Evelyn Morin

Dr. Evelyn Morin

Department of Electrical and Computer Engineering, Queen’s University, Kingston, ON K7L 3N6, Canada
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2023 in Journal of Electromyography and Kinesiology
Verified
Journal Article
Closed access
ECEdward Clancy
Edward Clancy
EMEvelyn Morin
Evelyn Morin
GHGelareh Hajian
Gelareh Hajian
RMRoberto Merletti
Roberto Merletti

22 February 2022 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
GHGelareh Hajian
Gelareh Hajian
EMEvelyn Morin
Evelyn Morin
EMG-based motion estimation is required for applications such as myoelectric control, where the simultaneous estimation of kinematic information, namely joint angle and velocity, is challenging and critical. We propose a novel method for accurately modelling the generated joint angle and velocity simultaneously under isotonic, isokinetic (quasi-dynamic), and fully dynamic conditions. Our solution uses two streams of CNN, called TS-CNN to learn informative features from raw EMG data using different scales and estimate the generated motion during elbow flexion and extension. The experimental results show the robustness of our approach in comparison to conventional CNN as well as some methods used in the literature. The best obtained ${R}^{2}$ values, are 0.81±0.06, 0.71±0.06, and 0.80±0.13 for joint angle estimation and 0.78±0.05, 0.79±0.07, and 0.71±0.13 for the velocity estimation, during isotonic, isokinetic, and dynamic contractions, respectively. Additionally, our results indicate that the experimental condition can have an impact on the model’s performance for motion prediction. EMG-based velocity estimation obtains higher performance than joint angle estimation under isokinetic conditions. Under dynamic conditions, joint angle estimation is more accurate than velocity estimation, and there is no difference between joint angle and velocity estimation in the isotonic case.

9 July 2023 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
SFShane Forbrigger
Shane Forbrigger
VDVincent G. DePaul
Vincent G. DePaul
TDT Claire Davies
T Claire Davies
EMEvelyn Morin
Evelyn Morin
KHKeyvan Hashtrudi-Zaad
Keyvan Hashtrudi-Zaad
Interest in home-based stroke rehabilitation mechatronics, which includes both robots and sensor mechanisms, has increased over the past 12 years. The COVID-19 pandemic has exacerbated the existing lack of access to rehabilitation for stroke survivors post-discharge. Home-based stroke rehabilitation devices could improve access to rehabilitation for stroke survivors, but the home environment presents unique challenges compared to clinics. The present study undertakes a scoping review of designs for at-home upper limb stroke rehabilitation mechatronic devices to identify important design principles and areas for improvement. Online databases were used to identify papers published 2010–2021 describing novel rehabilitation device designs, from which 59 publications were selected describing 38 unique designs. The devices were categorized and listed according to their target anatomy, possible therapy tasks, structure, and features. Twenty-two devices targeted proximal (shoulder and elbow) anatomy, 13 targeted distal (wrist and hand) anatomy, and three targeted the whole arm and hand. Devices with a greater number of actuators in the design were more expensive, with a small number of devices using a mix of actuated and unactuated degrees of freedom to target more complex anatomy while reducing the cost. Twenty-six of the device designs did not specify their target users’ function or impairment, nor did they specify a target therapy activity, task, or exercise. Twenty-three of the devices were capable of reaching tasks, 6 of which included grasping capabilities. Compliant structures were the most common approach of including safety features in the design. Only three devices were designed to detect compensation, or undesirable posture, during therapy activities. Six of the 38 device designs mention consulting stakeholders during the design process, only two of which consulted patients specifically. Without stakeholder involvement, these designs risk being disconnected from user needs and rehabilitation best practices. Devices that combine actuated and unactuated degrees of freedom allow a greater variety and complexity of tasks while not significantly increasing their cost. Future home-based upper limb stroke rehabilitation mechatronic designs should provide information on patient posture during task execution, design with specific patient capabilities and needs in mind, and clearly link the features of the design to users’ needs.

