Barbara Bennani-Baiti

Dr. Barbara Bennani-Baiti

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
BBBarbara Bennani-Baiti
Barbara Bennani-Baiti
NBNabila Bennani-Baiti
Nabila Bennani-Baiti
PBPascal A.T. Baltzer
Pascal A.T. Baltzer
To evaluate the performance of MRI for diagnosis of breast cancer in non-calcified equivocal breast findings. We performed a systematic review and meta-analysis of peer-reviewed studies in PubMed from 01/01/1986 until 06/15/2015. Eligible were studies applying dynamic contrast-enhanced breast MRI as an adjunct to conventional imaging (mammography, ultrasound) to clarify equivocal findings without microcalcifications. Reference standard for MRI findings had to be established by histopathological sampling or imaging follow-up of at least 12 months. Number of true or false positives and negatives and other characteristics were extracted, and possible bias was determined using the QUADAS-2 applet. Statistical analyses included data pooling and heterogeneity testing. Fourteen out of 514 studies comprising 2,316 lesions met our inclusion criteria. Pooled diagnostic parameters were: sensitivity (99%, 95%-CI: 93–100%), specificity (89%, 95%-CI: 85–92%), PPV (56%, 95%-CI: 42–70%) and NPV (100%, 95%-CI: 99–100%). These estimates displayed significant heterogeneity (P<0.001). Breast MRI demonstrates an excellent diagnostic performance in case of non-calcified equivocal breast findings detected in conventional imaging. However, considering the substantial heterogeneity with regard to prevalence of malignancy, problem solving criteria need to be better defined.

5 July 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
BBBarbara Bennani-Baiti
Barbara Bennani-Baiti
MDMatthias Dietzel
Matthias Dietzel
PBPascal A.T. Baltzer
Pascal A.T. Baltzer
Previously, a strong positive association between background parenchymal enhancement (BPE) at magnetic resonance imaging (MRI) and breast cancer was reported in high-risk populations. We sought to determine, whether this was also true for non-high-risk patients. 540 consecutive patients underwent breast MRI for assessment of breast findings (BI-RADS 0–5, non-high-risk screening (no familial history of breast cancer, no known genetic mutation, no prior chest irradiation, or previous breast cancer diagnosis)) and subsequent histological work-up. For this IRB-approved study, BPE and fibroglandular tissue FGT were retrospectively assessed by two experienced radiologists according to the BI-RADS lexicon. Pearson correlation coefficients were calculated to explore associations between BPE, FGT, age and final diagnosis of breast cancer. Subsequently, multivariate logistic regression analysis, considering covariate colinearities, was performed, using final diagnosis as the target variable and BPE, FGT and age as covariates. Age showed a moderate negative correlation with FGT (r = -0.43, p<0.001) and a weak negative correlation with BPE (r = -0.28, p<0.001). FGT and BPE correlated moderately (r = 0.35, p<0.001). Final diagnosis of breast cancer displayed very weak negative correlations with FGT (r = -0.09, p = 0.046) and BPE (r = -0.156, p<0.001) and weak positive correlation with age (r = 0.353, p<0.001). On multivariate logistic regression analysis, the only independent covariate for prediction of breast cancer was age (OR 1.032, p<0.001). Based on our data, neither BPE nor FGT independently correlate with breast cancer risk in non-high-risk patients at MRI. Our model retained only age as an independent risk factor for breast cancer in this setting.

30 November 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
BBBarbara Bennani-Baiti
Barbara Bennani-Baiti
MDMatthias Dietzel
Matthias Dietzel
PBPascal A.T. Baltzer
Pascal A.T. Baltzer
Assess the performance of breast MRI to diagnose breast cancer in BI-RADS 4 microcalcifications detected by mammography. This retrospective, IRB-approved study included 248 consecutive contrast-enhanced breast MRI (1.5T, protocol in accordance with EUSOBI recommendations) performed to further diagnose BI-RADS 4 microcalcifications detected at mammography during a 3-year period. Standard of reference had to be established by histopathology. Routine consensus reading results by two radiologists were dichotomized as positive or negative and compared with the reference standard (benign vs malignant) to calculate diagnostic parameters. There were 107 malignant and 141 benign microcalcifications. Malignancy rates were 18.3% (23/126 BI-RADS 4a), 41.7% (25/60 BI-RADS 4b) and 95% (59/62 BI-RADS 4c). There were 103 true-positive, 116 true-negative, 25 false-positive, and 4 false-negative (one invasive cancer, three DCIS; 2 BI-RADS 4c, 1 BI-RADS 4b on mammography) breast MRI findings, effecting a sensitivity, specificity, PPV, and NPV of 96.3% (95%-CI 90.7–99.0%), 82.3% (95%-CI 75.0–88.2%), 80.5% (95%-CI 72.5–87.0%) and 96.7% (95%-CI 91.7–99.1%), respectively. MRI is an accurate tool to further diagnose BI-RADS 4a and 4b microcalcifications and may be helpful to avoid unnecessary biopsies in BI-RADS 4a and 4b lesions. BI-RADS 4c microcalcifications should be biopsied irrespective of MRI findings.

