Jianbo Lei

Prof. Dr. Jianbo Lei


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2023 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
YYYang Yang
Yang Yang
SMShuan Ma
Shuan Ma
GLGuanghua Liu
Guanghua Liu
TWTao Wang
Tao Wang
JLJianbo Lei
Jianbo Lei

16 January 2025 in Applied Surface Science
Verified
Journal Article
Closed access
YWYing Wang
Ying Wang
TLTongchun Li
Tongchun Li
ZGZhenjie Gu
Zhenjie Gu
ZYZupeng Yan
Zupeng Yan
RDRuifeng Di
Ruifeng Di
JLJianbo Lei
Jianbo Lei

24 May 2021 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
YXYelin Xia
Yelin Xia
ZHZhaozhen Huang
Zhaozhen Huang
HCHanning Chen
Hanning Chen
XLXiaodan Liang
Xiaodan Liang
JLJianbo Lei
Jianbo Lei

25 March 2022 in Optics & Laser Technology
Verified
Journal Article
Closed access
RDRuifeng Di
Ruifeng Di
JZJiaqi Zhang
Jiaqi Zhang
ZQZhu Qian
Zhu Qian
YFYan Fang
Yan Fang
HTHongfang Tian
Hongfang Tian
JLJianbo Lei
Jianbo Lei

1 October 2023 in 3D Printing and Additive Manufacturing
Verified
Journal Article
Closed access
YHYabao Hu
Yabao Hu
HCHanning Chen
Hanning Chen
XLXiaodan Liang
Xiaodan Liang
MJMo Jia
Mo Jia
JLJianbo Lei
Jianbo Lei
Two kinds of porous structure design strategies, ring-support (RS) and column-support (CS), are proposed for human implants. The accurate design of porosity is realized by adjusting the pore characteristics, such as strut diameter, pore diameter, and unit size. Porous specimens with porosity of 50%, 60%, 70%, and 80% were prepared by selective laser melting. The three-dimensional pore structure is basically consistent with the design characteristics, and the measured porosity is slightly lower than design value. The microstructure, microhardness, and friction and wear properties of the samples were studied. The results show that the performance along the scanning orientation is slightly better than that along the forming orientation. The compression and dynamic elastic modulus of porous specimens with different structures and porosities were analyzed. The CS porous with 60–80% porosity has suitable compressive strength and elastic modulus, which is close to that of human tissue, and effectively avoids the stress shielding phenomenon.

27 November 2021 in Applied Physics A
Verified
Journal Article
Closed access
PDF file
RDRuifeng Di
Ruifeng Di
ZQZhu Qian
Zhu Qian
YFYan Fang
Yan Fang
FTFanliang Tantai
Fanliang Tantai
HTHongfang Tian
Hongfang Tian
JLJianbo Lei
Jianbo Lei