Dumitru Toader

Prof. Dr. Dumitru Toader

Politehnica University of Timisoara
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
DTDumitru Toader
Dumitru Toader
MGMarian Greconici
Marian Greconici
DVDaniela Vesa
Daniela Vesa
MVMaria Vintan
Maria Vintan
CȘClaudiu Șolea
Claudiu Șolea
Settings of protection are essential to ensure the sensitivity and selectivity needed to detect defects. Making the correct settings requires the calculation of the fault currents with as little error as possible. Fault currents are influenced by the parameters of the electrical networks, including the state of the insulation and the Petersen coil, which changes during their operation electrical networks. This paper analyzes how the insulation parameters of medium voltage power lines, the parameters of the Petersen coil used to treat the neutral of the medium voltage electrical network and the value of the resistance at the fault location influence the fault current in the case of a single-phase fault. The large number of single-phase faults that occur in medium voltage electrical networks justifies this analysis. The symmetrical components method was used to calculate the fault current. The results obtained by calculation were verified experimentally by causing a single-phase-to-ground fault in a real medium voltage network. The paper presents the situations in which the analytical calculation of the single-phase-to-ground fault current can lead to inadmissibly large errors, even over 50%, but also the situations in which the errors fall below 3%.

3 November 2015
Verified
Book Chapter
Closed access
PDF file
DTDumitru Toader
Dumitru Toader
CBCostantin Blaj
Costantin Blaj
PRPetru Ruset
Petru Ruset
IHIoan Dorin Hategan
Ioan Dorin Hategan
NPNicolae Pinte
Nicolae Pinte
BABeatrice Arvinti
Beatrice Arvinti

7 July 2023 in Mathematics
Verified
Journal Article
Open access
PDF file
DTDumitru Toader
Dumitru Toader
MVMaria Vintan
Maria Vintan
The electrical energy supply of industrial equipment is provided by electrical power stations with high- (HT), medium- (MV) and low-voltage (LV) busbars. Consumers are connected to either MV or LV busbars. In this paper, a real power station was considered, through which the gasoline extraction from the well gas installation is powered. Electric consumers (electric motors) supplied by a MV busbar have active power of 13.54 MW, and those fed by a LV busbar have active power of 6.4 MW. Since electrical consumers operate in explosive environments, the design and operating conditions are more severe than in the case of electrical installations operating in non-explosive environments. The case of a single phase-to-ground fault occurring on the HV transmission lines feeding the power station has been analysed. First, the mathematical models for the calculation of the phase voltages, the dissymmetry and asymmetry coefficients, the reduction coefficient of the plus sequence component, and the effective values of the phase voltages were established. The influence of the source impedance (the equivalent impedance of the HV transmission lines) and of the neutral point configuration of the HV/MV medium-voltage transformer on the calculated quantities was analysed. Then, the results obtained using the established mathematical models were compared with those obtained experimentally by provoking a single-phase-to-ground fault near the HV busbars of the real power station. This study has shown that the de-symmetrisation of the phase voltages of the MV and LV busbars is lower when using the Y/Δ connection for the HV/MV transformer. As a result, it is recommended the Y/Δ connection be used for this transformer, instead of the Y0/Δ connection.

1 January 2007
Verified
Conference Paper
Closed access
DTDumitru Toader
Dumitru Toader
CBConstantin Blaj
Constantin Blaj
SHStefan Haragus
Stefan Haragus
The touch voltage and the step voltage in the case of a broken conductor from a medium voltage network is analyzed in this paper. The distribution of the electric field in the area of the broken and grounded conductor is studied using a FEM program.

7 August 2021 in Designs
Verified
Journal Article
Open access
PDF file
DTDumitru Toader
Dumitru Toader
MGMarian Greconici
Marian Greconici
DVDaniela Vesa
Daniela Vesa
MVMaria Vintan
Maria Vintan
CȘClaudiu Șolea
Claudiu Șolea
ITIldiko Tatai
Ildiko Tatai
One important problem in the operation of medium voltage networks is the detection of a single-line-to-ground fault in its incipient state, when the fault resistance values are very high. In a medium voltage (MV) distribution network with a neutral grounding resistor (NGR), one of the methods employed to discriminate a single line-to-ground fault is the use of an overcurrent relay with an operating characteristic adjusted according to the effective value of the current flowing through the limiting resistor. In case of a single line-to-ground fault with a high fault resistance value, the correct tripping settings of the protective relay require the precise computation of this current. In comparison to the assumptions made by the models from the literature—the three-phase voltage system of the medium voltage busbars is symmetrical and there are no active power losses in the network insulation—the model proposed in this paper considers the pre-fault zero-sequence voltage of the medium voltage busbars and the active power losses in the network insulation, which is necessary in certain fault conditions where the use of the former leads to unacceptable errors.

26 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
DTDumitru Toader
Dumitru Toader
MVMaria Vintan
Maria Vintan
CȘClaudiu Șolea
Claudiu Șolea
DVDaniela Vesa
Daniela Vesa
MGMarian Greconici
Marian Greconici
The paper analyses how the characteristics of the medium-voltage network with insulated neutral and the conditions under which the single line-to-ground fault occurs (insulation condition and value of the fault resistance) influence the zero-sequence components of the voltage of the transformer station medium-voltage bus bar, the fault current, the currents of the faulted line and the currents of the other non-faulted power lines connected to the transformer station bus bars. Assuming the waveform of the medium voltage bus voltages in the transformer station is known, the influence of the fault resistance on the total distortion coefficient of the fault current is analysed. This establishes the conditions under which a single line-to-ground fault can be detected by controlling the total distortion coefficient of the fault current and the currents of the fault-free lines. It also examines the conditions under which a single line-to-ground fault can be selectively detected by checking the effective value and direction of flow of the zero-sequence currents of the medium-voltage lines during the fault. The results obtained by the calculation were verified experimentally in the medium voltage network considered in the study. The acceptable differences, considering the degree of accuracy with which the parameters of a medium voltage network are known, between the results obtained by calculation and those obtained experimentally show that the simplifying assumptions accepted for the mathematical models used in the calculation are correct.