A new configuration of a discharge chamber and power source for the treatment of up to 1 L of liquid is presented. A leakage transformer, energizing two metal electrodes positioned above the liquid, limits the discharge current inductively by utilizing the weak magnetic coupling between the primary and secondary coils. No additional means to avoid arcing (electric short-circuiting), e.g., dielectric barriers or resistors, are needed. By using this technique, exceeding the breakdown voltage leads to the formation of transient spark discharges, producing non-thermal plasma (NTP). These discharges effected significant changes in the properties of the treated liquids (distilled water, physiological saline solution, and tap water). Considerable concentrations of nitrite and nitrate were detected after the plasma treatment. Furthermore, all tested liquids gained strong antibacterial efficacy which was shown by inactivating suspended Escherichia coli and Staphylococcus aureus. Plasma-treated tap water had the strongest effect, which is shown for the first time. Additionally, the pH-value of tap water did not decrease during the plasma treatment, and its conductivity increased less than for the other tested liquids.
Airborne bacteria are a general problem in medical or health care facilities with a high risk for nosocomial infections. Rooms with a continuous airflow, such as operation theaters, are of particular importance due to a possible dissemination and circulation of pathogens including multidrug‐resistant microorganisms. In this regard, a cold atmospheric‐pressure plasma (CAP) may be a possibility to support usual disinfection procedures due to its decontaminating properties. The aim of this study was to determine the antimicrobial efficacy of a plasma decontamination module that included a dielectric barrier discharge for plasma generation. Experimental parameters such as an airflow velocity of 4.5 m/s and microbial contaminations of approximately 6,000 colony‐forming units (cfu)/m3 were used to simulate practical conditions of a ventilation system in an operating theater. The apathogenic microorganism Escherichia coli K12 DSM 11250/NCTC 10538 and the multidrug‐resistant strains E. coli 21181 and 21182 (isolated from patients) were tested to determine the antimicrobial efficacy. In summary, the number of cfu was reduced by 31–89% for the tested E. coli strains, whereby E. coli K12 was the most susceptible strain toward inactivation by the designed plasma module. A possible correlation between the number or kind of resistances and susceptibility against plasma was discussed. The inactivation of microorganisms was affected by plasma intensity and size of the plasma treatment area. In addition, the differences of the antimicrobial efficacies caused through the nebulization of microorganisms in front (upstream) or behind (downstream) the plasma source were compared. The presence of ionic wind had no influence on the reduction of the number of cfu for E. coli K12, as the airflow velocity was too high for a successful precipitation, which would be a prerequisite for an increased antimicrobial efficacy. The inactivation of the tested microorganisms confirms the potential of CAP for the improvement of air quality. The scale‐up of this model system may provide a novel tool for an effective air cleaning process.
23 December 2009 in Biotechnology and Applied Biochemistry
Oxidative C–N bond formation followed by cyclization of dihydroxybenzoic acid derivatives with aromatic and heteroaromatic amines was catalyzed in the presence of oxygen by laccases [E.C. 1.10.3.2] from the white rot fungi Pycnoporus cinnabarinus and Myceliophthora thermophila. The laccase-catalyzed formation of cycloheptenes, cyclooctenes, diazaspiro cyclohexenes, and phenazines was investigated for the first time with regard to the ring size and substituents of the aromatic amines as well as to the substitution patterns of the substrates. Differences to C–N bond formation without cyclization are discussed.
Laccases [E.C. 1.10.3.2, benzenediol:dioxygen oxidoreductase] can oxidize phenolic substances, e.g. di- and polyphenols, hydroxylated biaryls, aminophenols or aryldiamines. This large substrate spectrum is the basis for various reaction possibilities, which include depolymerization and polymerization reactions, but also the coupling of different substance classes. To catalyze these reactions, laccases demand only atmospheric oxygen and no depletive cofactors. The utilization of mild and environmentally friendly reaction conditions such as room temperature, atmospheric pressure, and the avoidance of organic solvents makes the laccase-mediated reaction a valuable tool in green chemistry for the synthesis of biologically active compounds such as antimicrobial substances. In particular, the production of novel antibiotics becomes vital due to the evolution of antibiotic resistances amongst bacteria and fungi. Therefore, laccase-mediated homo- and heteromolecular coupling reactions result in derivatized or newly synthesized antibiotics. The coupling or derivatization of biologically active compounds or its basic structures may allow the development of novel pharmaceuticals, as well as the improvement of efficacy or tolerability of an already applied drug. Furthermore, by the laccase-mediated coupling of two different active substances a synergistic effect may be possible. However, the coupling of compounds that have no described efficacy can lead to biologically active substances by means of laccase. The review summarizes laccase-mediated reactions for the synthesis of antimicrobial compounds valuable for medical purposes. In particular, reactions with two different reaction partners were shown in detail. In addition, studies with in vitro and in vivo experimental data for the confirmation of the antibacterial and/or antifungal efficacy of the products, synthesized with laccase, were of special interest. Analyses of the structure–activity relationship confirm the great potential of the novel compounds. These substances may represent not only a value for pharmaceutical and chemical industry, but also for other industries due to a possible functionalization of surfaces such as wood or textiles.