Vânia Martins

Dr. Vânia Martins

Center for Nuclear Sciences and Technologies, Instituto Superior Técnico, University of Lisbon, Portugal
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2014 in Atmospheric Environment
Verified
Journal Article
Open access
TMT. Moreno
T. Moreno
NPNoemi Perez
Noemi Perez
CRCristina Reche
Cristina Reche
Vânia MartinsVânia Martins
Vânia Martins
EME. de Miguel
E. de Miguel
WGW. Gibbons
W. Gibbons

1 April 2015 in Science of The Total Environment
Verified
Journal Article
Open access
Vânia MartinsVânia Martins
Vânia Martins
TMTeresa Moreno
Teresa Moreno
MMMaría Cruz Minguillón
María Cruz Minguillón
FAFulvio Amato
Fulvio Amato
EMEladio de Miguel
Eladio de Miguel
XQXavier Querol
Xavier Querol
The Barcelona subway system comprises eight subway lines, at different depths, with different tunnel dimensions, station designs and train frequencies. An extensive measurement campaign was performed in this subway system in order to characterise the airborne particulate matter (PM) measuring its concentration and investigating its variability, both inside trains and on platforms, in two different seasonal periods (warmer and colder), to better understand the main factors controlling it, and therefore the way to improve air quality. The majority of PM in the underground stations is generated within the subway system, due to abrasion and wear of rail tracks, wheels and braking pads caused during the motion of the trains. Substantial variation in average PM concentrations between underground stations was observed, which might be associated to different ventilation and air conditioning systems, characteristics/design of each station and variations in the train frequency. Average PM2.5 concentrations on the platforms in the subway operating hours ranged from 20 to 51 and from 41 to 91 μg m(-3) in the warmer and colder period, respectively, mainly related to the seasonal changes in the subway ventilation systems. The new subway lines with platform screen doors showed PM2.5 concentrations lower than those in the conventional system, which is probably attributable not only to the more advanced ventilation setup, but also to the lower train frequency and the design of the stations. PM concentrations inside the trains were generally lower than those on the platforms, which is attributable to the air conditioning systems operating inside the trains, which are equipped with air filters. This study allows the analysis and quantification of the impact of different ventilation settings on air quality, which provides an improvement on the knowledge for the general understanding and good management of air quality in the subway system.

1 April 2016 in Environmental Research
Verified
Journal Article
Open access
Vânia MartinsVânia Martins
Vânia Martins
TMTeresa Moreno
Teresa Moreno
LMLuís Mendes
Luís Mendes
KEKonstantinos Eleftheriadis
Konstantinos Eleftheriadis
Evangelia DiapouliEvangelia Diapouli
Evangelia Diapouli
MMMaría Cruz Minguillón
María Cruz Minguillón
Sampling campaigns using the same equipment and methodology were conducted to assess and compare the air quality at three South European subway systems (Barcelona, Athens and Oporto), focusing on concentrations and chemical composition of PM2.5 on subway platforms, as well as PM2.5 concentrations inside trains. Experimental results showed that the mean PM2.5 concentrations widely varied among the European subway systems, and even among different platforms within the same underground system, which might be associated to distinct station and tunnel designs and ventilation systems. In all cases PM2.5 concentrations on the platforms were higher than those in the urban ambient air, evidencing that there is generation of PM2.5 associated with the subway systems operation. Subway PM2.5 consisted of elemental iron, total carbon, crustal matter, secondary inorganic compounds, insoluble sulphate, halite and trace elements. Of all metals, Fe was the most abundant, accounting for 29-43% of the total PM2.5 mass (41-61% if Fe2O3 is considered), indicating the existence of an Fe source in the subway system, which could have its origin in mechanical friction and wear processes between rails, wheels and brakes. The trace elements with the highest enrichment in the subway PM2.5 were Ba, Cu, Mn, Zn, Cr, Sb, Sr, Ni, Sn, Co, Zr and Mo. Similar PM2.5 diurnal trends were observed on platforms from different subway systems, with higher concentrations during subway operating hours than during the transport service interruption, and lower levels on weekends than on weekdays. PM2.5 concentrations depended largely on the operation and frequency of the trains and the ventilation system, and were lower inside the trains, when air conditioning system was operating properly, than on the platforms. However, the PM2.5 concentrations increased considerably when the train windows were open. The PM2.5 levels inside the trains decreased with the trains passage in aboveground sections.

