Dagmar S. Trachsel

Dr. Dagmar S. Trachsel

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2012 in Equine Veterinary Journal
Verified
Journal Article
Closed access
PDF file
ABA. Borchers
A. Borchers
PWPamela A. Anne Wilkins
Pamela A. Anne Wilkins
PMP. M. Marsh
P. M. Marsh
JAJ. E. Axon
J. E. Axon
JRJ. Read
J. Read
RBR. C. Boston
R. C. Boston

8 November 2010 in Equine Veterinary Journal
Verified
Journal Article
Closed access
PDF file
CBC. Bitschnau
C. Bitschnau
TWT. Wiestner
T. Wiestner
DTDagmar S. Trachsel
Dagmar S. Trachsel
JAJ. A. Auer
J. A. Auer
MWM. A. Weishaupt
M. A. Weishaupt

17 October 2017 in Frontiers in Veterinary Science
Verified
Journal Article
Open access
ALAugustin Lenoir
Augustin Lenoir
DTDagmar S. Trachsel
Dagmar S. Trachsel
MYMohamed Younes
Mohamed Younes
EBEric Barrey
Eric Barrey
CRCéline ROBERT
Céline ROBERT
Analysis of the heart rate variability (HRV) gains more and more importance in the assessment of training practice and welfare in equine industry. It relies on mathematical analyses of reliably and accurately measured variations in successive inter-beat intervals, measured as RR intervals. Nowadays, the RR intervals can be obtained through two different techniques: a heart rate meter (HRM) or an electrocardiogram (ECG). The agreement and reliability of these devices has not been fully assessed, especially for recordings during exercise. The purpose of this study was to assess the agreement of two commercially available devices using the two mentioned techniques (HRM vs ECG) for HRV analysis during a standardized exercise test. Simultaneous recordings obtained during light exercise and during canter with both devices were available for 36 horses. Data were compared using a Bland-Altman analysis and the Lin’s coefficient. The agreement between the assessed HRV measures from the data obtained from the ECG and HRM was acceptable only for the mean RR interval and the mean heart rate. For the other studied measures (SDNN, RMSSD, SD1, SD2, LF, HF) the agreement between the devices was too poor for them to be considered as interchangeable in these recording conditions. The agreement tended also to be worse when speed of the exercise increased. Therefore, it is necessary to be careful when interpreting and comparing results of HRV analysis during exercise, as the results will depend upon recording devices. Furthermore, corrections and data processing included in the software of the devices affect largely the output used in the subsequent HRV analysis; this must be considered in the choice of the device.

8 November 2010 in Equine Veterinary Journal
Verified
Journal Article
Closed access
PDF file
DTDagmar S. Trachsel
Dagmar S. Trachsel
CBC. Bitschnau
C. Bitschnau
NWN. Waldern
N. Waldern
MWM. A. Weishaupt
M. A. Weishaupt
CSColin C Schwarzwald
Colin C Schwarzwald

25 January 2022 in Viruses
Verified
Journal Article
Open access
PDF file
FBFelicitas Bergmann
Felicitas Bergmann
DTDagmar S. Trachsel
Dagmar S. Trachsel
SSSabita Stöckle
Sabita Stöckle
JSJoke Bernis Sierra
Joke Bernis Sierra
SLStephan Lübke
Stephan Lübke
UZUte Ziegler
Ute Ziegler
Following the introduction of the West Nile virus (WNV) into eastern Germany in 2018, increasing infections have been diagnosed in birds, equines, and humans over time, while the spread of WNV into western Germany remained unclear. We screened 437 equine sera from 2018 to 2020, excluding vaccinated horses, collected from convenience sampled patients in the eastern and western parts of Germany, for WNV-specific antibodies (ELISAs followed by virus/specific neutralization tests) and genomes (RT-qPCRs). Clinical presentations, final diagnoses, and demographic data were also recorded. In the eastern part, a total of eight horses were found WNV seropositive in 2019 (seroprevalence of 8.16%) and 27 in 2020 (13.77%). There were also two clinically unsuspected horses with WNV-specific antibodies in the western part from 2020 (2.63%), albeit travel history-related infections could not be excluded. None of the horse sera contained WNV-specific genomes. Eight horses in eastern Germany carried WNV-IgM antibodies, but only four of these showed typical clinical signs. These results underline the difficulty of detecting a WNV infection in a horse solely based on clinical signs. Thus, WNV circulation is established in the horse population in eastern Germany, but not yet in the western part.

16 May 2013 in Journal of Veterinary Cardiology
Verified
Journal Article
Closed access
DTDagmar S. Trachsel
Dagmar S. Trachsel
CSColin C Schwarzwald
Colin C Schwarzwald
CBCaroline Bitschnau
Caroline Bitschnau
BGBeat Grenacher
Beat Grenacher
MWMichael A. Weishaupt
Michael A. Weishaupt