Hanna Fotina

Prof. Dr. Hanna Fotina

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2022 in Toxins
Verified
Journal Article
Open access
PDF file
YWYanan Wang
Yanan Wang
XWXiaofei Wang
Xiaofei Wang
SWShuyun Wang
Shuyun Wang
HFHanna Fotina
Hanna Fotina
ZWZiliang Wang
Ziliang Wang
Simultaneous aflatoxin (AFB1) and zearalenone (ZEN) contamination in agro-products have become widespread globally and have a toxic superposition effect. In the present study, we describe a highly sensitive and specific dual lateral flow immunochromatographic assay (dual test strip) for rapid and simultaneous detection of AFB1 and ZEN in food and feed samples based on respective monoclonal antibodies (mAbs). Two immunogens AFB1-BSA (an AFB1 and bovine serum albumin (BSA) conjugate) and ZEN-BSA (a ZEN and BSA conjugate) were synthesized in oximation active ester (OAE) and amino glutaraldehyde (AGA). The molecular binding ratio of AFB1:BSA was 8.64:1, and that of ZEN:BSA was 17.2:1, identified by high-resolution mass spectrometry (HRMS) and an ultraviolet spectrometer (UV). The hybridoma cell lines 2A11, 2F6, and 3G2 for AFB1 and 2B6, 4D9 for ZEN were filtered by an indirect non-competitive enzyme-linked immunosorbent assay (inELISA) and an indirect competitive enzyme-linked immunosorbent assay (icELISA), respectively. As AFB1 mAb 2A11 and ZEN mAb 2B6 had the lowest 50% inhibitive concentration (IC50) and cross-reactivity (CR), they were selected for subsequent experiments. By systematically optimizing the preparation condition of gold nanoparticles (AuNPs), AuNPs-labeled mAbs, and detection condition, the visual limit of detection (LOD) of the dual test strip was 1.0 μg/L for AFB1 and 5.0 μg/L for ZEN, whereas that of the test strip reader was 0.23 μg/L for AFB1 and 1.53 μg/L for ZEN. The high reproducibility and stability of the dual test were verified using mycotoxin-spiked samples. The dual test strips were highly specific and sensitive for AFB1 and ZEN, which were validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Thus, the proposed AFB1 and ZEN dual test strip is suitable for rapid and simultaneous detection of AFB1 and ZEN contamination in food and feed samples.

10 June 2021 in Frontiers in Microbiology
Verified
Journal Article
Open access
XZXueqin Zhao
Xueqin Zhao
WLWang Lei
Wang Lei
CZChunling Zhu
Chunling Zhu
XXXiaojing Xia
Xiaojing Xia
SZShouping Zhang
Shouping Zhang
JHJianhe Hu
Jianhe Hu
Escherichia coli can cause intestinal diseases in humans and livestock, destroy the intestinal barrier, exacerbate systemic inflammation, and seriously threaten human health and animal husbandry development. The aim of this study was to investigate whether the antimicrobial peptide mastoparan X (MPX) was effective against E. coli infection. BALB/c mice infected with E. coli by intraperitoneal injection, which represents a sepsis model. In this study, MPX exhibited no toxicity in IPEC-J2 cells and notably suppressed the levels of interleukin-6 (IL-6), tumor necrosis factor-alpha (TNF-α), myeloperoxidase (MPO), and lactate dehydrogenase (LDH) released by E. coli. In addition, MPX improved the expression of ZO-1, occludin, and claudin and enhanced the wound healing of IPEC-J2 cells. The therapeutic effect of MPX was evaluated in a murine model, revealing that it protected mice from lethal E. coli infection. Furthermore, MPX increased the length of villi and reduced the infiltration of inflammatory cells into the jejunum. SEM and TEM analyses showed that MPX effectively ameliorated the jejunum damage caused by E. coli and increased the number and length of microvilli. In addition, MPX decreased the expression of IL-2, IL-6, TNF-α, p-p38, and p-p65 in the jejunum and colon. Moreover, MPX increased the expression of ZO-1, occludin, and MUC2 in the jejunum and colon, improved the function of the intestinal barrier, and promoted the absorption of nutrients. This study suggests that MPX is an effective therapeutic agent for E. coli infection and other intestinal diseases, laying the foundation for the development of new drugs for bacterial infections.

1 April 2020 in Veterinary Microbiology
Verified
Journal Article
Closed access
LWLei Wang
Lei Wang
XZXueqin Zhao
Xueqin Zhao
CZChunling Zhu
Chunling Zhu
YZYaya Zhao
Yaya Zhao
SLShuangshuang Liu
Shuangshuang Liu
JHJianhe Hu
Jianhe Hu

