Jeongkyun Kim

Mr. Jeongkyun Kim

Electronics and Telecommunications Research Institute
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Jeongkyun KimJeongkyun Kim
Jeongkyun Kim
Myung-Nam BaeMyung-Nam Bae
Myung-Nam Bae
KLKangbok Lee
Kangbok Lee
JKJae-Chul Kim
Jae-Chul Kim
Sang Gi HongSang Gi Hong
Sang Gi Hong
Osteopenia and sarcopenia can cause various senile diseases and are key factors related to the quality of life in old age. There is need for portable tools and methods that can analyze osteopenia and sarcopenia risks during daily life, rather than requiring a specialized hospital setting. Gait is a suitable indicator of musculoskeletal diseases; therefore, we analyzed the gait signal obtained from an inertial-sensor-based wearable gait device as a tool to manage bone loss and muscle loss in daily life. To analyze the inertial-sensor-based gait, the inertial signal was classified into seven gait phases, and descriptive statistical parameters were obtained for each gait phase. Subsequently, explainable artificial intelligence was utilized to analyze the contribution and importance of descriptive statistical parameters on osteopenia and sarcopenia. It was found that XGBoost yielded a high accuracy of 88.69% for osteopenia, whereas the random forest approach showed a high accuracy of 93.75% for sarcopenia. Transfer learning with a ResNet backbone exhibited appropriate performance but showed lower accuracy than the descriptive statistical parameter-based identification result. The proposed gait analysis method confirmed high classification accuracy and the statistical significance of gait factors that can be used for osteopenia and sarcopenia management.

4 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Jeongkyun KimJeongkyun Kim
Jeongkyun Kim
Myung-Nam BaeMyung-Nam Bae
Myung-Nam Bae
KLKang Bok Lee
Kang Bok Lee
Sang Gi HongSang Gi Hong
Sang Gi Hong
Sarcopenia can cause various senile diseases and is a major factor associated with the quality of life in old age. To diagnose, assess, and monitor muscle loss in daily life, 10 sarcopenia and 10 normal subjects were selected using lean mass index and grip strength, and their gait signals obtained from inertial sensor-based gait devices were analyzed. Given that the inertial sensor can measure the acceleration and angular velocity, it is highly useful in the kinematic analysis of walking. This study detected spatial-temporal parameters used in clinical practice and descriptive statistical parameters for all seven gait phases for detailed analyses. To increase the accuracy of sarcopenia identification, we used Shapley Additive explanations to select important parameters that facilitated high classification accuracy. Support vector machines (SVM), random forest, and multilayer perceptron are classification methods that require traditional feature extraction, whereas deep learning methods use raw data as input to identify sarcopenia. As a result, the input that used the descriptive statistical parameters for the seven gait phases obtained higher accuracy. The knowledge-based gait parameter detection was more accurate in identifying sarcopenia than automatic feature selection using deep learning. The highest accuracy of 95% was achieved using an SVM model with 20 descriptive statistical parameters. Our results indicate that sarcopenia can be monitored with a wearable device in daily life.

13 July 2019 in ETRI Journal
Verified
Journal Article
Open access
PDF file
Jeongkyun KimJeongkyun Kim
Jeongkyun Kim
MBMyung‐Nam Bae
Myung‐Nam Bae
KLKang Bok Lee
Kang Bok Lee
Sang Gi HongSang Gi Hong
Sang Gi Hong
Gait analysis is an effective clinical tool across a wide range of applications. Recently, inertial measurement units have been extensively utilized for gait analysis. Effective gait analyses require...

27 July 2023 in Expert Systems with Applications
Verified
Journal Article
Closed access
Jeongkyun KimJeongkyun Kim
Jeongkyun Kim
KLKangbok Lee
Kangbok Lee
SHSang Gi Hong
Sang Gi Hong

16 July 2025 in JMIR Medical Informatics
Verified
Journal Article
Open access
Jeongkyun KimJeongkyun Kim
Jeongkyun Kim
SMSujeong Mun
Sujeong Mun
SLSiwoo Lee
Siwoo Lee
Background: Wearable devices are increasingly used for monitoring health and detecting digital biomarkers related to chronic diseases such as metabolic syndrome (MetS). Although circadian rhythm disturbances are known to contribute to MetS, few studies have explored wearable-derived circadian biomarkers for MetS identification. Objective: This study aimed to detect and analyze sleep and circadian rhythm biomarkers associated with MetS using step count and heart rate data from wearable devices and to identify the key biomarkers using explainable artificial intelligence (XAI). Methods: Data were analyzed from 272 participants in the Korean Medicine Daejeon Citizen Cohort, collected between 2020 and 2023, including 88 participants with MetS and 184 without any MetS diagnostic criteria. Participants wore Fitbit Versa or Inspire 2 devices for at least 5 weekdays, providing minute-level heart rate, step count, and sleep data. A total of 26 indicators were derived, including sleep markers (midsleep time and total sleep time) and circadian rhythm markers (midline estimating statistic of rhythm, amplitude, interdaily stability, and relative amplitude). In addition, a novel circadian rhythm marker, continuous wavelet circadian rhythm energy (CCE), was proposed using continuous wavelet transform of heart rate signals. Statistical tests (t test and the Wilcoxon rank sum test) and machine learning models—Shapley Additive Explanations, explainable boosting machine, and tabular neural network—were applied to evaluate marker significance and importance. Results: Circadian rhythm markers, especially heart rate–based indicators, showed stronger associations with MetS than sleep markers. The newly proposed CCE demonstrated the highest importance for MetS identification across all XAI models, with significantly lower values observed in the MetS group (P<.001). Other heart rate–based markers, including relative amplitude and low activity period, were also identified as important contributors. Although sleep markers did not reach statistical significance, some were recognized as secondary predictors in XAI-based analyses. The CCE marker maintained a high predictive value even when adjusting for age, sex, and BMI. Conclusions: This study identified CCE and relative amplitude of heart rate as key circadian rhythm biomarkers for MetS monitoring, demonstrating their high importance across multiple XAI models. In contrast, traditional sleep markers showed limited significance, suggesting that circadian rhythm analysis may offer additional insights into MetS beyond sleep-related indicators. These findings highlight the potential of wearable-based circadian biomarkers for improving MetS assessment and management.

27 November 2024 in JMIR Preprints
Verified
Preprint
Open access
Jeongkyun KimJeongkyun Kim
Jeongkyun Kim
SMSujeong Mun
Sujeong Mun
SLSiwoo Lee
Siwoo Lee
BACKGROUND Digital biomarker detection using wearable devices is utilized as a solution for managing metabolic syndrome (MetS) in daily life. OBJECTIVE This study aimed to detect digital biomarkers based on sleep and circadian rhythm using step counts and heart rate data obtained from wearable devices and to analyze important biomarkers for MetS risk groups. METHODS Circadian rhythm markers based on heart rate and step counts were analyzed, including the newly proposed continuous wavelet circadian rhythm energy. The detected markers were analyzed for their contribution to MetS using SHapley Additive exPlanations, Explainable Boosting Machine, and Tabular Neural Network models. RESULTS Analysis of sleep and circadian rhythm biomarkers using statistical analysis and artificial intelligence methods revealed that circadian rhythm markers were more important for MetS than sleep markers. Among circadian rhythm markers, heart rate-based markers were found to be more important than step counts. The continuous wavelet circadian energy proposed in this study showed the highest contribution to MetS in the artificial intelligence analysis results. CONCLUSIONS The risk of MetS can be continuously identified and monitored in daily life by utilizing circadian rhythm markers.