Nowadays, the irradiation methodology in proton therapy is switching from the use of passively scattered beams to active pencil beams due to the possibility of more conformal dose distributions. The dose rates of active pencil beams are much higher than those of passive beams. The purpose of this study was to investigate whether there is any difference in the biological effectiveness of these passive and active irradiation modes. The beam qualities of double scattering and pencil beam scanning were measured dosimetrically and simulated using the Monte Carlo code. Using the medulloblastoma cell line DAOY, we performed an in vitro comparison of the two modes in two positions along the dose–deposition curve plateau and inside the Bragg peak. We followed the clonogenic cell survival, apoptosis, micronuclei, and γH2AX assays as biological endpoints. The Monte Carlo simulations did not reveal any difference between the beam qualities of the two modes. Furthermore, we did not observe any statistically significant difference between the two modes in the in vitro comparison of any of the examined biological endpoints. Our results do not show any biologically relevant differences related to the different dose rates of passive and active proton beams.
The study of radiation fields around the cyclotron room was carried out for the Proton-Therapy-Center in Prague (Czech Republic). The 230 MeV proton cyclotron will be installed there as well as additional components located along the beampath. The ambient doses were computed by taking into account 3 major sources of secondary radiation (neutron and photon) – the cyclotron, energy degrader and its collimator. The fluxes of neutrons/photons produced by protons were computed using Monte Carlo code MCNPXTM 2.5.0. Energy and angular distributions were computed for various targets and proton beam energies. Different physical models of high-energy proton interactions were studied as well. The annual charge at the cyclotron exit was based on the “patient model” (distribution of treatment type) established for a similar therapy center in Essen (Germany). Calculated data were used as an approximation of the radiation field of the most significant sources of radiation (graphite degrader, tantalum collimator). Fluence-to-dose conversion factors from ICRP-74 were used for the annual dose equivalent evaluation. With these results, the shielding analysis in the Therapy-Center was performed in the context of the current legislation requirements.
1 November 2014 in Radiation Physics and Chemistry
The aim of this paper is to investigate the possibility of using detectors based on LaBr3(Ce) scintillation crystal as part of gamma spectrometry systems for field use and possibly as part of a monitoring network around nuclear power plants, i.e. whether LaBr3(Ce) detectors can follow the classical scintillation detectors based on NaI (Tl). For this purpose, the Monte Carlo simulation of the IPROL-1 probe response was performed in the simplified geometry of the radionuclides-contaminated atmosphere. A study shows that a LaBr3(Ce)-based probe is usable for this purpose and results are at least comparable to those with a conventional NaI (Tl)-based probe.
23 February 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
The aim of this work is to propose methodology for estimations the characteristics of the radiation fields (and derived quantities from the field of dosimetry and radiation protection) in knowledge of a distribution of radionuclides released into the main production unit (or just a containment) area after a nuclear reactor accident. For such task stochastic Monte Carlo method has been chosen. Because of dimensions and thick shielding (concrete) barriers in the facility, application of the variance reduction techniques has been necessary. Monte Carlo code Monaco in sequence MAVRIC (from package SCALE 6.2.3) with variance reduction techniques using CADIS methodology has been employed for designing the proposed methodology. Procedure has been tested on a simulation model of a main production unit described by inspiration from the block of a nuclear power plant with a VVER-1000 reactor (installed in the Czech Republic, Central Europe).