Jeong-Woo Choi

Prof. Dr. Jeong-Woo Choi

Department of Chemical and Biomolecular Engineering, Graduate School of Management of Technology, Sogang University, 35 Baekbeom-Ro, Mapo-Gu, Seoul Korea

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2020 in Nano Letters
Verified
Journal Article
Closed access
JCJin-Ha Choi
Jin-Ha Choi
JLJoungpyo Lim
Joungpyo Lim
MSMinkyu Shin
Minkyu Shin
SPSe-Hwan Paek
Se-Hwan Paek
Jeong-Woo ChoiJeong-Woo Choi
Jeong-Woo Choi

Verified
Journal Article
Open access
PDF file
Jin-Ho LeeJin-Ho Lee
Jin-Ho Lee
HCHyeon-Yeol Cho
Hyeon-Yeol Cho
HCHye Kyu Choi
Hye Kyu Choi
JLJi-Young Lee
Ji-Young Lee
Jeong-Woo ChoiJeong-Woo Choi
Jeong-Woo Choi
Gold nanoparticles (GNPs) have been widely utilized to develop various biosensors for molecular diagnosis, as they can be easily functionalized and exhibit unique optical properties explained by plasmonic effects. These unique optical properties of GNPs allow the expression of an intense color under light that can be tuned by altering their size, shape, composition, and coupling with other plasmonic nanoparticles. Additionally, they can also enhance other optical signals, such as fluorescence and Raman scattering, making them suitable for biosensor development. In this review, we provide a detailed discussion of the currently developed biosensors based on the aforementioned unique optical features of GNPs. Mainly, we focus on four different plasmonic biosensing methods, including localized surface plasmon resonance (LSPR), surface-enhanced Raman spectroscopy (SERS), fluorescence enhancement, and quenching caused by plasmon and colorimetry changes based on the coupling of GNPs. We believe that the topics discussed here are useful and able to provide a guideline in the development of novel GNP-based biosensors in the future.

1 January 2015 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
HJHee Dong Jang
Hee Dong Jang
SKSun Kyung Kim
Sun Kyung Kim
HCHankwon Chang
Hankwon Chang
Jeong-Woo ChoiJeong-Woo Choi
Jeong-Woo Choi

9 August 2021 in ACS Nano
Verified
Journal Article
Closed access
JCJin-Ha Choi
Jin-Ha Choi
MSMinkyu Shin
Minkyu Shin
Letao YangLetao Yang
Letao Yang
BCBrian Conley
Brian Conley
JYJinho Yoon
Jinho Yoon
Jeong-Woo ChoiJeong-Woo Choi
Jeong-Woo Choi

3 January 2019 in Nano Convergence
Verified
Journal Article
Open access
PDF file
JJJinhee Jo
Jinhee Jo
JYJinho Yoon
Jinho Yoon
Taek LeeTaek Lee
Taek Lee
HCHyeon-Yeol Cho
Hyeon-Yeol Cho
JLJi-Young Lee
Ji-Young Lee
Jeong-Woo ChoiJeong-Woo Choi
Jeong-Woo Choi
In this research, we developed electrochemical biosensor which was composed of hemoglobin (Hb)-DNA conjugate on nanoporous gold thin film (NPGF) for hydrogen peroxide (H2O2) detection. For the first time, Hb and DNA was conjugated as a sensing platform for uniform orientation of Hb on electrode. The newly developed Hb-DNA conjugate was designed to prevent Hb from aggregation on electrode. DNA hybridization of Hb-DNA conjugate and complementary DNA (cDNA) on NPGF electrode induced uniformly assembled biosensor. Furthermore, NPGF electrode fabrication method was introduced to the increment of the surface area. To confirm the conjugation of Hb-DNA conjugate, sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) and ultraviolet–visible spectroscopy (UV–VIS) were used. Formation of the NPGF electrode was verified by scanning electron microscope (SEM). Atomic force microscopy (AFM) was operated for the confirmation of Hb-DNA immobilization on electrode. The electrochemical property of fabricated electrode was investigated by cyclic voltammetry (CV). Also, H2O2 sensing performance of fabricated electrode was investigated by amperometric i-t curve technique. This sensor showed a wide linear range from 0.00025 to 5.00 mM and a correlation coefficient of R2 = 0.9986. The detection limit was 250 nM. Proposed biosensor can be utilized as a sensing platform for development of biosensor.

20 February 2019 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Jin-Ho LeeJin-Ho Lee
Jin-Ho Lee
SPSoo-Jeong Park
Soo-Jeong Park
Jeong-Woo ChoiJeong-Woo Choi
Jeong-Woo Choi
Graphene, a single atom thick layer of two-dimensional closely packed honeycomb carbon lattice, and its derivatives have attracted much attention in the field of biomedical, due to its unique physicochemical properties. The valuable physicochemical properties, such as high surface area, excellent electrical conductivity, remarkable biocompatibility and ease of surface functionalization have shown great potentials in the applications of graphene-based bioelectronics devices, including electrochemical biosensors for biomarker analysis. In this review, we will provide a selective overview of recent advances on synthesis methods of graphene and its derivatives, as well as its application to electrochemical biosensor development. We believe the topics discussed here are useful, and able to provide a guideline in the development of novel graphene and on graphene-like 2-dimensional (2D) materials based biosensors in the future.