Justus Reunanen

Dr. Justus Reunanen

Cancer and Translational Medicine Research Unit & Biocenter Oulu, University of Oulu, Oulu, Finland

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2022 in Polymers
Verified
Journal Article
Open access
PDF file
SSSonia Sarfraz
Sonia Sarfraz
PMPilvi-Helinä Mäntynen
Pilvi-Helinä Mäntynen
MLMarisa Laurila
Marisa Laurila
SRSami Rossi
Sami Rossi
JLJunnu Leikola
Junnu Leikola
JRJustus Reunanen
Justus Reunanen
This study investigated two of the most commonly used CAD–CAM materials for patient-specific reconstruction in craniomaxillofacial surgery. The aim of this study was to access the biofilm formation of Staphylococcus aureus, Streptococcus mutans, Enterococcus faecalis, and Escherichia coli on titanium and PEEK medical implant materials. Two titanium specimens (titanium grade 2 tooled with a Planmeca CAD–CAM milling device and titanium grade 5 tooled with a computer-aided design direct metal laser sintering device (CAD-DMLS)) and one PEEK specimen tooled with a Planmeca CAD–CAM milling device were studied. Bacterial adhesion on implants was evaluated in two groups (saliva-treated group and non-saliva-treated group) to imitate intraoral and extraoral surgical routes for implant placement. The PEEK medical implant material showed higher bacterial adhesion by S. aureus, S. mutans, and E. coli than titanium grade 2 and titanium grade 5, whereas E. faecalis showed higher adhesion to titanium as compared to PEEK. Saliva contamination of implants also effected bacterial attachment. Salivary coating enhanced biofilm formation by S. aureus, S. mutans, and E. faecalis. In conclusion, our findings imply that regardless of the implant material type or tooling techniques used, salivary coating plays a vital role in bacterial adhesion. In addition, the majority of the bacterial strains showed higher adhesion to PEEK than titanium.

29 October 2021 in Cancers
Verified
Journal Article
Open access
PDF file
SASAJEEN BAHADUR AMATYA
SAJEEN BAHADUR AMATYA
SSSonja Salmi
Sonja Salmi
VKVeera Kainulainen
Veera Kainulainen
PKPeeter Karihtala
Peeter Karihtala
JRJustus Reunanen
Justus Reunanen
Bacterial extracellular vesicles are membrane-enclosed, lipid bi-layer nanostructures that carry different classes of biomolecules, such as nucleic acids, lipids, proteins, and diverse types of small molecular metabolites, as their cargo. Almost all of the bacteria in the gut secrete extracellular vesicles to assist them in competition, survival, material exchange, host immune modulation, infection, and invasion. The role of gut microbiota in the development, progression, and pathogenesis of gastrointestinal tract (GIT) cancer has been well documented. However, the possible involvement of bacterial extracellular vesicles (bEVs) in GIT cancer pathophysiology has not been given due attention. Studies have illustrated the ability of bEVs to cross physiological barriers, selectively accumulate near tumor cells, and possibly alter the tumor microenvironment (TME). A systematic search of original published works related to bacterial extracellular vesicles on gastrointestinal cancer was performed for this review. The current systemic review outlines the possible impact of gut microbiota derived bEVs in GIT cancer in light of present-day understanding. The necessity of using advanced sequencing technologies, such as genetic, proteomic, and metabolomic investigation methodologies, to facilitate an understanding of the interrelationship between cancer-associated bacterial vesicles and gastrointestinal cancer is also emphasized. We further discuss the clinical and pharmaceutical potential of bEVs, along with future efforts needed to understand the mechanism of interaction of bEVs in GIT cancer pathogenesis.

22 February 2021 in Materials
Verified
Journal Article
Open access
PDF file
JHJenni Hjerppe
Jenni Hjerppe
SRSampo Rodas
Sampo Rodas
JKJohanna Korvala
Johanna Korvala
PPPaula Pesonen
Paula Pesonen
AKAnna Kaisanlahti
Anna Kaisanlahti
JRJustus Reunanen
Justus Reunanen
The aim of this study was to evaluate the surface roughness of fixed prosthodontic materials after polishing or roughening with a stainless steel curette or ultrasonic scaler and to examine the effect of these on Streptococcus mutans adhesion and biofilm accumulation. Thirty specimens (10 × 10 × 3 mm3) of zirconia (Zr), pressed lithium disilicate (LDS-Press), milled lithium disilicate glazed (LDS-Glaze), titanium grade V (Ti) and cobalt-chromium (CoCr) were divided into three groups (n = 10) according to surface treatment: polished (C), roughened with stainless steel curette (SC), roughened with ultrasonic scaler (US). Surface roughness values (Sa, Sq) were measured with a spinning disc confocal microscope, and contact angles and surface free energy (SFE) were measured with a contact angle meter. The specimens were covered with sterilized human saliva and immersed into Streptococcus mutans suspensions for bacterial adhesion. The biofilm was allowed to form for 24 h. Sa values were in the range of 0.008–0.139 µm depending on the material and surface treatment. Curette and ultrasonic scaling increased the surface roughness in LDS-Glaze (p < 0.05), Ti (p < 0.01) and CoCr (p < 0.001), however, surface roughness did not affect bacterial adhesion. Zr C and US had a higher bacterial adhesion percentage compared to LDS-Glaze C and US (p = 0.03). There were no differences between study materials in terms of biofilm accumulation.

