Hyung Cheol Kim

Prof. Hyung Cheol Kim

Department of Neurosurgery, Yonsei University College of Medicine
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
HKHyung Cheol Kim
Hyung Cheol Kim
YJYeong Ha Jeong
Yeong Ha Jeong
SOSung Han Oh
Sung Han Oh
JLJong Min Lee
Jong Min Lee
Chang Kyu LeeChang Kyu Lee
Chang Kyu Lee
Dong  Ah ShinDong Ah Shin
Dong Ah Shin
The insertion of pedicle screws in the lateral position without a position change has been reported. We completed a retrospective comparison of the radiologic and clinical outcomes of 36 patients who underwent either single-position oblique lateral lumbar interbody fusion (SP-OLIF) using the O-arm (36 cases) or conventional OLIF (C-OLIF) using the C-arm (20 cases) for L2–5 single-level lumbar degenerative diseases. Radiological parameters were analyzed, including screw accuracy (Gertzbein-Robbins classification system; GRS), segmental instability, and fusion status. Screw misplacement was defined as a discrepancy of ≥2 mm. Clinical outcomes, including visual analog scale, Oswestry Disability Index (ODI), 36-Item Short Form Health Survey (SF-36), and postoperative complications, were assessed. The spinal fusion rate was not different between the SP-OLIF and C-OLIF groups one year after surgery (p = 0.536). The ODI score was lower (p = 0.015) in the SP-OLIF than the C-OLIF group. Physical (p = 0.000) and mental component summaries (p = 0.000) of the SF-36 were significantly higher in the SP-OLIF group. Overall complication rates, including revision, surgical site infection, ipsilateral weakness, and radicular pain/numbness, were not significantly different. SP-OLIF using the O-arm procedure is feasible, with acceptable accuracy, fusion rate, and complication rate. This may be an alternative to conventional two-stage operations.

9 January 2020 in Neurosurgical Review
Verified
Journal Article
Closed access
PDF file
HKHyung Cheol Kim
Hyung Cheol Kim
JOJae Keun Oh
Jae Keun Oh
DKDu Su Kim
Du Su Kim
JRJeffrey S. Roh
Jeffrey S. Roh
TKTae Woo Kim
Tae Woo Kim
YHYoon Ha
Yoon Ha

31 March 2024 in Neurospine
Verified
Journal Article
Open access
PDF file
YHYoon Ha Hwang
Yoon Ha Hwang
BHByeong Jin Ha
Byeong Jin Ha
HKHyung Cheol Kim
Hyung Cheol Kim
BLByung Ho Lee
Byung Ho Lee
JPJeong-Yoon Park
Jeong-Yoon Park
Seong-Tae YiSeong-Tae Yi
Seong-Tae Yi
Objective: This study aimed to compare the accuracy of robotic spine surgery and conventional pedicle screw fixation in lumbar degenerative disease. We evaluated clinical and radiological outcomes to demonstrate the noninferiority of robotic surgery.Methods: This study employed propensity score matching and included 3 groups: robot-assisted mini-open posterior lumbar interbody fusion (PLIF) (robotic surgery, RS), c-arm guided minimally invasive surgery transforaminal lumbar interbody fusion (C-arm guidance, CG), and freehand open PLIF (free of guidance, FG) (54 patients each). The mean follow-up period was 2.2 years. The preoperative spine condition was considered. Accuracy was evaluated using the Gertzbein-Robbins scale (GRS score) and Babu classification (Babu score). Radiological outcomes included adjacent segmental disease (ASD) and mechanical failure. Clinical outcomes were assessed based on the visual analogue scale, Oswestry Disability Index, 36-item Short Form health survey, and clinical ASD rate.Results: Accuracy was higher in the RS group (p < 0.01) than in other groups. The GRS score was lower in the CG group, whereas the Babu score was lower in the FG group compared with the RS group. No significant differences were observed in radiological and clinical outcomes among the 3 groups. Regression analysis identified preoperative facet degeneration, GRS and Babu scores as significant variables for radiological and clinical ASD. Mechanical failure was influenced by the GRS score and patients’ age.Conclusion: This study showed the superior accuracy of robotic spine surgery compared with conventional techniques. When combined with minimally invasive surgery, robotic surgery is advantageous with reduced ligament and muscle damage associated with traditional open procedures.

