Emma Hooijberg

Prof. Emma Hooijberg

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2019 in Veterinary Clinical Pathology
Verified
Journal Article
Closed access
PDF file
JAJill E. Arnold
Jill E. Arnold
MCMelinda S. Camus
Melinda S. Camus
KFKathleen Freeman
Kathleen Freeman
LGLuca Giori
Luca Giori
EHEmma Hooijberg
Emma Hooijberg
JCJennifer R. Cook
Jennifer R. Cook

1 September 2014 in Journal of Veterinary Internal Medicine
Verified
Journal Article
Open access
PDF file
EHEmma Hooijberg
Emma Hooijberg
René van den HovenRené van den Hoven
René van den Hoven
ATA. Tichy
A. Tichy
ISI. Schwendenwein
I. Schwendenwein
Background: A wide spectrum of laboratory tests is available to aid diagnosis and classification of equine inflammatory disease. Objectives: To compare diagnostic efficacy and combined predictive capability of the myeloperoxidase index (MPXI), and plasma fibrinogen, iron and serum amyloid A (SAA) concentrations for the diagnosis of inflammation. Animals: Twenty-six hospitalized horses with systemic inflammation (SI), 114 with local inflammation (LI) and 61 healthy horses or those with noninflammatory disease (NI) were included. Methods: A retrospective study was performed; clinicopathologic data from horses were compared between groups. Receiver-operator characteristic (ROC) curves were used to evaluate diagnostic efficacy; classification and regression tree analysis (CART) and logistic regression analysis were used to generate diagnostic algorithms. Results: Horses with SI had significantly higher SAA than horses with LI (P = .007) and NI (P < .001) and lower iron concentrations than horses with LI (P < .001) and NI (P < .001). Fibrinogen concentration was higher in horses with inflammation than in those without inflammation (P = .002). There was no difference between the SI and LI groups. White blood cell count, neutrophil count and MPXI were similar between groups. SAA had the highest accuracy for diagnosing inflammation (area under ROC curve [AUC], 0.83 ± 0.06) and iron and SAA concentration had the highest accuracy for differentiating SI from LI (AUC, 0.80 ± 0.09 and 0.73 ± 0.10 respectively). Predictive modeling failed to generate useful algorithms and classification of cases was moderate. Conclusions and Clinical Importance: Very high SAA and low iron concentrations may reflect SI, but diagnostic guidelines based on quantitative results of inflammatory markers could not be formulated.

23 April 2012 in Journal of Veterinary Diagnostic Investigation
Verified
Journal Article
Open access
PDF file
EHEmma Hooijberg
Emma Hooijberg
ELErnst Leidinger
Ernst Leidinger
KFKathleen P. Freeman
Kathleen P. Freeman
Error recording and management is an integral part of a clinical laboratory quality management system. Analysis and review of recorded errors lead to corrective and preventive actions through modification of existing processes and, ultimately, to quality improvement. Laboratory errors can be divided into preanalytical, analytical, and postanalytical errors depending on where in the laboratory cycle the errors occur. The purpose of the current report is to introduce an error management system in use in a veterinary diagnostic laboratory as well as to examine the amount and types of error recorded during the 8-year period from 2003 to 2010. Annual error reports generated during this period by the error recording system were reviewed, and annual error rates were calculated. In addition, errors were divided into preanalytical, analytical, postanalytical, and “other” categories, and their frequency was examined. Data were further compared to that available from human diagnostic laboratories. Finally, sigma metrics were calculated for the various error categories. Annual error rates per total number of samples ranged from 1.3% in 2003 to 0.7% in 2010. Preanalytical errors ranged from 52% to 77%, analytical from 4% to 14%, postanalytical from 9% to 21%, and other error from 6% to 19% of total errors. Sigma metrics ranged from 4.1 to 4.7. All data were comparable to that reported in human clinical laboratories. The incremental annual reduction of error shows that use of an error management system led to quality improvement.

1 January 2012 in Tierärztliche Praxis Ausgabe K: Kleintiere / Heimtiere
Verified
Journal Article
Closed access
PDF file
MLM. Leschnik
M. Leschnik
EHEmma Hooijberg
Emma Hooijberg
ATA. Tichy
A. Tichy
ELE. Leidinger
E. Leidinger
GKG. Kirtz
G. Kirtz
Summary: Objective: Haematological changes in dogs and climatic conditions favourable for the vector may assist in the quick in-house diagnosis of canine babesiosis. Material and methods: Blood samples from 358 dogs suspected to have canine babesiosis were evaluated. The diagnosis was confirmed in 113 dogs by detection of Babesia canis by microscopic examination of a stained blood smear using the concentration line technique. Results: Thrombocytopenia was present in all 113 dogs. Red blood cell count, packed cell volume and haemoglobin values were below the reference range in 62.8%, 61.1% and 46.0% of affected dogs, respectively. An increased reticulocyte count was apparent in five Babesia canis-positive dogs. Leukopenia, lymphopenia, neutropenia and monocytosis were present in 54.9%, 47.8%, 30.4% and 6.5% of the dogs, respectively. Evaluating haematological parameters by CARTanalysis revealed a predictive model (accuracy = 93.5%) for canine babesiosis, when using the leucocyte, thrombocyte, and reticulocyte count. Climatic conditions present at the most probable time of Babesia canis-infection accounted for biseasonal occurrence. Changes of climatic factors during the year influence the vector activity and in conclusion should highlight babesiosis in the ranking of differentials for veterinarians. Conclusion: The results demonstrate that a tentative diagnosis of canine babesiosis can be made based on typical haematological changes. The results recorded match well with the seasonality of the tick vector and were confirmed here by the month of sample submission.

