The efficiency, useful life and proper functioning of electrical devices directly depend on the quality of energy supplied. Moreover, the supply of energy within the adequate limits is necessary for the economic and social development in the regions served. Given these factors, in order to improve quality, ensure adequate voltage levels over the distribution networks, distribution companies invest in system improvements, voltage regulators, exchange of conductors and construction of new feeders and substations. In this paper the authors intend to present a methodology that uses the potential of the smart grids applied to the increase of the efficiency of the voltage control in the distribution systems. It is intended to reach a better quality of the rendered services and consequently the customers' larger satisfaction.
Maintenance techniques are fundamental in the context of the safe operation of continuous process installations, especially in electrical energy-transmission and/or -distribution substations. The operating conditions of power transformers are fundamental for the safe functioning of the electrical power system. Predictive maintenance consists of periodically monitoring the asset in use, in order to anticipate critical situations. This article proposes a methodology based on data science, machine learning and the Internet of Things (IoT), to track operational conditions over time and evaluate transformer aging. This characteristic is achieved with the development of a synchronization method for different databases and the construction of a model for estimating ambient temperatures using k-Nearest Neighbors. In this way, a history assessment is carried out with more consistency, given the environmental conditions faced by the equipment. The work evaluated data from three power transformers in different geographic locations, demonstrating the initial applicability of the method in identifying equipment aging. Transformer TR1 showed aging of , followed by TR2 with and TR3 showing in the evaluated period of time.
This study aims to analyze the transient stability of an unbalanced power distribution system (PDS) with distributed generation (DG), whose primary machine is a thermal turbine. This analysis is done by applying faults in different locations of the feeder and the determination of the critical clearing fault time. The evaluation is done with three load scenarios and for each of these thresholds were applied short circuit in four different system buses. Still, it was evaluated the dynamic response of the PDS and generator considering the following types of faults: three-phase, two phase-to-ground, phase-phase and phase-to-ground. The simulation results show interesting conclusions regarding the critical clearing fault time, showing a different behavior with respect to the case of generators connected to the transmission system.