off value above 0.06 ng/mL. Conclusion Synovial fluid neopterin appears to a reliable diagnostic marker for detection of PJI. In contrast, synovial fluid TNF-α and presepsin are not suitable to exclude or diagnose PJI.
During total joint replacement, high concentrations of mesenchymal stromal cells (MSCs) are released at the implantation site. They can be found in cell–tissue composites (CTC) that are regularly removed by surgical suction. A surgical vacuum suction handle was filled with bone substitute granules, acting as a filter allowing us to harvest CTC. The purpose of this study was to investigate the osteopromotive potential of CTC trapped in the bone substitute filter material during surgical suction. In the course of 10 elective total hip and knee replacement surgeries, β-tricalcium-phosphate (TCP) and cancellous allograft (Allo) were enriched with CTC by vacuum suction. Mononuclear cells (MNC) were isolated from the CTC and investigated towards cell proliferation and colony forming unit (CFU) formation. Furthermore, MSC surface markers, trilineage differentiation potential and the presence of defined cytokines were examined. Comparable amounts of MNC and CFUs were detected in both CTCs and characterized as MSC‰ of MNC with 9.8 ± 10.7‰ for the TCP and 12.8 ± 10.2‰ for the Allo (p = 0.550). CTCs in both filter materials contain cytokines for stimulation of cell proliferation and differentiation (EGF, PDGF-AA, angiogenin, osteopontin). CTC trapped in synthetic (TCP) and natural (Allo) bone substitute filters during surgical suction in the course of a joint replacement procedure include relevant numbers of MSCs and cytokines qualified for bone regeneration.