Matthias Kreuzer

Dr. Matthias Kreuzer

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in Journal of Clinical Anesthesia
Verified
Journal Article
Closed access
DODavid P. Obert
David P. Obert
CSCatrin Schweizer
Catrin Schweizer
SZSebastian Zinn
Sebastian Zinn
SKStephan Kratzer
Stephan Kratzer
DHDarren Hight
Darren Hight
MKMatthias Kreuzer
Matthias Kreuzer

29 August 2022 in Journal of Clinical Anesthesia
Verified
Journal Article
Closed access
RLRieke Lutz
Rieke Lutz
CMClaudia Müller
Claudia Müller
SDSrdjan Dragovic
Srdjan Dragovic
FSFrederick Schneider
Frederick Schneider
KRKatharina Ribbe
Katharina Ribbe
SKStephan Kratzer
Stephan Kratzer

19 August 2020 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Open access
PDF file
FDFalk von Dincklage
Falk von Dincklage
CJCarlo Jurth
Carlo Jurth
GSGerhard Schneider
Gerhard Schneider
PGPaul S García
Paul S García
MKMatthias Kreuzer
Matthias Kreuzer
Electroencephalographic (EEG) patient monitoring during general anesthesia can help to assess the real-time neurophysiology of unconscious states. Some monitoring systems like the SEDLine Root allow export of the EEG to be used for retrospective analysis. We show that changes made to the SEDLine display during recording affected the recorded EEG. These changes can strongly impact retrospective analysis of EEG signals. Real-time changes of the feed speed in the SEDLine Root device display modifies the sampling rate of the exported EEG. We used a patient as well as a simulated EEG recording to highlight the effects of the display settings on the extracted EEG. Therefore, we changed EEG feed and amplitude resolution on the display in a systematic manner. To visualize the effects of these changes, we present raw EEG segments and the density spectral array of the recording. Changing the display’s amplitude resolution affects the amplitudes. If the amplitude resolution is too fine, the exported EEG contains clipped amplitudes. If the resolution is too coarse, the EEG resolution becomes too low leading to a low-quality signal making frequency analysis impossible. The proportion of clipped or zero-line data caused by the amplitude setting was > 60% in our sedated patient. Changing the display settings results in undocumented changes in EEG amplitude, sampling rate, and signal quality. The occult nature of these changes could make the analysis of data sets difficult if not invalid. We strongly suggest researchers adequately define and keep the EEG display settings to export good quality EEG and to ensure comparability among patients.

21 September 2018 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
PDF file
AFAntonia Fleischmann
Antonia Fleischmann
SPStefanie Pilge
Stefanie Pilge
TKTobias Kiel
Tobias Kiel
SKStephan Kratzer
Stephan Kratzer
GSGerhard Schneider
Gerhard Schneider
MKMatthias Kreuzer
Matthias Kreuzer
Different anesthetic agents induce burst suppression in the electroencephalogram (EEG) at very deep levels of general anesthesia. EEG burst suppression has been identified to be a risk factor for postoperative delirium (POD). EEG based automated detection algorithms are used to detect burst suppression patterns during general anesthesia and a burst suppression ratio (BSR) is calculated. Unfortunately, applied algorithms do not give information as precisely as suggested, often resulting in an underestimation of the patients’ burst suppression level. Additional knowledge of substance-specific burst suppression patterns could be of great importance to improve the ability of EEG based monitors to detect burst suppression. In a re-analysis of EEG recordings obtained from a previous study, we analyzed EEG data of 45 patients undergoing elective surgery under general anesthesia. The patients were anesthetized with sevoflurane, isoflurane or propofol (n = 15, for each group). After skin incision, the used agent was titrated to a level when burst suppression occurred. In a visual analysis of the EEG, blinded to the used anesthetic agent, we included the first distinct burst in our analysis. To avoid bias through changing EEG dynamics throughout the burst, we only focused on the first 2 s of the burst. These episodes were analyzed using the power spectral density (PSD) and normalized PSD, the absolute burst amplitude and absolute burst slope, as well as permutation entropy (PeEn). Our results show significant substance-specific differences in the architecture of the burst. Volatile-induced bursts showed higher burst amplitudes and higher burst power. Propofol-induced bursts had significantly higher relative power in the EEG alpha-range. Further, isoflurane-induced bursts had the steepest burst slopes. We can present the first systematic comparison of substance-specific burst characteristics during anesthesia. Previous observations, mostly derived from animal studies, pointing out the substance-specific differences in bursting behavior, concur with our findings. Our findings of substance-specific EEG characteristics can provide information to help improve automated burst suppression detection in monitoring devices. More specific detection of burst suppression may be helpful to reduce excessive EEG effects of anesthesia and therefore the incidence of adverse outcomes such as POD.

22 February 2019 in Trials
Verified
Journal Article
Open access
PDF file
AGAmy Gaskell
Amy Gaskell
RPRebecca Pullon
Rebecca Pullon
DHDarren Hight
Darren Hight
JTJonathan Termaat
Jonathan Termaat
GMGay Mans
Gay Mans
JSJamie Sleigh
Jamie Sleigh
Postoperative delirium may manifest in the immediate post-anaesthesia care period. Such episodes appear to be predictive of further episodes of inpatient delirium and associated adverse outcomes. Frontal electroencephalogram (EEG) findings of suppression patterns and low proprietary index values have been associated with postoperative delirium and poor outcomes. However, the efficacy of titrating anaesthesia to proprietary index targets for preventing delirium remains contentious. We aim to assess the efficacy of two strategies which we hypothesise could prevent post-anaesthesia care unit (PACU) delirium by maximising the alpha oscillation observed in frontal EEG channels during the maintenance and emergence phases of anaesthesia. This is a 2 × 2 factorial, double-blind, stratified, randomised control trial of 600 patients. Eligible patients are those aged 60 years or over who are undergoing non-cardiac, non-intracranial, volatile-based anaesthesia of expected duration of more than 2 h. Patients will be stratified by pre-operative cognitive status, surgery type and site. For the maintenance phase of anaesthesia, patients will be randomised (1:1) to an alpha power-maximisation anaesthesia titration strategy versus standard care avoiding suppression patterns in the EEG. For the emergence phase of anaesthesia, patients will be randomised (1:1) to early cessation of volatile anaesthesia and emergence from an intravenous infusion of propofol versus standard emergence from volatile anaesthesia only. The primary study outcomes are the power of the frontal alpha oscillation during the maintenance and emergence phases of anaesthesia. Our main clinical outcome of interest is PACU delirium. This is a largely exploratory study; the extent to which EEG signatures can be modified by titration of pharmacological agents is not known. The underlying concept is maximisation of anaesthetic efficacy by individualised drug titration to a clearly defined EEG feature. The interventions are already clinically used strategies in anaesthetic practice, but have not been formally evaluated. The addition of propofol during the emergence phase of volatile-based general anaesthesia is known to reduce emergence delirium in children; however, the efficacy of this strategy in older patients is not known. Australian and New Zealand Clinical Trial Registry, ID: 12617001354370 . Registered on 27/09/2017.

20 December 2024 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Closed access
PDF file
NMNitin Manohara
Nitin Manohara
AFAlessandra Ferrari
Alessandra Ferrari
AGAdam Greenblatt
Adam Greenblatt
ABAndrea Berardino
Andrea Berardino
CPCristina Peixoto
Cristina Peixoto
FLFrancisco A. Lobo
Francisco A. Lobo