Objective: A simple, rapid, economical, and highly sensitive stability-indicating HPLC method was developed and fully validated for determination of enalapril maleate in presence of its related substances namely enalaprilat dihydrate and diketopiperazine.Methods: Chromatographic separation was achieved on Grace Platinumр C8 EPS column (4.6 mm i.d. X 250 mm, 5 μm) at room temperature. The mobile phase consisted of acetonitrile: 20 mmol phosphate buffer adjusted to pH 2.2 (25:75 v/v) isocratically pumped at a flow rate 2 ml/min and UV-detection was monitored at 215 nm.Results: The proposed method was validated according to ICH guidelines with total run time less than 9 min. The correlation coefficient (r2) was noted as 0.99981 which states that the method was good linear to the concentration versus peak area responses. The developed method found to be high sensitivity with LOD and LOQ of 0.021 and 0.062 %; respectively. The developed, validated method was successfully applied for the determination of enalapril maleate in presence of their impurities in tablet dosage form.Conclusion: A rapid, economical, simple and sensitive HPLC method was developed and validated for the determination of enalapril maleate in tablet dosage form in presence of their impurities. The developed method can help research studies, quality control and routine analysis with lesser resources available. Therefore, the proposed validated method is fast and reliable and can be used for routine quantitative analysis as well as quality control of enalapril maleate in pharmaceutical formulation.
This review draws attention to the use of chiral monolithic silica HPLC columns for the enantiomeric separation and determination of chiral compounds. Properties and advantages of monolithic silica HPLC columns are also highlighted in comparison to conventional particle-packed, fused-core, and sub-2-µm HPLC columns. Nano-LC capillary monolithic silica columns as well as polymeric-based and hybrid-based monolithic columns are also demonstrated to show good enantioresolution abilities. Methods for introducing the chiral selector into the monolithic silica column in the form of mobile phase additive, by encapsulation and surface coating, or by covalent functionalization are described. The application of molecular modeling methods to elucidate the selector–selectand interaction is discussed. An application for enantiomeric impurity determination is also considered.
8 November 2017 in International Journal of Applied Pharmaceutics
Objective: A rapid, simple and sensitive RP-HPLC method was developed and validated for the determination of bisoprolol fumarate in bulk and pharmaceutical dosage form. Methods: Chromatographic separation was achieved within 2.5 min on ACQUITY Arc System, Waters Symmetry C18 column (3.9 mm i.d. X 150 mm, 5 μm particle sizes) using a mobile phase consisted of acetonitrile: phosphate buffer (25:75 v/v) in an isocratic mode at a flow rate of 1.4 ml/min. The pH of the mobile phase was adjusted to 7.0 with orthophosphoric acid and UV detection was set at 226 nm. Results: The retention time for bisoprolol fumarate was found to be 2.09 min. The proposed method was validated according to ICH guidelines with respect to linearity, specificity precision, accuracy and robustness. The limit of detection and limit of quantification are calculated and found to be 0.4825 and 1.4621 μg/ml; respectively. Conclusion:The proposed method can help research studies, quality control and routine analysis with lesser resources available. The results of the assay of pharmaceutical formulation of the developed method are highly reliable and reproducible and is in good agreement with the label claim of the medicines. Keywords: Bisoprolol, High-Performance Liquid Chromatography, Validation, ICH guidelines
Our main target and concept was to develop a method for the determination of the most prescribed antilipemic drug, atorvastatin, together with its related substances, with a single sample preparation and during a single chromatographic run, in the shortest possible period of time, with the lowest possible mobile phase consumption. A new rapid, simple chromatographic method for the determination of atorvastatin and its main specified impurities was developed, using different chromatographic columns. With this new concept of a mobile phase and a powerful core–shell, or a superficially porous silica-based column, satisfactory results for targeted parameters, such as critical peak resolution, run time length, and column backpressure, were achieved. The analysis is performed within a run duration of less than 15 min, which is about six times shorter than the official European Pharmacopoeia method. The chromatogram performances suggests that the method limit of quantification (LOQ) can be about 7 times lower, and the limit of detection (LOD) about 20 times lower, using an injection volume of only 2 µl. This was confirmed by the performed method validation in accordance with the International Conference on Harmonization (ICH) guideline for the validation of analytical procedures Q2(R1), where the selectivity, linearity, accuracy, precision, limit of quantification, and limit of detection were tested and confirmed.