1 September 2014 in Journal of Veterinary Internal Medicine
Verified
Journal Article
Open access
PDF file
EFE. Furman
E. Furman
ELE. Leidinger
E. Leidinger
EHEmma Hooijberg
Emma Hooijberg
NBN. Bauer
N. Bauer
GBG. Beddies
G. Beddies
AMA. Moritz
A. Moritz
Background: Frequency and classification of anemia in terms of regeneration status and erythrocyte indices are not well described in cats. Objective: To determine frequency and regenerative status of anemia in samples from adult cats, to assess the sensitivity and specificity of macrocytosis and hypochromasia for detecting regenerative anemia (RA), and to evaluate the association of anemia with increased serum creatinine concentration (SC). Study Population: Laboratory records from 30,503 blood samples from cats (2003–2011). Methods: Clinicopathologic data reviewed retrospectively. Anemia defined as hematocrit (Ht) ≤27%, red blood cell count (RBC) ≤5.5 × 106/μL and hemoglobin (Hb) ≤9.0 g/dL. RA defined by manual absolute reticulocyte count >50 × 103/μL. Macrocytosis was defined as mean corpuscular volume (MCV) >55 fL and hypochromasia as mean corpuscular hemoglobin concentration (MCHC) <31 g/dL. Cutoff for increased serum creatinine concentration was 1.6 mg/dL. Results: Overall, 1,098 of 30,503 blood samples (3.6%) from cats fulfilled criteria for anemia, 633 of 1,098 (57.7%) classified as nonregenerative (NRA) and 465 of 1,098 (42.3%) as regenerative. RBC, Ht, and Hb were significantly lower in the RA compared to NRA group (P < .05). Sensitivity and specificity of the combined high MCV and low MCHC to detect samples with RA were 19.5 and 90.7%. SC was increased in 572 of the 1,098 anemic samples (52.1%) and in 11,121 of 29,405 of nonanemic samples (37.8%). Conclusions and Clinical Importance: Majority of anemic samples were classified as NRA. Anemia was more severe in cats with RA. Erythrocyte indices were not sensitive indicators of RA.

25 July 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
EHEmma Hooijberg
Emma Hooijberg
MMMichele Miller
Michele Miller
CCCarolyn Cray
Carolyn Cray
PBPeter Buss
Peter Buss
GSGerhard Steenkamp
Gerhard Steenkamp
AGAmelia A. Goddard
Amelia A. Goddard
Investigation of globulin fractions by serum protein electrophoresis (SPE) is the first step towards evaluation of the proteome in the southern white rhinoceros (Ceratotherium simum simum). Furthermore, identification of changes in globulins in animals with poaching and other injuries can guide discovery of potentially useful biomarkers of inflammation. The aim of this study was to develop reference intervals for agarose gel SPE in healthy white rhinoceros and to compare these serum protein electrophoresis results to those from animals with tissue trauma. Reference intervals for total serum protein and agarose gel electrophoretic albumin and globulin fractions were generated using serum samples from 49 healthy free-ranging adult white rhinoceros. A standardised gating system together with identification of specific proteins by mass spectrometry aided in fraction identification. Six globulin fractions were identified: α1a, α1b, α2, β1, β2 and γ. Reference intervals were generated for total serum protein (76–111 g/L), albumin (10–27 g/L) and globulin fractions (α1a: 1.6–3.2 g/L; α1b: 1.7–3.6 g/L; α2: 16.1–26.6 g/L; β1: 6.6–18.2 g/L; β2: 11.8–30.4 g/L; γ: 10.4–23.1 g/L; albumin: globulin ratio: 0.12–0.39). Results were compared to those from 30 animals with various degrees and chronicities of tissue trauma. Wounded animals had lower concentrations of total serum protein, albumin, total globulin, α and β1 globulins, lower percentages of α2 and β1 globulins, and higher percentages of β2 and γ globulins. These protein changes are similar to those seen in human patients with wounds rather than classic acute phase or chronic inflammatory responses.