Background: Nowadays, a renewed momentum on the use of timber material is ensured by the development of high performing engineered wood products, which enables larger and taller structures to be built. Although the design of multi-story timber buildings is still in its early stages, the active interest shown by designers and researchers in advancing awareness and technologies in this field bodes well for the proliferation of an increasing number of tall wooden buildings. Objective: As a consequence of the difficulties with designing a nominally all-wooden tall structure, whilst utilizing its beneficial aspects, dual timber-concrete systems are considered in this work. In detail, the study aims to investigate the contribution of a reinforced concrete core coupled to timber stability systems for the effective control of lateral drifts in multi-storey buildings subjected to severe loading scenarios. Methods: The design of a 26-storey structural model, conceived by combining concrete cores with three design alternatives for the perimeter structure (namely a GLT frame, a CLT shear walled system and a GLT diagrid), provides the opportunity for discussing its lateral bearing capacities. Results: The building models show high lateral stiffness in withstanding seismic and wind induced loads. This result is mainly attributable to the introduction of the rigid concrete core, which nearly supplies the demand for shear and bending stresses alone. Compared to a typical cross laminated core, the concrete tube results in a stiffness increment of 68% for the frame variant, 45% for the wall variant and 23% for the diagrid variant. Therefore, the serviceability requirements, both in terms of top displacements and inter-story drifts, are inherently satisfied and kept well below the prescriptive limitations. Conclusion: The results confirm the excellent behavior of the diagrid systems, for which any variations of the inner core have almost insignificant impact on the global building performance. In addition, previous research works suggest that the timber member sizing is mainly governed by stiffness requirements, which materialize through monitoring of the lateral sway, while member strength demands are deemed to be implicitly satisfied. The paper demonstrates that strength and stiffness demands can be of equal significance during the sizing process of dual systems.
Inspired by the high mechanical performance of diagrid structures, the minimization of material consumption on braced tubes and the expressive potency of tensegrity modular structures, this work proposes an innovative three-dimensional system for tall buildings. A new modular structural system generated from the assembly of tetrahedral units is investigated. The paper integrates insights on the architectural implications and mechanical performance of the reticular system arranged in repetitive triangular-based modules. The impact of different geometric configurations of the structural members on the economic design is also discussed and recommendations for the optimal topology are made. Guidelines for the design and analytical formula for accessing preliminary member sizes are proposed on the basis of stiffness requirements.
An energy-based approach facilitates the explicit consideration of the damage associated with both maximum displacements and cumulative plastic deformations under earthquakes. For structural systems that can undergo pulse-like seismic ground motions close to causative faults, an energy-based approach is deemed especially appropriate with respect to well-established force- or displacement-based strategies. In such a case, in fact, most of the damage is attributable to the dominant pulse-like component, which usually occurs into the velocity time history of the seismic ground motion, thus implying high energy levels imparted to a structural system. In order to enable the implementation of an energy-based approach in the analysis and design of structures under near-fault pulse-like seismic ground motions, this study presents a comprehensive numerical investigation about the influence of seismological parameters and hysteretic behavior on the spectra of the following energy-related parameters: inelastic absolute and relative input energy; input energy reduction factor; hysteretic energy dissipation demand; hysteretic energy reduction factor; dimensionless cumulative plastic deformation ratio. Closed-form approximations are proposed for these spectra, and the numerical values of the corresponding parameters have been also calibrated (with reference to both mean and standard deviation values) as functions of earthquake magnitude, type of hysteretic behavior (i.e., non-degrading or degrading) and ductility level. The outcomes of this study are meant to support the derivation of design spectra for the energy-based seismic design of structures under near-fault pulse-like seismic ground motions.
2 November 2020 in The Structural Design of Tall and Special Buildings