We design and develop a low-cost pyroelectric detector-based IR motion-tracking system. We study the characteristics of the detector and the Fresnel lenses that are used to modulate the visibility of the detectors. We build sensor clusters in different configurations and demonstrate their use for human motion tracking.
The Clouds and the Earth’s Radiant Energy System (CERES) project provides observations of Earth’s radiation budget using measurements from CERES instruments onboard the Terra, Aqua and Suomi National Polar-orbiting Partnership (S-NPP) satellites. As the objective is to create a long-term climate data record, it is necessary to periodically reprocess the data in order to incorporate the latest calibration changes and algorithm improvements. Here, we focus on the improvements and validation of CERES Terra and Aqua radiances in Edition 4, which are used to generate higher-level climate data products. Onboard sources indicate that the total (TOT) channel response to longwave (LW) radiation has increased relative to the start of the missions by 0.4% to 1%. In the shortwave (SW), the sensor response change ranges from −0.4% to 0.6%. To account for in-orbit changes in SW spectral response function (SRF), direct nadir radiance comparisons between instrument pairs on the same satellite are made and an improved wavelength dependent degradation model is used to adjust the SRF of the instrument operating in a rotating azimuth plane scan mode. After applying SRF corrections independently to CERES Terra and Aqua, monthly variations amongst these instruments are highly correlated and the standard deviation in the difference of monthly anomalies is 0.2 Wm−2 for ocean and 0.3 Wm−2 for land/desert. Additionally, trends in CERES Terra and Aqua monthly anomalies are consistent to 0.21 Wm−2 per decade for ocean and 0.31 Wm−2 per decade for land/desert. In the LW, adjustments to the TOT channel SRF are made to ensure that removal of the contribution from the SW portion of the TOT channel with SW channel radiance measurements during daytime is consistent throughout the mission. Accordingly, anomalies in day–night LW difference in Edition 4 are more consistent compared to Edition 3, particularly for the Aqua land/desert case.
The size of infrared camera systems can be reduced by collecting low-resolution images in parallel with multiple narrow-aperture lenses rather than collecting a single high-resolution image with one wide-aperture lens. We describe an infrared imaging system that uses a three-by-three lenslet array with an optical system length of 2.3 mm and achieves Rayleigh criteria resolution comparable with a conventional single-lens system with an optical system length of 26 mm. The high-resolution final image generated by this system is reconstructed from the low-resolution images gathered by each lenslet. This is accomplished using superresolution reconstruction algorithms based on linear and nonlinear interpolation algorithms. Two implementations of the ultrathin camera are demonstrated and their performances are compared with that of a conventional infrared camera.
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
6 November 2023 in IEEE Transactions on Geoscience and Remote Sensing
Six Clouds and the Earth’s Radiant Energy System (CERES) instruments on four satellites are used to produce a global continuous multi-decadal record of Earth’s radiation budget (ERB) at the top-of-atmosphere (TOA). Each CERES instrument was calibrated and characterized on the ground before launch, while post-launch calibration is conducted using on-board calibration sources. The performance of the CERES instruments is verified using vicarious approaches involving both Earth and celestial targets. In this paper, we describe the calibration and validation approach and demonstrate the performance of the CERES instruments on the Terra and Aqua spacecrafts over the twenty-year period since launch. Validation results demonstrate that after applying the appropriate calibration corrections, all four instruments are stable and perform consistently with each other. Comparisons of observations between instruments on the two spacecrafts during orbital crossings further confirm the consistent performance across all instruments over the twenty-year period.
The Clouds and the Earth’s Radiant Energy System (CERES) instruments have enabled the generation of a multi-decadal Earth radiation budget (ERB) climate data record (CDR) at the top of the Earth’s atmosphere, within the atmosphere, and at the Earth’s surface. Six CERES instruments have been launched over the course of twenty years, starting in 1999. To seamlessly continue the data record into the future, there is a need to radiometrically scale observations from newly launched instruments to observations from the existing data record. In this work, we describe a methodology to place the CERES Flight Model (FM) 5 instrument on the Suomi National Polar-orbiting Partnership (SNPP) spacecraft on the same radiometric scale as the FM3 instrument on the Aqua spacecraft. We determine the required magnitude of radiometric scaling by using spatially and temporally matched observations from these two instruments and describe the process to radiometrically scale SNPP/FM5 to Aqua/FM3 through the instrument spectral response functions. We also present validation results after application of this radiometric scaling and demonstrate the long-term consistency of the SNPP/FM5 record in comparison with the CERES instruments on Aqua and Terra.