Arthur Hagar

Dr. Arthur Hagar

orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
PHPatricia Hall
Patricia Hall
RRRossana Sanchez Russo
Rossana Sanchez Russo
AHArthur Hagar
Arthur Hagar
SJSalvatore Jerris
Salvatore Jerris
AWAngela Wittenauer
Angela Wittenauer
WWWilliam R. Wilcox
William R. Wilcox
We conducted a pilot newborn screening (NBS) study for Pompe disease (PD) and mucopolysaccharidosis type I (MPS I) in the multiethnic population of Georgia. We screened 59,332 infants using a two-tier strategy of flow injection tandem mass spectrometry (FIA-MSMS) enzyme assays. The first tier of testing was a 2-plex assay measuring PD and MPS I enzyme activity, followed by a second-tier test with additional enzymes to improve specificity. Interpretation of results was performed using post-analytical tools created using Collaborative Laboratory Integrated Reports (CLIR). We identified a single case of infantile onset PD, two cases of late onset PD, and one pseudodeficiency. The positive predictive value (PPV) for PD screening during the study was 66.7%. No cases of MPS I were identified during the study period, but there were 2 confirmed cases of pseudodeficiency and 6 cases lost to follow up. The two-tier screening strategy was successful in reducing false positive results and allowed for the identification and early treatment of a case of infantile PD but the frequency of pseudodeficiency in MPS I is problematic. Molecular testing is required and should be covered by the screening program to avoid delays in case resolution.

Verified
Journal Article
Open access
PDF file
PHPatricia Hall
Patricia Hall
HLHong Li
Hong Li
AHArthur Hagar
Arthur Hagar
SJSalvatore Jerris
Salvatore Jerris
AWAngela Wittenauer
Angela Wittenauer
WWWilliam Wilcox
William Wilcox
We screened 51,081 newborns for X-linked adrenoleukodystrophy (ALD) using a two-tiered strategy quantifying very long chain lysophosphatadylcholines (LPC). Our testing strategy used flow injection tandem mass spectrometry for the first-tier analysis of LPCs, and second-tier quantification of C26:0 LPC using liquid chromatography tandem mass spectrometry. There were 364 specimens considered abnormal using our first-tier algorithm that relied on the four LPC measurements and post-analytical tools. Second-tier test results were reported as normal or abnormal based on a cutoff for the single analyte, C26:0 LPC. Eleven cases were reported as abnormal based on second-tier test results. One male with ALD was identified, and two females with peroxisomal biogenesis disorders were also identified. A single female case remains unresolved, due to a loss to follow up after a negative molecular test result for ABCD1 gene sequencing. The positive predictive value for confirmed, clinically relevant disorders during this pilot study was 27.3%. Challenges identified during the study period were based around coverage for confirmatory testing, particularly if family members needed molecular testing, which is an ongoing issue with newborn screening in Georgia. We also encountered issues with the follow up for a patient who remained asymptomatic. Due to the different timelines involved with clinical findings in ALD, follow-up coordination may be more difficult, particularly if the child identified by newborn screening (NBS) is the only member of the family affected, or able to be tested.

Verified
Journal Article
Open access
PDF file
ARAlexander D. Rowe
Alexander D. Rowe
SSStephanie D. Stoway
Stephanie D. Stoway
HÅHenrik Åhlman
Henrik Åhlman
VAVaneet Arora
Vaneet Arora
MCMichele Caggana
Michele Caggana
PRPiero Rinaldo
Piero Rinaldo
Newborn screening for congenital hypothyroidism remains challenging decades after broad implementation worldwide. Testing protocols are not uniform in terms of targets (TSH and/or T4) and protocols (parallel vs. sequential testing; one or two specimen collection times), and specificity (with or without collection of a second specimen) is overall poor. The purpose of this retrospective study is to investigate the potential impact of multivariate pattern recognition software (CLIR) to improve the post-analytical interpretation of screening results. Seven programs contributed reference data (N = 1,970,536) and two sets of true (TP, N = 1369 combined) and false (FP, N = 15,201) positive cases for validation and verification purposes, respectively. Data were adjusted for age at collection, birth weight, and location using polynomial regression models of the fifth degree to create three-dimensional regression surfaces. Customized Single Condition Tools and Dual Scatter Plots were created using CLIR to optimize the differential diagnosis between TP and FP cases in the validation set. Verification testing correctly identified 446/454 (98%) of the TP cases, and could have prevented 1931/5447 (35%) of the FP cases, with variable impact among locations (range 4% to 50%). CLIR tools either as made here or preferably standardized to the recommended uniform screening panel could improve performance of newborn screening for congenital hypothyroidism.

1 June 2022 in American Journal of Medical Genetics Part C: Seminars in Medical Genetics
Verified
Journal Article
Closed access
KEKathryn Elkins
Kathryn Elkins
AWAngela Wittenauer
Angela Wittenauer
AHArthur Hagar
Arthur Hagar
RLRachel Logan
Rachel Logan
ESElizabeth Sekul
Elizabeth Sekul
WWWilliam R. Wilcox
William R. Wilcox

Verified
Journal Article
Open access
PDF file
PHPatricia Hall
Patricia Hall
AWAngela Wittenauer
Angela Wittenauer
AHArthur Hagar
Arthur Hagar
Georgia uses post-analytical tools through Collaborative Laboratory Integrated Reports (CLIR) to triage abnormal newborn screening (NBS) results for follow-up. Condition specific tools are used to assign each case a risk level, which is used to guide follow-up recommendations. Follow-up recommendations include assessment by the child’s primary care provider as well as testing, either a repeat NBS or confirmatory testing. Triaging abnormal cases using these tools has been advantageous in managing the workflow for the follow-up team, as well as prioritizing cases that appropriately require more attention and resources. The initial goal in utilizing these tools was to reduce the amount of confirmatory testing, particularly for disorders where there are many false positives. We assessed the performance of these tools retrospectively for three of the most commonly detected conditions by tandem mass spectrometry in Georgia: phenylketonuria, medium chain acyl-CoA dehydrogenase deficiency and very long chain dehydrogenase deficiency. The post-analytical tools appropriately assigned all true positive cases to the higher levels of follow-up testing and reduced the level of intervention for a significant number of cases as well. Based on the experience gained from our utilization of the tools in the follow-up program, we are well situated to move forward with using the tools in a more prospective manner, and reduce the number of cases that will be reported, rather than just assigning resources appropriately at follow-up. Post-analytical tools are an improvement over trying to capture the variation in the newborn population using multiple cutoffs. It also easily identifies significant abnormalities that are unrelated to inherited disease, such as large amino acid elevations due to total parenteral nutrition.

1 July 1991 in Journal of Leukocyte Biology
Verified
Journal Article
Closed access
PDF file
AHArthur Hagar
Arthur Hagar
ETElena B. Rodriguez de Turco
Elena B. Rodriguez de Turco
JSJudy A Spitzer
Judy A Spitzer