1 December 2019 in Radiology
Verified
Journal Article
Closed access
BBBarbara Bennani-Baiti
Barbara Bennani-Baiti
BKBarbara Krug
Barbara Krug
DGDaniel Giese
Daniel Giese
MHMartin Hellmich
Martin Hellmich
SBSophie Bartsch
Sophie Bartsch
PBPascal A.T. Baltzer
Pascal A.T. Baltzer
Women at high risk for breast cancer undergoing annual breast MRI screening with relatively large cumulative doses of gadoterate dimeglumine did not exhibit T1 signal increase in either globus pall... Background Otherwise healthy women at high risk for breast cancer undergo annual contrast agent–enhanced breast MRI screening examinations, resulting in high cumulative doses of gadolinium-based co...

24 July 2020 in Cancers
Verified
Journal Article
Open access
PDF file
BBBarbara Bennani-Baiti
Barbara Bennani-Baiti
Katja Pinker-DomenigKatja Pinker-Domenig
Katja Pinker-Domenig
Max ZimmermannMax Zimmermann
Max Zimmermann
THThomas Helbich
Thomas Helbich
PBPascal A.T. Baltzer
Pascal A.T. Baltzer
Andreas StadlbauerAndreas Stadlbauer
Andreas Stadlbauer
The aim of this study was to investigate the potential of magnetic resonance imaging (MRI) for a non-invasive synergistic assessment of tumor microenvironment (TME) hypoxia and induced neovascularization for the identification of aggressive breast cancer. Fifty-three female patients with breast cancer underwent multiparametric breast MRI including quantitative blood-oxygen-level-dependent (qBOLD) imaging for hypoxia and vascular architecture mapping for neovascularization. Quantitative MRI biomarker maps of oxygen extraction fraction (OEF), metabolic rate of oxygen (MRO2), mitochondrial oxygen tension (mitoPO2), microvessel radius (VSI), microvessel density (MVD), and microvessel type indicator (MTI) were calculated. Histopathology was the standard of reference. Histopathological markers (vascular endothelial growth factor receptor 1 (FLT1), podoplanin, hypoxia-inducible factor 1-alpha (HIF-1alpha), carbonic anhydrase 9 (CA IX), vascular endothelial growth factor C (VEGF-C)) were used to confirm imaging biomarker findings. Univariate and multivariate regression analyses were performed to differentiate less aggressive luminal from aggressive non-luminal (HER2-positive, triple negative) malignancies and assess the interplay between hypoxia and neoangiogenesis markers. Aggressive non-luminal cancers (n = 40) presented with significantly higher MRO2 (i.e., oxygen consumption), lower mitoPO2 values (i.e., hypoxia), lower MTI, and higher MVD than less aggressive cancers (n = 13). Data suggest that a model derived from OEF, mitoPO2, and MVD can predict tumor proliferation rate. This novel MRI approach, which can be easily implemented in routine breast MRI exams, aids in the non-invasive identification of aggressive breast cancer.

6 December 2019 in Der Radiologe
Verified
Journal Article
Open access
PDF file
BBBarbara Bennani-Baiti
Barbara Bennani-Baiti
PBP. A. T. Baltzer
P. A. T. Baltzer
Zusammenfassung: Hintergrund: Künstliche Intelligenz (KI) wird zunehmend in der bildgebenden Mammdiagnostik eingesetzt. Fragestellung: Was sind die wesentlichen Anwendungsgebiete und bereits verfügbaren KI-gestützten Systeme auf dem Gebiet der senologischen Radiologie? Material und Methode: Zusammenfassung, übersichtliche Darstellung sowie Diskussion relevanter Daten aus Grundlagenarbeiten und Herstellerinformationen. Ergebnisse: KI-gestützte Befundsysteme sind bereits seit fast 25 Jahren in der Mammadiagnostik im Einsatz, werden jedoch in den USA weitaus häufiger angewandt als in Europa. Initiale CAD-Systeme (computergestützte Diagnostik) zeichneten sich durch eine limitierte diagnostische Aussagekraft mit überproportionalen Raten falsch-positiver Befunde aus. Seit 2012 kommen Deep–Learning-Algorithmen zum Einsatz und erweitern die Einsatzmöglichkeiten der KI. Schlussfolgerung: Derzeit gibt es keinen Algorithmus, der – nachweislich validiert – die Doppelbefundung durch zertifizierte Mammaradiologen übertrifft. In der mittelbaren Zukunft ist jedoch die Übernahme von Aufgaben durch KI absehbar: So kann die Vorselektion abnormer Studien die Arbeitslast gerade in der Früherkennung substanziell verringern. Auch die Erfassung von komplexen radiopathogenomischen Zusammenhängen und besonders ihre Translation in die klinische Praxis ist ohne KI kaum denkbar.