19 October 2022 in Cancers
Verified
Journal Article
Open access
PDF file
SMSurbhi Mishra
Surbhi Mishra
SASAJEEN BAHADUR AMATYA
SAJEEN BAHADUR AMATYA
SSSonja Salmi
Sonja Salmi
VKVesa Koivukangas
Vesa Koivukangas
PKPeeter Karihtala
Peeter Karihtala
JRJustus Reunanen
Justus Reunanen
Cancer is a deadly disease worldwide. In light of the requisite of convincing therapeutic methods for cancer, immune checkpoint inhibition methods such as anti-PD-1/PD-L1 therapy appear promising. Human microbiota have been exhibited to regulate susceptibility to cancer as well as the response to anti-PD-1/PD-L1 therapy. However, the probable contribution of bacterial extracellular vesicles (bEVs) in cancer pathophysiology and treatment has not been investigated much. bEVs illustrate the ability to cross physiological barriers, assemble around the tumor cells, and likely modify the tumor microenvironment (EVs). This systematic review emphasizes the correlation between cancer-associated extracellular vesicles, particularly bEVs and the efficacy of anti-PD-1/PD-L1 therapy. The clinical and pharmacological prospective of bEVs in revamping the contemporary treatments for cancer has been further discussed.
1

5 May 2023
Verified
Book Chapter
Closed access
PDF file
NBNadiya Byts
Nadiya Byts
OMOlha Makieieva
Olha Makieieva
AZArtem Zhyvolozhnyi
Artem Zhyvolozhnyi
GBGenevieve Bart
Genevieve Bart
JKJohanna Korvala
Johanna Korvala
JRJustus Reunanen
Justus Reunanen

29 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
SSSonia Sarfraz
Sonia Sarfraz
PMPilvi-Helinä Mäntynen
Pilvi-Helinä Mäntynen
MLMarisa Laurila
Marisa Laurila
Juho SuojanenJuho Suojanen
Juho Suojanen
JSJuha Saarnio
Juha Saarnio
JRJustus Reunanen
Justus Reunanen
The aim of this study was to assess the biofilm formation of Streptococcus mutans, Staphylococcus aureus, Enterococcus faecalis, and Escherichia coli on titanium implants with CAD-CAM tooling techniques. Twenty specimens of titanium were studied: Titanium grade 2 tooled with a Planmeca CAD-CAM milling device (TiGrade 2), Ti6Al4V grade 5 as it comes from CAD-DMLS device (computer aided design-direct metal laser sintering device) (TiGrade 5), Ti6Al4V grade 23 as it comes from a CAD-CAM milling device (TiGrade 23), and CAD-DMLS TiGrade 5 polished with an abrasive disc (TiGrade 5 polished). Bacterial adhesion on the implants was completed with and without saliva treatment to mimic both extraoral and intraoral surgical methods of implant placement. Five specimens/implant types were used in the bacterial adhesion experiments. Autoclaved implant specimens were placed in petri plates and immersed in saliva solution for 30 min at room temperature and then washed 3× with 1× PBS. Bacterial suspensions of each strain were made and added to the specimens after saliva treatment. Biofilm was allowed to form for 24 h at 37 °C and the adhered bacteria was calculated. Tooling techniques had an insignificant effect on the bacterial adhesion by all the bacterial strains studied. However, there was a significant difference in biofilm formation between the saliva-treated and non-saliva-treated implants. Saliva contamination enhanced S. mutans, S. aureus, and E. faecalis adhesion in all material types studied. S. aureus was found to be the most adherent strain in the saliva-treated group, whereas E. coli was the most adherent strain in the non-saliva-treated group. In conclusion, CAD-CAM tooling techniques have little effect on bacterial adhesion. Saliva coating enhances the biofilm formation; therefore, saliva contamination of the implant must be minimized during implant placement. Further extensive studies are needed to evaluate the effects of surface treatments of the titanium implant on soft tissue response and to prevent the factors causing implant infection and failure.