Xu Li

Mr. Xu Li

Southeast University, China
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2020 in IEEE Access
Verified
Journal Article
Open access
XLXu Li
Xu Li
YLYuping Lu
Yuping Lu
With the ever-increasing integration of wind power into the distribution network (DN) in the form of distributed generations (DGs), the optimal application environment for the conventional three-stage overcurrent protection no longer exists. Meanwhile, a majority of advanced protection schemes cannot be implemented due to the lack of voltage information and weak communication conditions in DN. As the most typical wind-based DG used in the DN, the doubly fed induction generator (DFIG)-based DG is focused in this paper. First, the frequency and amplitude characteristics of the fault current supplied by a DFIG-based DG are studied. Then, the amplitude differential protection (ADP) scheme is described using the weak-infeed characteristics of the DFIG-based DG. Furthermore, the frequency spectrum index, which is constructed based on the different frequency characteristics of DFIG-based DGs from synchronous generators, is introduced as a regulator factor to further improve the sensitivity of the ADP. Since only the current amplitude information is needed and the strict synchronization of the sampling data at the two ends of the line is not required, the proposed scheme is easy to implement under the limited hardware conditions in present DN. The simulation results show that the proposed scheme has a high sensitivity to the internal faults and has absolute selectivity for external faults, especially under the existing DG permeability rules.

18 March 2022 in Electric Power Systems Research
Verified
Journal Article
Closed access
XLXu Li
Xu Li
YLYuping Lu
Yuping Lu
THTao Huang
Tao Huang
JQJiaqi Qin
Jiaqi Qin
WJWentao Jiang
Wentao Jiang

1 May 2023 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
XLXu Li
Xu Li
YLYuping Lu
Yuping Lu

19 January 2022 in Electric Power Systems Research
Verified
Journal Article
Closed access
XLXu Li
Xu Li
YLYuping Lu
Yuping Lu
WJWentao Jiang
Wentao Jiang
JQJiaqi Qin
Jiaqi Qin

26 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
XLXu Li
Xu Li
YLYuping Lu
Yuping Lu
THTao Huang
Tao Huang
With high sensitivity and strong tolerance capability for the fault resistance, the fault component-based directional relay (FCBDR) has drawn considerable attention from industry and academia. However, the best application environment for FCBDR no longer exists when considering the large-scale connection of the doubly fed induction generator (DFIG)-based wind farms. Through a detailed analysis of the superimposed impedance of DFIG, this paper reveals that the performances of FCBDRs may be shown negatively impacted by the fault behaviors of DFIG when the crowbar protection inputs. In addition, this paper proposes a mitigation countermeasure to deal with those issues. The proposed countermeasure takes advantage of the different superimposed impedance features of DFIG compared with that of the synchronous generator (SG) to enhance the adaptability of the conventional FCBDRs. Extensive simulation results show that the proposed countermeasure can differentiate the fault direction clearly under different fault conditions.

28 May 2025 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
JWJiakang Wang
Jiakang Wang
XLXu Li
Xu Li
JZJiyong Zhang
Jiyong Zhang
Despite the widespread adoption of grid-forming (GFM) control in inverter-based resources (IBRs), its application in doubly fed induction generators (DFIGs) with simultaneous consideration of modern grid codes (GCs) and fault current limiting (FCL) requirements remains largely unexplored. This paper reveals that the two typical virtual impedance (VI)-based FCL methods designed for GFM-IBRs are ill-suited for GFM-DFIGs during symmetrical faults. This incompatibility is evident not only in the failure to prevent temporary overcurrent but also in the violation of modern GCs regarding the distribution and dynamic response speed of the active and reactive currents. Also, this paper proposes a novel time-sequential FCL strategy to address the demands of both FCL and GC requirements. In this proposed approach, the VI is adaptively adjusted at specific fault stages, while concurrently aligning the internal virtual electromotive force (EMF) of the GFM-DFIG with GC requirements. Simulation results conducted on a 9-bus IEEE test system and hardware-in-the-loop (HIL) testing experiments validate the enhanced alignment with emerging GC standards of the proposed FCL strategy, even under varying symmetrical voltage sags and faulty phase jumps.