The aim of this study is to investigate whether Serpin clade C (SERPINC1), E-selectin, P-selectin, Placental protein 13 (PP13), and Retinol-binding protein-4 (RBP4) levels in maternal serum were as...
1 December 2020 in Journal of Obstetrics and Gynaecology Research
Our purpose was to examine the level of knowledge and awareness about HPV (Human papillomavirus) infection, HPV vaccines, and cervical cancer of participants. This study was conducted at students and healthcare workers of Uskudar University as well as the healthcare workers of Umraniye Training and Research Hospital and patients admitted to the gynecology outpatient clinics. A 41-question survey was conducted that investigated the 700 participants’ demographic characteristics, HPV infection and cervical cancer status, and attitudes toward vaccination. 44.1% of the participants stated that they knew the cause of cervical cancer, 42.8% did not. 55.9% of those who went to regular doctor control, 38.5% of those who did not, knew that the HPV vaccine prevented warts and cervical cancer. 63.4% of men and 75.4% of women stated that they did not know whether the vaccine was effective against penile, anal and laryngeal cancer. All these were found to be statistically significant (P < .05). Lack of knowledge on vaccine protection, insufficient knowledge regarding HPV, prevalence of prejudices, and overall opinions about health are the most prevalent public health concerns in Turkey.
Objectives: The primary aim of this study was to evaluate fetal cardiac systolic and diastolic function using the tissue Doppler technique in pregnancies with complications of fetal growth restriction (FGR) and to examine the relationship between FGR with umbilical artery Doppler parameters and fetal cardiac function in complicated pregnancies. Material and methods: This study included 30 pregnant women with FGR complications and 46 pregnant women without FGR complications. Both groups were at 24–34 gestational weeks. Fetal cardiac examination was performed using pulsed Doppler and tissue Doppler imaging (TDI) in all pregnancies. In the analysis of myocardial tissue by tissue Doppler, the tracing obtained from the junction of the tricuspid valve annulus with the right ventricle was recorded by measuring the duration of the isovolumetric contraction wave (IVC), ejection time (ET), and isovolumetric relaxation time (IVR). Furthermore, we calculated the myocardial performance index (MPI) and then measured and recorded the early diastolic annular rate. Results: Based on the TDI studies, the mean IVC and IVR values were significantly longer and the ET values were significantly shorter in the study group than those in the control group. The study group also had significantly longer MPI measurements. Conclusions: Because TDI is a considerably more sensitive method than cardiac sonographic evaluation using pulsed Doppler, tissue Doppler parameters facilitate the detection of cardiac dysfunction at a relatively early stage. In addition, TDI and myocardial evaluation in fetuses with FGR can be noninvasively performed in clinical practice. Objectives: The primary aim of this study was to evaluate fetal cardiac systolic and diastolic function using the tissue Doppler technique in pregnancies with complications of fetal growth restriction (FGR) and to examine the relationship between FGR with umbilical artery Doppler parameters and fetal cardiac function in complicated pregnancies. Material and methods: This study included 30 pregnant women with FGR complications and 46 pregnant women without FGR complications. Both groups were at 24–34 gestational weeks. Fetal cardiac examination was performed using pulsed Doppler and tissue Doppler imaging (TDI) in all pregnancies. In the analysis of myocardial tissue by tissue Doppler, the tracing obtained from the junction of the tricuspid valve annulus with the right ventricle was recorded by measuring the duration of the isovolumetric contraction wave (IVC), ejection time (ET), and isovolumetric relaxation time (IVR). Furthermore, we calculated the myocardial performance index (MPI) and then measured and recorded the early diastolic annular rate. Results: Based on the TDI studies, the mean IVC and IVR values were significantly longer and the ET values were significantly shorter in the study group than those in the control group. The study group also had significantly longer MPI measurements. Conclusions: Because TDI is a considerably more sensitive method than cardiac sonographic evaluation using pulsed Doppler, tissue Doppler parameters facilitate the detection of cardiac dysfunction at a relatively early stage. In addition, TDI and myocardial evaluation in fetuses with FGR can be noninvasively performed in clinical practice.
10 April 2022 in Journal of Obstetrics and Gynaecology Research