Theon the basis of the numerical solution of the equations of Navier-Stokes. The numerical solution is obtained with a finite volumemethod in the Code Saturne software package. Adequacy of the implemented model was proved by comparing the numerical solutionforVoskoboinik.spherica
This study presents the experimental and numerical validation of the Quinn fluid flow model (QFFM), a novel theoretical framework for predicting pressure drop in packed beds and closed conduits. The QFFM, derived from first principles, establishes a universal linear relationship between the normalized dimensionless pressure gradient (PQ) and fluid current (CQ), expressed as PQ=k1+k2CQ. The model bridges the gap between empirical correlations and particle-resolved simulations, offering an approach for both empty and particle-packed systems. Experimental validation was conducted using a recirculating flow loop with precise pressure and temperature measurements, while numerical simulations employed high-fidelity computational fluid dynamics model. Numerical tests were conducted for a wide range of operational and design parameters of the packed beds for two types of fluid: water and air. Results demonstrate excellent agreement between QFFM predictions and experimental data across laminar, transient, and turbulent flow regimes, with discrepancies below 3.7%. The QFFM outperforms traditional models like the Ergun equation by inherently accounting for tortuosity and microscale flow phenomena. This work highlights the model's potential for optimizing industrial packed-bed systems, providing a useful tool for engineers and researchers.
8 September 2025 in International Communications in Heat and Mass Transfer
Numerical simulation with ANSYS Fluent, Code Saturne and OpenFOAM is compared in terms of the problem of natural convection in enclosed volume of air in the presence of a heating element. A comparative analysis of software on the basis of three turbulence models (k-ε, SST and WALE) is conducted. The results adequacy is assessed. Experimental data on the temperature profile in the central section are used as a benchmark criteria. Assumptions about the destructive factors reducing the accuracy of the solution are partly supported by the results of comparative analysis of the intensity of convective up-draught. A combined turbulence model k-ω SST is used to determine the effectiveness of the implementation of the wall function in Code Saturne and OpenFOAM for mesh with variable dimensionless distance in the range of 1 <; y + <; 5 and 10 <; y + <; 50.