Paul Declerck

Prof. Dr. Paul Declerck

orcid

Research Focus & Metrics

Academic Career Length

44Years (1983-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
MSMachteld Sillen
Machteld Sillen
PDPaul Declerck
Paul Declerck
Plasminogen activator inhibitor-1 (PAI-1) is the main physiological inhibitor of plasminogen activators (PAs) and is therefore an important inhibitor of the plasminogen/plasmin system. Being the fast-acting inhibitor of tissue-type PA (tPA), PAI-1 primarily attenuates fibrinolysis. Through inhibition of urokinase-type PA (uPA) and interaction with biological ligands such as vitronectin and cell-surface receptors, the function of PAI-1 extends to pericellular proteolysis, tissue remodeling and other processes including cell migration. This review aims at providing a general overview of the properties of PAI-1 and the role it plays in many biological processes and touches upon the possible use of PAI-1 inhibitors as therapeutics.

1 February 2002 in The FASEB Journal
Verified
Journal Article
Open access
PDF file
LDLaetitia Devy
Laetitia Devy
SBSilvia Blacher
Silvia Blacher
CGChristine Grignet-Debrus
Christine Grignet-Debrus
KBKhalid Bajou
Khalid Bajou
VMVéronique Masson
Véronique Masson
JFJean-Michel Foidart
Jean-Michel Foidart
Plasminogen activator inhibitor 1 (PAI‐1) is believed to control proteolytic activity and cell migration during angiogenesis. We previously demonstrated in vivo that this inhibitor is necessary for optimal tumor invasion and vascularization. We also showed that PAI‐1 angiogenic activity is associated with its control of plasminogen activation but not with the regulation of cell‐matrix interaction. To dissect the role of the various components of the plasminogen activation system during angiogenesis, we have adapted the aortic ring assay to use vessels from gene‐inactivated mice. The single deficiency of tPA, uPA, or uPAR, as well as combined deficiencies of uPA and tPA, did not dramatically affect microvessel formation. Deficiency of plasminogen delayed microves‐sel outgrowth. Lack of PAI‐1 completely abolished angio‐genesis, demonstrating its importance in the control of plasmin‐mediated proteolysis. Microvessel outgrowth from PAI‐1 ‐/‐ aortic rings could be restored by adding exogenous PAI‐1 (wild‐type serum or purified recombi‐nant PAI‐1). Addition of recombinant PAI‐1 led to a bell‐shaped angiogenic response clearly showing that PAI‐1 is proangiogenic at physiological concentrations and antiangiogenic at higher levels. Using specific PAI‐1 mutants, we could demonstrate that PAI‐1 promotes an‐giogenesis at physiological (nanomolar) concentrations through its antiproteolytic activity rather than by interacting with vitronectin.—Devy, L., Blacher, S., Grignet‐Debrus, C., Bajou, K., Masson, V., Gerard, R. D., Gils, A., Carmeliet, G., Carmeliet, P., Declerck, P. J., Noèl, A., Foidart, J. M. The pro‐ or antiangiogenic effect of plasminogen activator inhibitor 1 is dose dependent. FASEB J. 16, 147–154 (2002)

