Amizon Azizan

Dr. Amizon Azizan

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2013 in Biotechnology and Bioengineering
Verified
Journal Article
Closed access
PDF file
HGHeiner Giese
Heiner Giese
AAAmizon Azizan
Amizon Azizan
AKAnne Kümmel
Anne Kümmel
ALAnping Liao
Anping Liao
CPCyril P. Peter
Cyril P. Peter
JBJochen Büchs
Jochen Büchs

27 January 2022 in Environmental Science and Pollution Research
Verified
Journal Article
Closed access
PDF file
AAAmizon Azizan
Amizon Azizan
ASAisyah Afiqah Samsudin
Aisyah Afiqah Samsudin
MBMinhalina Batrisyia Shamshul Baharin
Minhalina Batrisyia Shamshul Baharin
MDMuhammad Harith Dzulkiflee
Muhammad Harith Dzulkiflee
NRNor Roslina Rosli
Nor Roslina Rosli
MAMuhammad Adlim
Muhammad Adlim

30 November 2024 in Biotechnology and Bioengineering
Verified
Journal Article
Open access
CDCarl Dinter
Carl Dinter
AGAndreas Gumprecht
Andreas Gumprecht
MMMatthias Alexander Menze
Matthias Alexander Menze
AAAmizon Azizan
Amizon Azizan
SHSven Hansen
Sven Hansen
JBJochen Büchs
Jochen Büchs
Culture broth with secreted macromolecules and culture broth of filamentous fungi showing disperse growth exhibit elevated viscosity, usually with shear‐thinning flow behavior. High viscosity, however, poses a serious challenge in the production and research of these compounds and organisms. It commonly causes insufficient mixing and oxygen transfer in large‐ and small‐scale bioreactors. Computational Fluid dynamics (CFD) has been proven to be a valuable tool for the computation of important bioprocess parameters. The published literature for small‐scale shaken bioreactors, especially shake flasks, however, almost exclusively focuses on water‐like viscosity. In this paper, a previously published CFD model for 250 mL shake flasks was used to simulate experiments at high viscosities of up to 100 mPa·s. Compared to experimental data, the CFD model accurately predicted the liquid distribution and computed the volumetric power input with a deviation of less than 7% and the kLa value within a factor of two, compared to the kLa correlation from Henzler and Schedel. Furthermore, a novel approach to compute the shear rate was tested. Lastly, new insights into the out‐of‐phase phenomenon were gained. The presented data confirms the usefulness of the already established critical phase numbers of 0.91 and 1.26, while underlying the fundamentally smooth transition from in‐phase to out‐of‐phase operating conditions.

3 August 2017 in Journal of Biological Engineering
Verified
Journal Article
Open access
PDF file
AAAmizon Azizan
Amizon Azizan
JBJochen Büchs
Jochen Büchs
Biotechnological development in shake flask necessitates vital engineering parameters e.g. volumetric power input, mixing time, gas liquid mass transfer coefficient, hydromechanical stress and effective shear rate. Determination and optimization of these parameters through experiments are labor-intensive and time-consuming. Computational Fluid Dynamics (CFD) provides the ability to predict and validate these parameters in bioprocess engineering. This work provides ample experimental data which are easily accessible for future validations to represent the hydrodynamics of the fluid flow in the shake flask. A non-invasive measuring technique using an optical fluorescence method was developed for shake flasks containing a fluorescent solution with a waterlike viscosity at varying filling volume (VL = 15 to 40 mL) and shaking frequency (n = 150 to 450 rpm) at a constant shaking diameter (do = 25 mm). The method detected the leading edge (LB) and tail of the rotating bulk liquid (TB) relative to the direction of the centrifugal acceleration at varying circumferential heights from the base of the shake flask. The determined LB and TB points were translated into three-dimensional (3D) circumferential liquid distribution plots. The maximum liquid height (Hmax) of the bulk liquid increased with increasing filling volume and shaking frequency of the shaking flask, as expected. The toroidal shapes of LB and TB are clearly asymmetrical and the measured TB differed by the elongation of the liquid particularly towards the torus part of the shake flask. The 3D liquid distribution data collected at varying filling volume and shaking frequency, comprising of LB and TB values relative to the direction of the centrifugal acceleration are essential for validating future numerical solutions using CFD to predict vital engineering parameters in shake flask.

27 July 2019 in Biotechnology and Bioengineering
Verified
Journal Article
Closed access
PDF file
AAAmizon Azizan
Amizon Azizan
MSMichaela Sieben
Michaela Sieben
GWGeorg Wandrey
Georg Wandrey
JBJochen Büchs
Jochen Büchs

1 February 2025 in Journal of Ionic Liquids
Verified
Journal Article
Open access
AAAmizon Azizan
Amizon Azizan
RDRosmaria Abu Darim
Rosmaria Abu Darim
IAIntan Suhada Azmi
Intan Suhada Azmi
RJRafidah Jalil
Rafidah Jalil
SMShareena Fairuz Abdul Manaf
Shareena Fairuz Abdul Manaf