Masoud Nekooei

Dr. Masoud Nekooei


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2019 in KSCE Journal of Civil Engineering
Verified
Journal Article
Open access
PDF file
MFMohammad Amin Fadaie
Mohammad Amin Fadaie
MNMasoud Nekooei
Masoud Nekooei
PJPasha Javadi
Pasha Javadi
Dams are rarely built on non-permeable lands, therefore usually reservoir leakage from dam foundations cause major problems for large dams which affect dams performances. One method of controlling the origin of leaks is to use plastic concrete cutoff walls. Bentonite is one of the most important materials used in constructing plastic concrete which act as a stabilizing agent. It is from clay materials having high water absorption and swelling of 300% properties even after contacting with water. These properties may cause negative effects on plastic concretes that include deep cracks and high reductions on its strength. In order to eliminate these effects, plastic concretes must be mixed with water at least 24 hours before usage and then they must be blended by special blades until they are totally saturated. This process costs huge time and money. Therefore, in this research, dry bentonite has been added to the mixer with particular method. It can be seen saving time and money and the properties of plastic concrete such as compressive strength, tensile strength, slump and permeability will not be slightly changed.

5 April 2022 in Ocean Engineering
Verified
Journal Article
Closed access
MAMehdi Alavinezhad
Mehdi Alavinezhad
MHMadjid Ghodsi Hassanabad
Madjid Ghodsi Hassanabad
MKMohammad Javad Ketabdari
Mohammad Javad Ketabdari
MNMasoud Nekooei
Masoud Nekooei

7 September 2020 in Journal of Vibration and Control
Verified
Journal Article
Closed access
PDF file
HBHossein Babajanian Bisheh
Hossein Babajanian Bisheh
GAGholamreza Ghodrati Amiri
Gholamreza Ghodrati Amiri
MNMasoud Nekooei
Masoud Nekooei
EDEhsan Darvishan
Ehsan Darvishan
In this article, a novel vibration-based damage detection approach is proposed based on selecting effective cepstral coefficients, consisting of three main stages: (1) signal processing and feature extraction, (2) damage detection by combining effective cepstral coefficients through feature selection methods, and (3) performance evaluation. First, two feature extraction techniques are used in damage identification systems, including linear prediction cepstral coefficients and mel frequency cepstral coefficients. Second, to improve the performance of damage detection, the combination of the effective cepstral coefficients is proposed as a damage index. By applying several feature selection methods, the most effective coefficients are found and then combined to create a subset that carries the most significant information about the structural damage. Finally, the support vector machine classifier is performed to evaluate the proposed approach in detecting the structural damage. The proposed technique is verified using a suite of numerical and full-scale studies. Results confirm that the proposed method achieves a significant performance with great accuracy and reduces false alarms.

1 August 2021 in Proceedings of the Institution of Civil Engineers - Structures and Buildings
Verified
Journal Article
Closed access
MNMasoud Nekooei
Masoud Nekooei
Navid RahgozarNavid Rahgozar
Navid Rahgozar
NRNima Rahgozar
Nima Rahgozar
Mass isolation of structures is an efficient vibration-control technique for reducing earthquake effects on buildings. This paper introduces a vertical seismic isolated rocking-core system (VSI-RCS) in which a controlled rocking-core is separated from the frame by viscous fuses. The controlled rocking-core provides the self-centring capability while the viscous dampers limit the lateral displacement and dissipate the majority of the seismic energy. An analytical solution is proposed for estimation of the optimal damping constant of the dampers along with the corresponding fundamental frequencies and damping ratio of the VSI-RCS. A parametric study was carried out to quantify non-classical dynamic characteristics and spectral analysis was performed to examine the seismic performance of the VSI-RCS compared with rocking-core systems. The proposed formulas were found to be applicable for rapid eigen-analysis and, compared with non-isolated rocking-core systems, proper seismic efficiency of the VSI-RCS was observed.

1 January 2019 in Latin American Journal of Solids and Structures
Verified
Journal Article
Open access
PDF file
SFSahand Sarioletlagh Fard
Sahand Sarioletlagh Fard
MNMasoud Nekooei
Masoud Nekooei
AOAsghar Vatani Oskouei
Asghar Vatani Oskouei
AAArmin Aziminejad
Armin Aziminejad
The behavior and response of pipelines subjected to slip fault movement is studied by numerical simulations as well as experimental setup. A finite element modeling is also developed via ABAQUS software. In this study, an artificial accelerogram is applied to the system and matched against the response spectrum according to the standard No. 2800 (Iranian code of practice for seismic resistant design of buildings, 2014). Three different pipe nominal sizes and thicknesses (1 ½”, 2” and 4”) are considered in the experiments on the shaking table. According to the results, plastic hinge as well as the extremum stress and strain is formed in the fixed soil wedge and at locations close to the fault line. Further, as the pipe D/t ratio increases, the plastic hinge forms further away from the fault line. According to the results, the pipe-soil strain ratio (εp/s) has lower values at larger pipe diameters. Also, the axial strains would be greater for the systems with higher (εp/s) ratios.

30 January 2017 in Civil Engineering Journal
Verified
Journal Article
Open access
PDF file
RJReza Jamalpour
Reza Jamalpour
MNMasoud Nekooei
Masoud Nekooei
AMAbdolreza Sarvghad Moghadam
Abdolreza Sarvghad Moghadam
Connections in MRFs are the most important members and seismic behaviour is affected by function of beam column connections as well as column foundation connections. If the connections are able to provide the required ductility and efficiency against the seismic excitation, the seismic capacity of the MRF performed by these connections will be affected. SMAs have recently been used as a tool to dissipate energy in structures. So far, using of them for column foundation connections has been applied much less. In this paper, SMAs have been introduced and an innovated column foundation connection equipped with SMA has been suggested. Micro and macro behaviour of the connection has been studied and it was applied in sample MRF. Seismic response of the MRF under different earthquakes by equipping the connection with steels/SMAs bars have been studied and compared. Finally, results indicated that MRF with this connection showed proper seismic performance.