Jie Xue

Prof. Jie Xue


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2019 in Neuro-Oncology
Verified
Journal Article
Open access
PDF file
JXJie Xue
Jie Xue
BWBao Wang
Bao Wang
YMYang Ming
Yang Ming
XLXuejun Liu
Xuejun Liu
ZJZekun Jiang
Zekun Jiang
DLDengwang Li
Dengwang Li
Three-dimensional T1 magnetization prepared rapid acquisition gradient echo (3D-T1-MPRAGE) is preferred in detecting brain metastases (BM) among MRI. We developed an automatic deep learning–based detection and segmentation method for BM (named BMDS net) on 3D-T1-MPRAGE images and evaluated its performance. The BMDS net is a cascaded 3D fully convolution network (FCN) to automatically detect and segment BM. In total, 1652 patients with 3D-T1-MPRAGE images from 3 hospitals (n = 1201, 231, and 220, respectively) were retrospectively included. Manual segmentations were obtained by a neuroradiologist and a radiation oncologist in a consensus reading in 3D-T1-MPRAGE images. Sensitivity, specificity, and dice ratio of the segmentation were evaluated. Specificity and sensitivity measure the fractions of relevant segmented voxels. Dice ratio was used to quantitatively measure the overlap between automatic and manual segmentation results. Paired samples t-tests and analysis of variance were employed for statistical analysis. The BMDS net can detect all BM, providing a detection result with an accuracy of 100%. Automatic segmentations correlated strongly with manual segmentations through 4-fold cross-validation of the dataset with 1201 patients: the sensitivity was 0.96 ± 0.03 (range, 0.84–0.99), the specificity was 0.99 ± 0.0002 (range, 0.99–1.00), and the dice ratio was 0.85 ± 0.08 (range, 0.62–0.95) for total tumor volume. Similar performances on the other 2 datasets also demonstrate the robustness of BMDS net in correctly detecting and segmenting BM in various settings. The BMDS net yields accurate detection and segmentation of BM automatically and could assist stereotactic radiotherapy management for diagnosis, therapy planning, and follow-up.

1 November 2019 in Knowledge-Based Systems
Verified
Journal Article
Closed access
JXJie Xue
Jie Xue
SYShuo Yan
Shuo Yan
JQJianhua Qu
Jianhua Qu
FQFeng Qi
Feng Qi
CQChenggong Qiu
Chenggong Qiu
XLXiyu Liu
Xiyu Liu

1 April 2021 in Medical Image Analysis
Verified
Journal Article
Closed access
YWYuan Wang
Yuan Wang
GGGuanzhong Gong
Guanzhong Gong
DKDeting Kong
Deting Kong
QLQi Li
Qi Li
JDJinpeng Dai
Jinpeng Dai
JXJie Xue
Jie Xue

5 November 2022 in Neural Networks
Verified
Journal Article
Closed access
QLQi Li
Qi Li
XLXiyu Liu
Xiyu Liu
YHYiming He
Yiming He
DLDengwang Li
Dengwang Li
JXJie Xue
Jie Xue

1 September 2020 in Applied Soft Computing
Verified
Journal Article
Closed access
JXJie Xue
Jie Xue
JHJinyan Hu
Jinyan Hu
YWYuan Wang
Yuan Wang
DKDeting Kong
Deting Kong
SYShuo Yan
Shuo Yan
XLXiyu Liu
Xiyu Liu

19 June 2018 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
JXJie Xue
Jie Xue
ACAcner Camino
Acner Camino
SBSteven T. Bailey
Steven T. Bailey
XLXiyu Liu
Xiyu Liu
DLDengwang Li
Dengwang Li
YJYali Jia
Yali Jia
Detecting and quantifying the size of choroidal neovascularization (CNV) is important for the diagnosis and assessment of neovascular age-related macular degeneration. Depth-resolved imaging of the retinal and choroidal vasculature by optical coherence tomography angiography (OCTA) has enabled the visualization of CNV. However, due to the prevalence of artifacts, it is difficult to segment and quantify the CNV lesion area automatically. We have previously described a saliency algorithm for CNV detection that could identify a CNV lesion area with 83% accuracy. However, this method works under the assumption that the CNV region is the most salient area for visual attention in the whole image and consequently, errors occur when this requirement is not met (e.g. when the lesion occupies a large portion of the image). Moreover, saliency image processing methods cannot extract the edges of the salient object very accurately. In this paper, we propose a novel and automatic CNV segmentation method based on an unsupervised and parallel machine learning technique named density cell-like P systems (DEC P systems). DEC P systems integrate the idea of a modified clustering algorithm into cell-like P systems. This method improved the accuracy of detection to 87.2% on 22 subjects and obtained clear boundaries of the CNV lesions.