20 November 2009 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
KMKatherine Mountjoy
Katherine Mountjoy
EMEvelyn Morin
Evelyn Morin
KHKeyvan Hashtrudi-Zaad
Keyvan Hashtrudi-Zaad
An important aspect of accurate representation of human movement is the ability to account for differences between individuals. The following paper proposes a methodology using Hill-based candidate functions in the fast orthogonal search (FOS) method to predict translational force at the wrist from flexion and extension torque at the elbow. Within this force-prediction framework, it is possible to implicitly estimate subject-specific physiological parameters of Hill-based models of upper arm muscles. Surface electromyography data from three muscles of the upper arm (biceps brachii, brachioradialis, and triceps brachii) were recorded from ten subjects, as they performed isometric contractions at varying elbow joint angles. Estimated muscle activation level and joint angle were utilized as inputs to the FOS model. Subject-specific estimates of optimal joint angles for the three muscles were determined via frequency analysis of the selected FOS candidate functions.

27 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
GHGelareh HAJIAN
Gelareh HAJIAN
AEAli Etemad
Ali Etemad
EMEvelyn Morin
Evelyn Morin
Accurate and real-time estimation of force from surface electromyogram (EMG) signals enables a variety of applications. We developed and validated new approaches for selecting subsets of high-density (HD) EMG channels for improved and lower-dimensionality force estimation. First, a large dataset was recorded from a number of participants performing isometric contractions in different postures, while simultaneously recording HD-EMG channels and ground-truth force. The EMG signals were acquired from three linear surface electrode arrays, each with eight monopolar channels, and were placed on the long head and short head of the biceps brachii and brachioradialis. After data collection and pre-processing, fast orthogonal search (FOS) was employed for force estimation. To select a subset of channels, principal component analysis (PCA) in the frequency domain and a novel index called the power-correlation ratio (PCR), which maximizes the spectral power while minimizing similarity to other channels, were used. These approaches were compared to channel selection using time-domain PCA. We selected one, two, and three channels per muscle from the original seven differential channels to reduce the redundancy and correlation in the dataset. In the best case, we achieved an approximate improvement of 30% for force estimation while reducing the dimensionality by 57% for a subset of three channels.

11 July 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
GHGelareh Hajian
Gelareh Hajian
EMEvelyn Morin
Evelyn Morin
AEAli Etemad
Ali Etemad
Accurate force/torque estimation is essential for applications such as powered exoskeletons, robotics, and rehabilitation. However, force/torque estimation under dynamic conditions is challenging due to changing joint angles, force levels, muscle lengths, and movement speeds. We propose a novel method to accurately model the generated force under isotonic, isokinetic (quasi-dynamic), and fully dynamic conditions. Our solution uses a deep multimodal convolutional neural network (CNN) to learn from multimodal electromyogram-inertial measurement unit (EMG-IMU) data and estimate the generated force for elbow flexion and extension, for both intra- and intersubject schemes. The proposed deep multimodal CNN extracts representations from EMG (in time and frequency domains) and IMU (in time domain) and aggregates them to obtain an effective embedding for force estimation. We describe a new dataset containing EMG, IMU, and output force data, collected under a number of different experimental conditions, and use this dataset to evaluate our proposed method. The results show the robustness of our approach in comparison to other baseline methods and those in the literature, in different experimental setups and validation schemes. The obtained $R^{2}$ values are 0.91 ± 0.034, 0.87 ± 0.041, and 0.81 ± 0.037 for the intrasubject and 0.81 ± 0.048, 0.64 ± 0.037, and 0.59 ± 0.042 for the intersubject scheme, during isotonic, isokinetic, and dynamic contractions, respectively. In addition, our results indicate that force estimation improves significantly when the kinematic information (IMU data) is included. Average improvements of 13.95%, 118.18%, and 50.0% (intrasubject) and 28.98%, 41.18%, and 137.93% (intersubject) for isotonic, isokinetic, and dynamic contractions, respectively, are achieved.