KAKarolien Adriaens
Karolien Adriaens
DGDinska Van Gucht
Dinska Van Gucht
PDPaul Declerck
Paul Declerck
FBFrank Baeyens
Frank Baeyens
Background: Smoking reduction remains a pivotal issue in public health policy, but quit rates obtained with traditional quit-smoking therapies remain disappointingly low. Tobacco Harm Reduction (THR), aiming at less harmful ways of consuming nicotine, may provide a more effective alternative. One promising candidate for THR are electronic cigarettes (e-cigs). The aim of this study was to investigate the efficacy of second-generation e-cigs both in terms of acute craving-reduction in the lab and in terms of smoking reduction and experienced benefits/complaints in an eight-month Randomized Controlled Trial (RCT). Design: RCT with three arms. Methods: Participants (N = 48) unwilling to quit smoking were randomized into two e-cig groups and one control group. During three lab sessions (over two months) participants, who had been abstinent for four hours, vaped/smoked for five minutes, after which we monitored the effect on craving and withdrawal symptoms. eCO and saliva cotinine levels were also measured. In between lab sessions, participants in the e-cig groups could use e-cigs or smoke ad libitum, whereas the control group could only smoke. After the lab sessions, the control group also received an e-cig. The RCT included several questionnaires, which repeatedly monitored the effect of ad libitum e-cig use on the use of tobacco cigarettes and the experienced benefits/complaints up to six months after the last lab session. Results: From the first lab session on, e-cig use after four hours of abstinence resulted in a reduction in cigarette craving which was of the same magnitude as when a cigarette was smoked, while eCO was unaffected. After two months, we observed that 34% of the e-cig groups had stopped smoking tobacco cigarettes, versus 0% of the control group (difference p < 0.01). After five months, the e-cig groups demonstrated a total quit-rate of 37%, whereas the control group showed a quit rate of 38% three months after initiating e-cig use. At the end of the eight-month study, 19% of the e-cig groups and 25% of the control group were totally abstinent from smoking, while an overall reduction of 60% in the number of cigarettes smoked per day was observed (compared to intake). eCO levels decreased, whereas cotinine levels were the same in all groups at each moment of measurement. Reported benefits far outweighed the reported complaints. Conclusion: In a series of controlled lab sessions with e-cig naïve tobacco smokers, second generation e-cigs were shown to be immediately and highly effective in reducing abstinence induced cigarette craving and withdrawal symptoms, while not resulting in increases in eCO. Remarkable (>50 pc) eight-month reductions in, or complete abstinence from tobacco smoking was achieved with the e-cig in almost half (44%) of the participants.

22 December 2020 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
PDF file
MSMachteld Sillen
Machteld Sillen
PDPaul Declerck
Paul Declerck
Plasminogen activator inhibitor-1 (PAI-1), a member of the serine protease inhibitor (serpin) superfamily with antiprotease activity, is the main physiological inhibitor of tissue-type (tPA) and urokinase-type (uPA) plasminogen activators (PAs). Apart from being crucially involved in fibrinolysis and wound healing, PAI-1 plays a pivotal role in various acute and chronic pathophysiological processes, including cardiovascular disease, tissue fibrosis, cancer, and age-related diseases. In the prospect of treating the broad range of PAI-1-related pathologies, many efforts have been devoted to developing PAI-1 inhibitors. The use of these inhibitors, including low molecular weight molecules, peptides, antibodies, and antibody fragments, in various animal disease models has provided ample evidence of their beneficial effectin vivoand moved forward some of these inhibitors in clinical trials. However, none of these inhibitors is currently approved for therapeutic use in humans, mainly due to selectivity and toxicity issues. Furthermore, the conformational plasticity of PAI-1, which is unique among serpins, poses a real challenge in the identification and development of PAI-1 inhibitors. This review will provide an overview of the structural insights into PAI-1 functionality and modulation thereof and will highlight diverse approaches to inhibit PAI-1 activity.

2 August 2004 in Oncogene
Verified
Journal Article
Closed access
KBKhalid Bajou
Khalid Bajou
CMCatherine Maillard
Catherine Maillard
MJMaud Jost
Maud Jost
RLRoger H Lijnen
Roger H Lijnen
AGAnn Gils
Ann Gils
ANAgnes Noel
Agnes Noel

16 March 2013 in Seminars in Thrombosis and Hemostasis
Verified
Journal Article
Closed access
AGAnn Gils
Ann Gils
PDPaul Declerck
Paul Declerck
Plasminogen activator inhibitor 1 (PAI-1) is the main inhibitor of tissue-type (t-PA) and urokinase-type (u-PA) plasminogen activator and therefore plays an important role in the plasminogen–plasmin system. PAI-1 is involved in a variety of cardiovascular diseases (mainly through inhibition of t-PA) as well as in cell migration and tumor development (mainly through inhibition of u-PA and interaction with vitronectin). PAI-1 is a unique member of the serpin superfamily, exhibiting particular unique conformational and functional properties. Because of its involvement in various biologic and pathophysiologic processes, PAI-1 has been the subject of many studies, including extensive structural investigations, in vitro cell biologic studies, in vivo animal studies, and epidemiologic studies. The review provides an overview on the current knowledge on PAI-1.