Helge Hecht

Mr. Helge Hecht

RECETOX
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 July 2024 in Environmental Science & Technology
Verified
Journal Article
Open access
YLYunjia Lai
Yunjia Lai
JKJeremy P. Koelmel
Jeremy P. Koelmel
DWDouglas I. Walker
Douglas I. Walker
EPElliott James Price
Elliott James Price
SPStefano Papazian
Stefano Papazian
GMGary W. Miller
Gary W. Miller
In the modern "omics" era, measurement of the human exposome is a critical missing link between genetic drivers and disease outcomes. High-resolution mass spectrometry (HRMS), routinely used in proteomics and metabolomics, has emerged as a leading technology to broadly profile chemical exposure agents and related biomolecules for accurate mass measurement, high sensitivity, rapid data acquisition, and increased resolution of chemical space. Non-targeted approaches are increasingly accessible, supporting a shift from conventional hypothesis-driven, quantitation-centric targeted analyses toward data-driven, hypothesis-generating chemical exposome-wide profiling. However, HRMS-based exposomics encounters unique challenges. New analytical and computational infrastructures are needed to expand the analysis coverage through streamlined, scalable, and harmonized workflows and data pipelines that permit longitudinal chemical exposome tracking, retrospective validation, and multi-omics integration for meaningful health-oriented inferences. In this article, we survey the literature on state-of-the-art HRMS-based technologies, review current analytical workflows and informatic pipelines, and provide an up-to-date reference on exposomic approaches for chemists, toxicologists, epidemiologists, care providers, and stakeholders in health sciences and medicine. We propose efforts to benchmark fit-for-purpose platforms for expanding coverage of chemical space, including gas/liquid chromatography-HRMS (GC-HRMS and LC-HRMS), and discuss opportunities, challenges, and strategies to advance the burgeoning field of the exposome.

17 March 2024 in Environment International
Verified
Journal Article
Open access
ŽTŽiga Tkalec
Žiga Tkalec
JAJean-Philippe Antignac
Jean-Philippe Antignac
NBNicole BAndow
Nicole BAndow
FBFrederic M. Béen
Frederic M. Béen
LBLidia Belova
Lidia Belova
EPElliott James Price
Elliott James Price
The chemical burden on the environment and human population is increasing. Consequently, regulatory risk assessment must keep pace to manage, reduce, and prevent adverse impacts on human and environmental health associated with hazardous chemicals. Surveillance of chemicals of known, emerging, or potential future concern, entering the environment-food-human continuum is needed to document the reality of risks posed by chemicals on ecosystem and human health from a one health perspective, feed into early warning systems and support public policies for exposure mitigation provisions and safe and sustainable by design strategies. The use of less-conventional sampling strategies and integration of full-scan, high-resolution mass spectrometry and effect-directed analysis in environmental and human monitoring programmes have the potential to enhance the screening and identification of a wider range of chemicals of known, emerging or potential future concern. Here, we outline the key needs and recommendations identified within the European Partnership for Assessment of Risks from Chemicals (PARC) project for leveraging these innovative methodologies to support the development of next-generation chemical risk assessment.

8 November 2024 in Analytical Chemistry
Verified
Journal Article
Open access
JKJoshua Klein
Joshua Klein
HLHenry Lam
Henry Lam
Tytus MakTytus Mak
Tytus Mak
WBWout Bittremieux
Wout Bittremieux
YPYasset Perez-Riverol
Yasset Perez-Riverol
EDEric W. Deutsch
Eric W. Deutsch
Mass spectral libraries are collections of reference spectra, usually associated with specific analytes from which the spectra were generated, that are used for further downstream analysis of new spectra. There are many different formats used for encoding spectral libraries, but none have undergone a standardization process to ensure broad applicability to many applications. As part of the Human Proteome Organization Proteomics Standards Initiative (PSI), we have developed a standardized format for encoding spectral libraries, called mzSpecLib (https://psidev.info/mzSpecLib). It is primarily a data model that flexibly encodes metadata about the library entries using the extensible PSI-MS controlled vocabulary and can be encoded in and converted between different serialization formats. We have also developed a standardized data model and serialization for fragment ion peak annotations, called mzPAF (https://psidev.info/mzPAF). It is defined as a separate standard, since it may be used for other applications besides spectral libraries. The mzSpecLib and mzPAF standards are compatible with existing PSI standards such as ProForma 2.0 and the Universal Spectrum Identifier. The mzSpecLib and mzPAF standards have been primarily defined for peptides in proteomics applications with basic small molecule support. They could be extended in the future to other fields that need to encode spectral libraries for nonpeptidic analytes.

7 August 2024 in Analytical Chemistry
Verified
Journal Article
Open access
Helge HechtHelge Hecht
Helge Hecht
WRWudmir Y. Rojas
Wudmir Y. Rojas
ZAZargham Ahmad
Zargham Ahmad
AKAleš Křenek
Aleš Křenek
JKJana Klánová
Jana Klánová
EPElliott James Price
Elliott James Price
There is a lack of experimental electron ionization high-resolution mass spectra available to assist compound identification. The in silico generation of mass spectra by quantum chemistry can aid annotation workflows, in particular to support the identification of compounds that lack experimental reference spectra, such as environmental chemicals. We present an open-source, semiautomated workflow for the in silico prediction of electron ionization high-resolution mass spectra at 70 eV based on the QCxMS software. The workflow was applied to predict the spectra of 367 environmental chemicals, and the accuracy was evaluated by comparison to experimental reference spectra acquired. The molecular flexibility, number of rotatable bonds, and number of electronegative atoms of a compound were negatively correlated with prediction accuracy. Few analytes are predicted to sufficient accuracy for the direct application of predicted spectra in spectral matching workflows (overall average score 428). The m/z values of the top 5 most abundant ions of predicted spectra rarely match ions in experimental spectra, evidencing the disconnect between simulated fragmentation pathways and empirical reaction mechanisms.

15 September 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Helge HechtHelge Hecht
Helge Hecht
MSMhd Hasan Sarhan
Mhd Hasan Sarhan
Vlad PopoviciVlad Popovici
Vlad Popovici
A novel deep autoencoder architecture is proposed for the analysis of histopathology images. Its purpose is to produce a disentangled latent representation in which the structure and colour information are confined to different subspaces so that stain-independent models may be learned. For this, we introduce two constraints on the representation which are implemented as a classifier and an adversarial discriminator. We show how they can be used for learning a latent representation across haematoxylin-eosin and a number of immune stains. Finally, we demonstrate the utility of the proposed representation in the context of matching image patches for registration applications and for learning a bag of visual words for whole slide image summarization.

2 November 2022 in Journal of Open Source Software
Verified
Journal Article
Open access
PDF file
MTMatej Troják
Matej Troják
Helge HechtHelge Hecht
Helge Hecht
MČMartin Čech
Martin Čech
EPElliott James Price
Elliott James Price