At this time the cost for energy is already significant in the operational costs of an accommodation in a tourist village. This research is a modelling analysis to obtain a Net Zero Energy system with the application of automation system in increasing energy savings for tourism accommodation in several tourist villages as a case study. The energy used is sourced from a combination of solar energy and electric national grid. Significant energy saving strategies and efforts in traditional Balinese buildings will also be analysed in this study. Further analysis of the data obtained will be compared with the reference green building model so that the model can be applied to achieve every traditional Balinese style building in implementing green building standards. The expected result of this research is to obtain an energy saving system with the Internet of Thing (IoT) application in Bali which is used as tourism accommodation as well as energy saving procedures from the aspect of equipment and occupant behaviour.
20 January 2024 in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
The adsorption cooling system is an environmentally friendly system because of non-CFCs (chlorofluorocarbons) and non-HCFCs (hydrochlorofluorocarbons). The simulation developed is an adsorption system that can operate with a low temperature waste heat source so that this adsorption system can be applied to building cooling systems. The purpose of this research is to obtain the most effective and efficient cycle of three bed silica gel-water adsorption system with a low temperature heat source so that it has the potential for building applications. The method developed is by simulating various design combinations of three bed adsorption systems and simulating 6 (six) cycle types. Furthermore, those designs of silica gel-water based two different types of three-bed adsorption chiller has been analyzed statically. The performance of the chillers was investigated in terms of coefficient of performance (COP) and specific cooling effect (SCE) for heat source temperature between 60oC and 90oC. The result first shows that the performance data of the proposed chillers (Cycle E and Cycle F) were compared with those of other four different types of three-bed adsorption chiller with the same operating conditions. It was observed that the proposed chillers provided a higher SCE compared with other four assorted chillers. Second result show that The Cycle B obtained the higher COP comparing with the other cycles designed in this study. Thus, this system has a good potential to be developed for building cooling systems by utilizing heat waste.
The adsorption refrigeration system is a cooling system that offers several benefits, including being environmentally friendly due to the very small amount of global warming effect given, the lack of potential for ozone depletion, the low energy consumption of its operation, the low heat source used in its operationand good for reducing gas emissions on earth.This paper describes a combined reheating adsorption refrigeration system with three heat exchangers, as well as operating modes. The operation of the adsorption refrigeration system with combined reheating is schematically described with operational modes and diagrams. This adsorption cooling system is made up of three heat exchangers (H), one evaporator, and one condenser.The combination cycle is intended for heat exchanger systems that operate in a reheat cycle (H1 and H2) and a non-reheating cycle (H3). This paper also discusses system cycle time optimization.Research to get the optimum value of cycle time in this system is still rarely done and therefore optimization of cycle time is carried out on the system to get the best performance.The PSO (particle swarm optimization) program is paired with the MATLAB program to simulate the performance of the system under discussion while also enhancing its performance.The goal of this work is to use simulation to determine the optimal system performance versus the overall cycle time, which includes adsorption/desorption time, pre-cooling and pre-heating time as well as mass recovery time.Getting the best value for the entire cycle time is made possible by fusing the simulation of the system's process performance with performance optimization. As a results, the greatest increase in the optimization results' performance value occurs at a heat source temperature of 55ºC with a longer time to achieve optimal performance.
Kawasan Wisata Subak Teba Majelangu di Desa Kesiman Kertalangu terletak di wilayah dengan keterbatasan jaringan listrik. Minimnya pencahayaan di jalan-jalan daerah ini mengakibatkan terganggunya kenyamanan dan keamanan dalam beraktivitas, terutama saat sore menjelang malam hari. Berdasarkan kondisi tersebut tim pengabdian dari Prodi Teknologi Rekayasa Utilitas Jurusan Teknik Mesin Politeknik Negeri Bali melakukan Pengabdian kepada Masyarakat (PkM) dengan menyediakan lampu penerangan jalan tenaga surya di kawasan Wisata Edukasi Subak Teba Majelangu. Kegiatan PkM melewati serangkaian tahapan sebagai berikut : 1) analisis situasi, 2) penentuan kebutuhan daya lampu, 3) persiapan peralatan, 4) instalasi dan pemeliharaan, 5) evaluasi dan monitoring. Hasil yang dicapai adalah pemasangan lampu penerangan jalan tenaga surya di kawasan Wisata Edukasi Subak Teba Majelangu Desa Kesiman Kertalangu, yang mampu memberikan penerangan yang memadai di malam hari untuk jalan dan area sekitarnya, serta memiliki durasi pencahayaan yang panjang. Pemasangan lampu penerangan jalan tenaga surya merupakan implementasi penggunaan energi terbarukan dalam upaya pelestarian lingkungan..
Processing household liquid waste is a significant environmental challenge, especially in urban areas with high population density. This research aims to develop and test a prototype of an innovative small-scale biofilter system for processing household liquid waste. We designed this prototype to be an efficient, environmentally friendly, and user-friendly solution for the general public. The bio-filter prototype consists of several main components, including a biological filter with decomposing bacterial media, an aeration system, and a physical filtration layer. This study involved the creation of a prototype to handle household liquid waste. We will use this prototype design in the future to ascertain the safety level of household liquid waste for environmental disposal.
Energy in buildings in tropical regions such as Indonesia is dominated by air conditioning systems. With the high use of electrical energy from tourism accommodation, it will be difficult to develop because operational costs are high. Thus, the purpose of this research is to obtain energy savings from operational utilities used such as air conditioning, refrigerators, water heaters, pumps and lights. The saving system is carried out with an internet-based automation system so that it can be controlled properly and can influence the occupants’ energy-saving culture. The method used is the application of an energy saving model with internet-based automation. Experimental rig is made to automatically simulate energy saving. The expected result is significant energy savings in the simulated room compared to the conventional one. With a good automatic operational system, it will be able to change the energy-saving behavior of occupants.