13 October 2020 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
PDF file
HKHyung Cheol Kim
Hyung Cheol Kim
HJHyeongseok Jeon
Hyeongseok Jeon
SASeong Bae An
Seong Bae An
HKHongho Kim
Hongho Kim
SHSungteac Hwang
Sungteac Hwang
Seong-Tae YiSeong-Tae Yi
Seong-Tae Yi

30 March 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
HKHyung Cheol Kim
Hyung Cheol Kim
SASeong Bae An
Seong Bae An
HJHyeongseok Jeon
Hyeongseok Jeon
TKTae Woo Kim
Tae Woo Kim
JOJae Keun Oh
Jae Keun Oh
YHYoon Ha
Yoon Ha
Cognitive status has been reported to affect the peri-operative and post-operative outcomes of certain surgical procedures. This prospective study investigated the effect of preoperative cognitive impairment on the postoperative course of elderly patients (n = 122, >65 years), following spine surgery for degenerative spinal disease. Data on demographic characteristics, medical history, and blood analysis results were collected. Preoperative cognition was assessed using the mini-mental state examination, and patients were divided into three groups: normal cognition, mild cognitive impairment, and moderate-to-severe cognitive impairment. Discharge destinations (p = 0.014) and postoperative cardiopulmonary complications (p = 0.037) significantly differed based on the cognitive status. Operation time (p = 0.049), white blood cell count (p = 0.022), platelet count (p = 0.013), the mini-mental state examination score (p = 0.033), and the Beck Depression Inventory score (p = 0.041) were significantly associated with the length of hospital stay. Our investigation demonstrated that improved understanding of preoperative cognitive status may be helpful in surgical decision-making and postoperative care of elderly patients with degenerative spinal disease.

1 September 2023 in Journal of Korean Neurosurgical Society
Verified
Journal Article
Open access
PDF file
SYSeong Bin Youn
Seong Bin Youn
GHGyojun Hwang
Gyojun Hwang
HKHyun-Gon Kim
Hyun-Gon Kim
JKJae Seong Kang
Jae Seong Kang
HKHyung Cheol Kim
Hyung Cheol Kim
SSSeung Hun Sheen
Seung Hun Sheen
Objective : Surgical site infection is the most detrimental complication following cranioplasty. In other surgical fields, intrawound vancomycin powder application has been introduced to prevent surgical site infection and is widely used based on results in multiple studies. This study evaluated the effect of intrawound vancomycin powder in cranioplasty compared with the conventional method without topical antibiotics.Methods : This retrospective study included 580 patients with skull defects who underwent cranioplasty between August 1, 1998 and December 31, 2021. The conventional method was used in 475 (81.9%; conventional group) and vancomycin powder (1 g) was applied on the dura mater and bone flap in 105 patients (18.1%; vancomycin powder group). Surgical site infection was defined as infection of the incision, organ, or space that occurred after cranioplasty. Surgical site infection within 1-year surveillance period was compared between the conventional and vancomycin powder groups with logistic regression analysis. Penalized likelihood estimation method was used in logistic regression to deal with zero events. All local and systemic adverse events associated with topical vancomycin application were also evaluated.Results : Surgical site infection occurred in 31 patients (5.3%) and all were observed in the conventional group. The median time between cranioplasty and detection of surgical site infection was 13 days (range, 4–333). Staphylococci were the most common organisms and identified in 25 (80.6%) of 31 cases with surgical site infections. The surgical site infection rate in the vancomycin powder group (0/105, 0.0%) was significantly lower than that in the conventional group (31/475, 6.5%; crude odds ratio [OR], 0.067; 95% confidence interval [CI], 0.006–0.762; adjusted OR, 0.068; 95% CI, 0.006–0.731; p=0.026). No adverse events associated with intrawound vancomycin powder were observed during the follow-up.Conclusion : Intrawound vancomycin powder effectively prevented surgical site infections following cranioplasty without local or systemic adverse events. Our results suggest that intrawound vancomycin powder is an effective and safe strategy for patients undergoing cranioplasty.