1 October 2015 in Environmental Research
Verified
Journal Article
Open access
TMTeresa Moreno
Teresa Moreno
CRCristina Reche
Cristina Reche
Ioar RivasIoar Rivas
Ioar Rivas
MMMaría Cruz Minguillón
María Cruz Minguillón
Vânia MartinsVânia Martins
Vânia Martins
WGWes Gibbons
Wes Gibbons
Access to detailed comparisons in air quality variations encountered when commuting through a city offers the urban traveller more informed choice on how to minimise personal exposure to inhalable pollutants. In this study we report on an experiment designed to compare atmospheric contaminants inhaled during bus, subway train, tram and walking journeys through the city of Barcelona. Average number concentrations of particles 10-300 nm in size, N, are lowest in the commute using subway trains (N5.0×10(4) cm(-3)), with extreme transient peaks at busy traffic crossings commonly exceeding 1.0×10(5) cm(-3) and accompanied by peaks in Black Carbon and CO. Subway particles are coarser (mode 90 nm) than in buses, trams or outdoors (1200 ppm in crowded buses and trains. There are also striking differences in inhalable particle chemistry depending on the route chosen, ranging from aluminosiliceous at roadsides and near pavement works, ferruginous with enhanced Mn, Co, Zn, Sr and Ba in the subway environment, and higher levels of Sb and Cu inside the bus. We graphically display such chemical variations using a ternary diagram to emphasise how "air quality" in the city involves a consideration of both physical and chemical parameters, and is not simply a question of measuring particle number or mass.

1 February 2015 in Science of The Total Environment
Verified
Journal Article
Open access
TMTeresa Moreno
Teresa Moreno
Vânia MartinsVânia Martins
Vânia Martins
XQXavier Querol
Xavier Querol
TJTim Jones
Tim Jones
KBKelly Bérubé
Kelly Bérubé
WGWes Gibbons
Wes Gibbons
Most particles breathed on rail subway platforms are highly ferruginous (FePM) and extremely small (nanometric to a few microns in size). High magnification observations of particle texture and chemistry on airborne PM₁₀ samples collected from the Barcelona Metro, combined with published experimental work on particle generation by frictional sliding, allow us to propose a general model to explain the origin of most subway FePM. Particle generation occurs by mechanical wear at the brake-wheel and wheel-rail interfaces, where magnetic metallic flakes and splinters are released and undergo progressive atmospheric oxidation from metallic iron to magnetite and maghemite. Flakes of magnetite typically comprise mottled mosaics of octahedral nanocrystals (10-20 nm) that become pseudomorphed by maghemite. Continued oxidation results in extensive alteration of the magnetic nanostructure to more rounded aggregates of non-magnetic hematite nanocrystals, with magnetic precursors (including iron metal) still preserved in some particle cores. Particles derived from steel wheel and rails contain a characteristic trace element chemistry, typically with Mn/Fe=0.01. Flakes released from brakes are chemically very distinctive, depending on the pad composition, being always carbonaceous, commonly barium-rich, and texturally inhomogeneous, with trace elements present in nanominerals incorporated within the crystalline structure. In the studied subway lines of Barcelona at least there appears to be only a minimal aerosol contribution from high temperature processes such as sparking. To date there is no strong evidence that these chemically and texturally complex inhalable metallic materials are any more or less toxic than street-level urban particles, and as with outdoor air, the priority in subway air quality should be to reduce high mass concentrations of aerosol present in some stations.

1 January 2016 in Environmental Pollution
Verified
Journal Article
Open access
Vânia MartinsVânia Martins
Vânia Martins
TMTeresa Moreno
Teresa Moreno
MMMaría Cruz Minguillón
María Cruz Minguillón
Barend Van DroogeBarend Van Drooge
Barend Van Drooge
CRCristina Reche
Cristina Reche
XQXavier Querol
Xavier Querol
The present work assesses indoor air quality in stations of the Barcelona subway system. PM2.5 concentrations on the platforms of 4 subway stations were measured during two different seasons and the chemical composition was determined. A Positive Matrix Factorization analysis was performed to identify and quantify the contributions of major PM2.5 sources in the subway stations. Mean PM2.5 concentrations varied according to the stations design and seasonal periods. PM2.5 was composed of haematite, carbonaceous aerosol, crustal matter, secondary inorganic compounds, trace elements, insoluble sulphate and halite. Organic compounds such as PAHs, nicotine, levoglucosan and aromatic musk compounds were also identified. Subway PM2.5 source comprised emissions from rails, wheels, catenaries, brake pads and pantographs. The subway source showed different chemical profiles for each station, but was always dominated by Fe. Control actions on the source are important for the achievement of better air quality in the subway environment.