John Spengler

Prof. John Spengler

Exposure, Epidemiology & Risk Program, Department of Environmental Health, Harvard School of Public Health, P.O. Box 15677, Landmark 406 W, 401 Park Dr., Boston, MA 02215, USA </BR> Contact Assistant: Joan Arnold </BR> E-Mail: jarnold@hsph.harvard.edu

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 July 2015 in Current Environmental Health Reports
Verified
Journal Article
Open access
PDF file
JAJoseph G. Allen
Joseph G. Allen
PMPiers Macnaughton
Piers Macnaughton
Jose Guillermo Cedeño LaurentJose Guillermo Cedeño Laurent
Jose Guillermo Cedeño Laurent
SFSkye S. Flanigan
Skye S. Flanigan
EEErika Sita Eitland
Erika Sita Eitland
JSJohn Spengler
John Spengler
Green building design is becoming broadly adopted, with one green building standard reporting over 3.5 billion square feet certified to date. By definition, green buildings focus on minimizing impacts to the environment through reductions in energy usage, water usage, and minimizing environmental disturbances from the building site. Also by definition, but perhaps less widely recognized, green buildings aim to improve human health through design of healthy indoor environments. The benefits related to reduced energy and water consumption are well-documented, but the potential human health benefits of green buildings are only recently being investigated. The objective of our review was to examine the state of evidence on green building design as it specifically relates to indoor environmental quality and human health. Overall, the initial scientific evidence indicates better indoor environmental quality in green buildings versus non-green buildings, with direct benefits to human health for occupants of those buildings. A limitation of much of the research to date is the reliance on indirect, lagging and subjective measures of health. To address this, we propose a framework for identifying direct, objective and leading “Health Performance Indicators” for use in future studies of buildings and health.

PMPiers Macnaughton
Piers Macnaughton
JPJames Pegues
James Pegues
USUsha Satish
Usha Satish
SSSuresh Santanam
Suresh Santanam
JSJohn Spengler
John Spengler
JAJoseph G. Allen
Joseph G. Allen
Introduction: Current building ventilation standards are based on acceptable minimums. Three decades of research demonstrates the human health benefits of increased ventilation above these minimums. Recent research also shows the benefits on human decision-making performance in office workers, which translates to increased productivity. However, adoption of enhanced ventilation strategies is lagging. We sought to evaluate two of the perceived potential barriers to more widespread adoption—Economic and environmental costs. Methods: We estimated the energy consumption and associated per building occupant costs for office buildings in seven U.S. cities, representing different climate zones for three ventilation scenarios (standard practice (20 cfm/person), 30% enhanced ventilation, and 40 cfm/person) and four different heating, ventilation and air conditioning (HVAC) system strategies (Variable Air Volume (VAV) with reheat and a Fan Coil Unit (FCU), both with and without an energy recovery ventilator). We also estimated emissions of greenhouse gases associated with this increased energy usage, and, for comparison, converted this to the equivalent number of vehicles using greenhouse gas equivalencies. Lastly, we paired results from our previous research on cognitive function and ventilation with labor statistics to estimate the economic benefit of increased productivity associated with increasing ventilation rates. Results: Doubling the ventilation rate from the American Society of Heating, Refrigeration and Air-Conditioning Engineers minimum cost less than $40 per person per year in all climate zones investigated. Using an energy recovery ventilation system significantly reduced energy costs, and in some scenarios led to a net savings. At the highest ventilation rate, adding an ERV essentially neutralized the environmental impact of enhanced ventilation (0.03 additional cars on the road per building across all cities). The same change in ventilation improved the performance of workers by 8%, equivalent to a $6500 increase in employee productivity each year. Reduced absenteeism and improved health are also seen with enhanced ventilation. Conclusions: The health benefits associated with enhanced ventilation rates far exceed the per-person energy costs relative to salary costs. Environmental impacts can be mitigated at regional, building, and individual-level scales through the transition to renewable energy sources, adoption of energy efficient systems and ventilation strategies, and promotion of other sustainable policies.

1 July 2014 in Environment International
Verified
Journal Article
Closed access
JBJonathan Buonocore
Jonathan Buonocore
XDXinyi Dong
Xinyi Dong
JSJohn Spengler
John Spengler
JFJoshua S. Fu
Joshua S. Fu
JLJonathan Levy
Jonathan Levy

AWAugusta Williams
Augusta Williams
JSJohn Spengler
John Spengler
PCPaul Catalano
Paul Catalano
JAJoseph G. Allen
Joseph G. Allen
Jose Guillermo Cedeño LaurentJose Guillermo Cedeño Laurent
Jose Guillermo Cedeño Laurent
In the Northeastern U.S., future heatwaves will increase in frequency, duration, and intensity due to climate change. A great deal of the research about the health impacts from extreme heat has used ambient meteorological measurements, which can result in exposure misclassification because buildings alter indoor temperatures and ambient temperatures are not uniform across cities. To characterize indoor temperature exposures during an extreme heat event in buildings with and without central air conditioning (AC), personal monitoring was conducted with 51 (central AC, n = 24; non-central AC, n = 27) low-income senior residents of public housing in Cambridge, Massachusetts in 2015, to comprehensively assess indoor temperatures, sleep, and physiological outcomes of galvanic skin response (GSR) and heart rate (HR), along with daily surveys of adaptive behaviors and health symptoms. As expected, non-central AC units (Tmean = 25.6 °C) were significantly warmer than those with central AC (Tmean = 23.2 °C, p < 0.001). With higher indoor temperatures, sleep was more disrupted and GSR and HR both increased (p < 0.001). However, there were no changes in hydration behaviors between residents of different buildings over time and few moderate/several health symptoms were reported. This suggests both a lack of behavioral adaptation and thermal decompensation beginning, highlighting the need to improve building cooling strategies and heat education to low-income senior residents, especially in historically cooler climates.