17 March 2022 in Toxins
Verified
Journal Article
Open access
PDF file
YWYanan Wang
Yanan Wang
XWXiaofei Wang
Xiaofei Wang
SWShuyun Wang
Shuyun Wang
HFHanna Fotina
Hanna Fotina
ZWZiliang Wang
Ziliang Wang
Zearalenone (ZEN) contamination in food and feed is prevalent and has severe effects on humans and animals post-consumption. Therefore, a sensitive, specific, rapid, and reliable method for detecting a single residue of ZEN is necessary. This study aimed to establish a highly sensitive and specific ZEN monoclonal antibody (mAb) and an indirect competitive enzyme-linked immunosorbent assay (icELISA) for the detection of ZEN residues in food and feed. The immunogen ZEN-BSA was synthesized via the amino glutaraldehyde (AGA) and amino diazotization (AD) methods and identified using 1H nuclear magnetic resonance (1H NMR), a high-resolution mass spectrometer (HRMS), and an ultraviolet spectrometer (UV). The coating antigens ZEN-OVA were synthesized via the oxime active ester (OAE), formaldehyde (FA), 1,4-butanediol diglycidyl ether (BDE), AGA, and AD methods. These methods were used to screen the best antibody/antigen combination of a heterologous icELISA. Balb/c mice were immunized with a low ZEN-BSA dose at long intervals and multiple sites. Suitable cell fusion mice and positive hybridoma cell lines were screened using a homologous indirect non-competitive ELISA (inELISA) and an icELISA. The ZEN mAbs were prepared by inducing ascites in vivo. The immunological characteristics of ZEN mAbs were then assessed. The standard curves of the icELISA for ZEN were constructed under optimal experimental conditions, and the performance of the icELISA was validated. The two ZEN-BSA immunogens (conjugation ratios, 11.6:1 (AGA) and 9.2:1 (AD)) were successfully synthesized. Four hybridoma cell lines (2B6, 4D9, 1A10, and 4G8) were filtered, of which 2B6 had the best sensitivity and specificity. The mAb 2B6-based icELISA was then developed. The limit of detection (LOD), the 50% inhibitive concentration (IC50), and the linear working range (IC20 to IC80) values of the icELISA were 0.76 μg/L, 8.69 μg/L, and 0.92–82.24 μg/L, respectively. The cross-reactivity (CR) of the icELISA with the other five analogs of ZEN was below 5%. Three samples were spiked with different concentrations of ZEN and detected using the icELISA. The average intra-assay recoveries, inter-assay recoveries, intra-assay coefficients of variations (CVs), and inter-assay CVs were 93.48–99.48%, 94.18–96.13%, 12.55–12.98%, and 12.53–13.58%, respectively. The icELISA was used to detect ZEN in various samples. The results were confirmed using high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) (correlation coefficient, 0.984). The proposed icELISA was highly sensitive, specific, rapid, and reliable for the detection of ZEN in food and feed samples.

9 September 2020 in Molecules
Verified
Journal Article
Open access
PDF file
YWYanan Wang
Yanan Wang
JJJinqing Jiang
Jinqing Jiang
HFHanna Fotina
Hanna Fotina
HZHaitang Zhang
Haitang Zhang
JCJunjie Chen
Junjie Chen
Aflatoxin (AF) contamination is a major concern in the food and feed industry because of its prevalence and toxicity. Improved aflatoxin detection methods are still needed. Immunoassays are an important method for total aflatoxin (TAF) analysis in food due to its technical advantages such as high specificity, sensitivity, and simplicity, but require high-quality antibodies. Here, we first review the three ways to prepare high-quality antibodies for TAF immunoassay, second, compare the advantages and disadvantages of antigen synthesis methods for B-group and G-group aflatoxins, and third, describe the status of novel genetic engineering antibodies. This review can provide new methods and ideas for the development of TAF immunoassays.

27 May 2021 in Toxins
Verified
Journal Article
Open access
PDF file
YWYanan Wang
Yanan Wang
XWXiaofei Wang
Xiaofei Wang
HZHaitang Zhang
Haitang Zhang
HFHanna Fotina
Hanna Fotina
JJJinqing Jiang
Jinqing Jiang
This study aimed to detect and monitor total Zearalenone (ZEN) and its five homologs (ZENs) in cereals and feed. The monoclonal antibodies (mAbs) with a high affinity and broad class specificity against ZENs were prepared, and the conditions of a heterologous indirect competitive ELISA (icELISA) were preliminarily optimized based on the ZEN mAbs. The immunogen ZEN-BSA was synthesized using the oxime active ester method (OAE) and identified using infrared (IR) and ultraviolet (UV). The coating antigen ZEN-OVA was obtained via the 1,4-butanediol diglycidyl ether method (BDE). Balb/c mice were immunized using a high ZEN-BSA dose with long intervals and at multiple sites. A heterologous indirect non-competitive ELISA (inELISA) and an icELISA were used to screen the suitable cell fusion mice and positive hybridoma cell lines. The ZEN mAbs were prepared by inducing ascites in vivo. The standard curve was established, and the sensitivity and specificity of the ZEN mAbs were determined under the optimized icELISA conditions. ZEN-BSA was successfully synthesized at a conjugation ratio of 17.2:1 (ZEN: BSA). Three hybridoma cell lines, 2D7, 3C2, and 4A10, were filtered, and their mAbs corresponded to an IgG1 isotype with a κ light chain. The mAbs titers were between (2.56 to 5.12) × 102 in supernatants and (1.28 to 5.12) × 105 in the ascites. Besides, the 50% inhibitive concentration (IC50) values were from 18.65 to 31.92 μg/L in the supernatants and 18.12 to 31.46 μg/L in the ascites. The affinity constant (Ka) of all of the mAbs was between 4.15 × 109 and 6.54 × 109 L/mol. The IC50 values of mAb 2D7 for ZEN, α-ZEL, β-ZEL, α-ZAL, β-ZAL and ZAN were 17.23, 16.71, 18.27, 16.39, 20.36 and 15.01 μg/L, and their cross-reactivities (CRs, %) were 100%, 103.11%, 94.31%, 105.13%, 84.63%, and 114.79%, respectively, under the optimized icELISA conditions. The limit of detection (LOD) for ZEN was 0.64 μg/L, and its linear working range was between 1.03 and 288.55 μg/L. The mAbs preparation and the optimization of icELISA conditions promote the potential development of a rapid test ELISA kit, providing an alternative method for detecting ZEN and its homologs in cereals and feed.