A subclade of connexins comprising Cx26, Cx30, and Cx32 are directly sensitive to CO2. CO2 binds to a carbamylation motif present in these connexins and causes their hemichannels to open. Cx26 may contribute to CO2-dependent regulation of breathing in mammals. Here, we show that the carbamylation motif occurs in a wide range of non-mammalian vertebrates and was likely present in the ancestor of all gnathostomes. While the carbamylation motif is essential for connexin CO2-sensitivity, it is not sufficient. In Cx26 of amphibia and lungfish, an extended C-terminal tail prevents CO2-evoked hemichannel opening despite the presence of the motif. Although Cx32 has a long C-terminal tail, Cx32 hemichannels open to CO2 because the tail is conformationally restricted by the presence of proline residues. The loss of the C-terminal tail of Cx26 in amniotes was an evolutionary innovation that created a connexin hemichannel with CO2-sensing properties suitable for the regulation of breathing.
Current available methods for the clinical diagnosis of urinary tract infection (UTI) rely on a urine dipstick test or culturing of pathogens. The dipstick test is rapid (available in 1–2 min), but has a low positive predictive value, while culturing is time-consuming and delays diagnosis (24–72 h between sample collection and pathogen identification). Due to this delay, broad-spectrum antibiotics are often prescribed immediately. The over-prescription of antibiotics should be limited, in order to prevent the development of antimicrobial resistance. As a result, there is a growing need for alternative diagnostic tools. This paper reviews applications of chemical-analysis instruments, such as gas chromatography–mass spectrometry (GC-MS), selected ion flow tube mass spectrometry (SIFT-MS), ion mobility spectrometry (IMS), field asymmetric ion mobility spectrometry (FAIMS) and electronic noses (eNoses) used for the diagnosis of UTI. These methods analyse volatile organic compounds (VOCs) that emanate from the headspace of collected urine samples to identify the bacterial pathogen and even determine the causative agent’s resistance to different antibiotics. There is great potential for these technologies to gain wide-spread and routine use in clinical settings, since the analysis can be automated, and test results can be available within minutes after sample collection. This could significantly reduce the necessity to prescribe broad-spectrum antibiotics and allow the faster and more effective use of narrow-spectrum antibiotics.
Sequence and structure comparisons between alpha and beta connexins, Cx43 and Cx26, revealed that Cx43 has a motif, the carbamylation motif, that confers CO 2 -sensitivity on a subset of beta connexins. By using a fluorescent dye loading assay, whole cell patch clamp recordings and real-time measurement of ATP release via GRAB ATP , we have demonstrated that Cx43 hemichannels open in a highly CO 2 -sensitive manner over the range 20–70 mmHg. Mutational analysis confirms that the equivalent residues to those in Cx26, known to be involved in mediating the effects of CO 2 on gating of hemichannels and gap junction channels, also mediate Cx43 hemichannel gating. These data predict that Cx43 will be partially open at resting physiological levels of PCO 2 . In acute mouse hippocampal slices, we have demonstrated a CO 2 -dependent enhancement of synaptic transmission that was blocked by the Cx43-selective mimetic peptide Gap26. Our data resolves an inconsistency in the literature between in vivo studies suggesting that Cx43 hemichannels are at least partially open at rest and in vitro studies performed in the absence of HCO 3- /CO 2 buffering that show Cx43 hemichannels are shut.