The location of the terminal hinge axis of the temporomandibular joint is still a very wide-spread procedure in dentistry in order to replicate the movement in various articulator devices. Especially pantographic methods are claimed to provide accurate measurements and, additionally, are seen to be able to separate a pure rotation of the joint from a movement with an arbitrary combined shift and rotation. In the latter application, these methods were used in a lot of studies as a reference standard. The aim of this study was to analyze, whether common pantographic methods in general are able to distinguish between a pure rotation and a movement with rotational and translational portions. The mathematical proof of this analysis was done with theoretical kinematic considerations and compared with computer simulations. The results show for the first time that there exist combinations of rotational and translational movements of the temporomandibular joint which cannot be separated from pure rotational movements using actual pantographic methods. Even more, the consequence is a shifted location of the (combined) finite center (axis) of rotation in comparison to the true center (axis) of rotation: in case of a translational portion of only 1 mm, this is a displacement of around ±6 mm and, in case of 2 mm translation, a displacement of ±12 mm. This finding necessitates a critical reinterpretation of former studies using pantographic methods as a reference standard. Further, under some circumstances it may also affect the applicability of articulator concepts and the interpretation of functional signs.
This in vitro study aimed to evaluate the accuracy of seven intraoral scanners (IOSs) for full-arch impressions. Correlations among three evaluation parameters summarising three-dimensional (3D) difference values were also analysed. Custom-made complete-arch reference models were initially scanned using a reference scanner (ATOS III, Triple Scan MV60). Full-arch scans were then performed using seven IOSs (n = 20 each): Aoralscan 3, Emerald Green (EME), iTero 5D, Medit i900, Primescan (PRI), Primescan 2, and Trios 5. Conventional impressions (CONVs) (n = 20) were obtained and digitised using a laboratory scanner (inEOS X5). All data were exported as standard tessellation language files. Trueness and precision were determined using (90_10)/2-percentile values. Statistical analyses were performed using analysis of variance with Games-Howell post-hoc test and linear mixed-effects model. Correlations among absolute 80-percentile, absolute mean, and (90_10)/2-percentile were analysed using linear regression with Pearson's correlation coefficient. Trueness ranged from 24.5 ± 3.2 μm (CONV) to 95.0 ± 18.8 μm (EME), while precision ranged from 13.3 ± 2.6 μm (CONV) to 59.6 ± 22.4 μm (EME). CONV outperformed all IOSs. PRI showed the highest accuracy (trueness: 30.5 ± 5.3 μm, precision: 18.7 ± 5.6 μm). The evaluated parameters showed highly significant linear correlations (p < 0.001). All tested IOSs show full-arch deviations of <100 µm. The evaluation parameters are highly correlated, allowing for comparability. IOSs reach clinically acceptable accuracy values for full-arch impressions. However, high-precision CONVs still achieve the highest trueness and precision for full-arch impressions.
The purpose of this in vitro study was to compare the time efficiency of digital chairside and labside workflows with a conventional workflow for single-unit restorations. The time efficiency in this specific sense was defined as the time, which has to be spent in a dental office by a dental professional performing the relevant steps. A model with interchangeable teeth on position 36 was created. These teeth were differently prepared, responding to several clinical situations to perform single-unit restorations. Different manufacturing techniques were used: For the digital workflows, CEREC Omnicam (CER) and Trios 3 (TN/TI) were used. The conventional workflow, using a dual-arch tray impression technique, served as the control group. For the labside workflow (_L) and the conventional impression procedure (CO), the time necessary for the impressions and temporary restorations was recorded and served as operating time. The chairside workflow time was divided by the time for the entire workflow (_C) including scan, design, milling and finishing the milled restoration, and in the actual working time (_CW) leaving out the chairside milling of the restoration. Labside workflow time ranged from 9 min 27 s (CER_L) to 12 min 41 s (TI_L). Entire chairside time ranged from 43 min 35 s (CER_C) to 58 min 43 s (TI_C). Pure chairside working time ranged from 15 min 21 s (CER_CW) to 23 min 17 s (TI_CW). Conventional workflow time was 10 min 39 s (CO) on average. The digital labside workflow and the conventional workflow require a similar amount of time. The digital chairside workflow is more time consuming.
Evolutionary changes in vertebrates are linked to genetic alterations that often affect tooth crown shape, which is a criterion of speciation events. The Notch pathway is highly conserved between species and controls morphogenetic processes in most developing organs, including teeth. Epithelial loss of the Notch-ligand Jagged1 in developing mouse molars affects the location, size and interconnections of their cusps that lead to minor tooth crown shape modifications convergent to those observed along Muridae evolution. RNA sequencing analysis revealed that these alterations are due to the modulation of more than 2000 genes and that Notch signaling is a hub for significant morphogenetic networks, such as Wnts and Fibroblast Growth Factors. The modeling of these tooth crown changes in mutant mice, via a three-dimensional metamorphosis approach, allowed prediction of how Jagged1-associated mutations in humans could affect the morphology of their teeth. These results shed new light on Notch/Jagged1-mediated signaling as one of the crucial components for dental variations in evolution.