XCXiaodong Cao
Xiaodong Cao
PMPiers Macnaughton
Piers Macnaughton
LCLeslie R. Cadet
Leslie R. Cadet
Jose Guillermo Cedeño LaurentJose Guillermo Cedeño Laurent
Jose Guillermo Cedeño Laurent
SFSkye Flanigan
Skye Flanigan
JAJoseph G. Allen
Joseph G. Allen
Pilots undergo a variety of stressors that may affect their performance during all phases of flight. Heart rate variability (HRV) has been considered as a reliable indicator of the parasympathetic and sympathetic activities of human autonomic nervous system, which can be used to characterize the sympathetic stress response of pilots during flight. In this study, thirty active commercial airline pilots were recruited to fly three flight segments in a Federal Aviation Administration (FAA)-certified A320 flight simulator with each segment at a different carbon dioxide (CO2) concentration on the flight deck. The pilots performed a series of maneuvers of varying difficulty, and their performance was evaluated by FAA designated pilot examiners. The HRV metrics (SDNN, RMSSD and LF/HF ratio) of each pilot both before and during flight simulations were measured with a Movisens EcgMove3 sensor. The average SDNN, RMSSD and LF/HF ratio of the pilots during flight simulations were 34.1 ± 12.7 ms, 23.8 ± 10.2 ms and 5.7 ± 2.8 respectively. Decreased HRV was associated with aging, obesity and performing difficult maneuvers. Both CO2 exposure and HRV had an independent effect on the pilot performance, while their interaction was not significant. The generalized additive mixed effect model results showed that a pilot performed better on a maneuver when his stress response was lower, as indicated by higher SDNN and RMSSD and lower LF/HF ratio. An interquartile range (IQR) increase in SDNN (21.97 ms) and RMSSD (16.00 ms) and an IQR decrease in LF/HF ratio (4.69) was associated with an increase in the odds of passing a maneuver by 37%, 22% and 20%, respectively.

28 March 2006 in Respiratory Research
Verified
Journal Article
Open access
Jouni J.K. JaakkolaJouni J.K. Jaakkola
Jouni J.K. Jaakkola
AKAnna A Kosheleva
Anna A Kosheleva
BKBoris Katsnelson
Boris Katsnelson
SKSergey V Kuzmin
Sergey V Kuzmin
LPLarissa I Privalova
Larissa I Privalova
JSJohn Spengler
John Spengler
Background: Only few studies have assessed the relative impact of prenatal and postnatal exposure to tobacco smoke on the child's later asthma or chronic respiratory symptoms and to our knowledge no studies have elaborated respiratory infections and allergies in this context. Objective: To assess the effects of prenatal and postnatal exposure to tobacco smoke on respiratory health of Russian school children. Methods: We studied a population of 5951 children (8 to12 years old) from 9 Russian cities, whose parents answered a questionnaire on their children's respiratory health, home environment, and housing characteristics. The main health outcomes were asthma, allergies, chronic respiratory symptoms, chronic bronchitis, and upper respiratory infections. We used adjusted odds ratios (ORs) from logistic regression analyses as measures of effect. Results: Prenatal exposure due to maternal smoking had the strongest effects on asthma (adjusted OR 2.46, 95% CI 1.19–5.08), chronic bronchitis (adjusted OR 1.45, 95% CI 1.08–1.96) and respiratory symptoms, such as wheezing (adjusted OR 1.30, 95% CI 0.90–1.89). The associations were weaker for exposure during early-life (adjusted ORs 1.38/1.27/1.15 respectively) and after 2 years of age (adjusted ORs 1.45/1.34/1.18) compared to prenatal exposure and the weakest or non-existent for current exposure (adjusted ORs 1.05/1.09/1.06). Upper respiratory infections were associated more strongly with early-life exposure (adjusted OR 1.25, 95% CI 1.09–1.42) than with prenatal (adjusted OR 0.74, 95% CI 0.54–1.01) or current exposure (adjusted OR1.05, 95% CI 0.92–1.20). The risk of allergies was also related to early life exposure to tobacco smoke (adjusted OR 1.26, 95% CI 1.13–1.42). Conclusion: Adverse effects of tobacco smoke on asthma, chronic bronchitis, and chronic respiratory symptoms are strongest when smoking takes place during pregnancy. The relations are weaker for exposure during early-life and after 2 years of age and weakest or non-existent for current exposure.