Bo Li

Dr. Bo Li

146 School of Applied and Engineering Physics, Cornell University, Ithaca, NY 14850, USA

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2019 in Nature Methods
Verified
Journal Article
Closed access
PDF file
Bo LiBo Li
Bo Li
CWChunyan Wu
Chunyan Wu
MWMengran Wang
Mengran Wang
KCKriti Charan
Kriti Charan
CXChris Xu
Chris Xu

5 July 2018 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
MWMengran Wang
Mengran Wang
CWChunyan Wu
Chunyan Wu
DSDavid Sinefeld
David Sinefeld
Bo LiBo Li
Bo Li
FXFei Xia
Fei Xia
CXChris Xu
Chris Xu
Light attenuation in thick biological tissues, caused by a combination of absorption and scattering, limits the penetration depth in multiphoton microscopy (MPM). Both tissue scattering and absorption are dependent on wavelengths, which makes it essential to choose the excitation wavelength with minimum attenuation for deep imaging. Although theoretical models have been established to predict the wavelength dependence of light attenuation in brain tissues, the accuracy of these models in experimental settings needs to be verified. Furthermore, the water absorption contribution to the tissue attenuation, especially at 1450 nm where strong water absorption is predicted to be the dominant contributor in light attenuation, has not been confirmed. Here we performed a systematic study of in vivo three-photon imaging at different excitation wavelengths, 1300 nm, 1450 nm, 1500 nm, 1550 nm, and 1700 nm, and quantified the tissue attenuation by calculating the effective attenuation length at each wavelength. The experimental data show that the effective attenuation length at 1450 nm is significantly shorter than that at 1300 nm or 1700 nm. Our results provide unequivocal validation of the theoretical estimations based on water absorption and tissue scattering in predicting the effective attenuation lengths for long wavelength in vivo imaging.

23 April 2018 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
KCKriti Charan
Kriti Charan
Bo LiBo Li
Bo Li
MWMengran Wang
Mengran Wang
CLCharles P. Lin
Charles P. Lin
CXChris Xu
Chris Xu
Deep tissue multiphoton imaging requires high peak power to enhance signal and low average power to prevent thermal damage. Both goals can be advantageously achieved through laser repetition rate tuning instead of simply adjusting the average power. We show that the ideal repetition rate for deep two-photon imaging in the mouse brain is between 1 and 10 MHz, and we present a fiber-based source with an arbitrarily tunable repetition rate within this range. The performance of the new source is compared to a mode-locked Ti:Sapphire (Ti:S) laser for in vivo imaging of mouse brain vasculature. At 2.5 MHz, the fiber source requires 5.1 times less average power to obtain the same signal as a standard Ti:S laser operating at 80 MHz.

19 July 2018 in Optics Express
Verified
Journal Article
Open access
PDF file
Bo LiBo Li
Bo Li
MWMengran Wang
Mengran Wang
KCKriti Charan
Kriti Charan
MLMing-Jun Li
Ming-Jun Li
CXChris Xu
Chris Xu
We explore the long wavelength limit of soliton self-frequency shift in silica-based fibers experimentally and using numerical simulation. We found that the longest wavelength soliton generated by soliton self-frequency shift is approximately 2500 nm because the soliton loses its energy rapidly at wavelength beyond 2400 nm due to material absorption by silica and water. We demonstrate 1580-2520 nm wavelength-tunable, high-pulse energy soliton generation using soliton self-frequency shift in a large-mode-area silica fiber pumped by a compact fiber source. Soliton pulses with pulse width of ~100 fs and pulse energy up to 73 nJ were obtained. Second harmonic generation of the solitons enables a wavelength-tunable femtosecond source from 950 nm to 1260 nm, with pulse energy up to 21 nJ. Using such energetic pulses, we demonstrate in vivo two-photon excited fluorescence imaging of vasculature and neurons in a mouse brain at wavelength beyond the tuning range of a mode-locked Ti:Sapphire lasers.

29 November 2018 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
FXFei Xia
Fei Xia
CWChunyan Wu
Chunyan Wu
DSDavid Sinefeld
David Sinefeld
Bo LiBo Li
Bo Li
YQYifan Qin
Yifan Qin
CXChris Xu
Chris Xu
Optical microscopy is a valuable tool for in vivo monitoring of biological structures and functions because of its non-invasiveness. However, imaging deep into biological tissues is challenging due to the scattering and absorption of light. Previous research has shown that 1300 nm and 1700 nm are the two best wavelength windows for deep brain imaging. Here, we combined long-wavelength illumination of ~1700 nm with reflectance confocal microscopy and achieved an imaging depth of ~1.3 mm with ~1-micrometer spatial resolution in adult mouse brains, which is 3-4 times deeper than that of conventional confocal microscopy using visible wavelength. We showed that the method can be added to any laser-scanning microscopy with simple and low-cost sources and detectors, such as continuous-wave diode lasers and InGaAs photodiodes. The long-wavelength, reflectance confocal imaging we demonstrated is label-free, and requires low illumination power. Furthermore, the imaging system is simple and low-cost, potentially creating new opportunities for biomedical research and clinical applications.

12 July 2006 in Optical Materials
Verified
Journal Article
Closed access
ZHZezhu Huang
Zezhu Huang
XWXiaomei Wang
Xiaomei Wang
Bo LiBo Li
Bo Li
CLChanggui Lv
Changgui Lv
JXJun Xu
Jun Xu
PYPing Yang
Ping Yang