Sven Kaese

Dr. Sven Kaese


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ASAlexander Samol
Alexander Samol
KBKristina Bischof
Kristina Bischof
BLBlerim Luani
Blerim Luani
DPDan Pascut
Dan Pascut
MWMarcus Wiemer
Marcus Wiemer
SKSven Kaese
Sven Kaese
Background: Smartwatches that are able to record a bipolar ECG and Einthoven leads were recently described. Nevertheless, for detection of ischemia or other cardiac diseases more leads are required, especially Wilson’s chest leads. Objectives: Feasibility study of six single-lead smartwatch (Apple Watch Series 4) ECG recordings including Einthoven (I, II, III) and Wilson-like pseudo-unipolar chest leads (Wr, Wm, Wl). Methods: In 50 healthy subjects (16 males; age: 36 ± 11 years, mean ± SD) without known cardiac disorders, a standard 12-lead ECG and a six single-lead ECG using an Apple Watch Series 4 were performed under resting conditions. Recording of Einthoven I was performed with the watch on the left wrist and the right index finger on the crown, Einthoven II was recorded with the watch on the left lower abdomen and the right index finger on the crown, Einthoven III was recorded with the watch on the left lower abdomen and the left index finger on the crown. Wilson-like chest leads were recorded corresponding to the locations of V1 (Wr), V4 (Wm) and V6 (Wl) in the standard 12-lead ECG. Wr was recorded in the fourth intercostal space right parasternal, Wm was recorded in the fifth intercostal space on the midclavicular line, and Wl was recorded in the fifth intercostal space in left midaxillary line. For all Wilson-like chest lead recordings, the smartwatch was placed on the described three locations on the chest, the right index finger was placed on the crown and the left hand encompassed the right wrist. Both hands and forearms also had contact to the chest. Three experienced cardiologists were independently asked to allocate three bipolar limb smartwatch ECGs to Einthoven I–III leads, and three smartwatch Wilson-like chest ECGs (Wr, Wm, Wl) to V1, V4 and V6 in the standard 12-lead ECG for each subject. Results: All 300 smartwatch ECGs showed a signal quality useable for diagnostics with 281 ECGs of good signal quality (143 limb lead ECGs (95%), 138 chest lead ECGs (92%). Nineteen ECGs had a moderate signal quality (7 limb lead ECGs (5%), 12 chest lead ECGs (8%)). One-hundred percent of all Einthoven and 92% of all Wilson-like smartwatch ECGs were allocated correctly to corresponding leads from 12-lead ECG. Forty-six subjects (92%) were assigned correctly by all cardiologists. Allocation errors were due to similar morphologies and amplitudes in at least two of the three recorded Wilson-like leads. Despite recording with a bipolar smartwatch device, morphology of all six leads was identical to standard 12-lead ECG. In two patients with acute anterior myocardial infarction, all three cardiologists recognized the ST-elevations in Wilson-like leads and assumed an occluded left anterior descending coronary artery correctly. Conclusion: Consecutive recording of six single-lead ECGs including Einthoven and Wilson-like leads by a smartwatch is feasible with good ECG signal quality. Thus, this simulated six-lead smartwatch ECG may be useable for the detection of cardiac diseases necessitating more than one ECG lead like myocardial ischemia or more complex cardia arrhythmias.

30 June 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ASAlexander Samol
Alexander Samol
KBKristina Bischof
Kristina Bischof
BLBlerim Luani
Blerim Luani
DPDan Pascut
Dan Pascut
MWMarcus Wiemer
Marcus Wiemer
SKSven Kaese
Sven Kaese
Aims: Feasibility study of accurate three lead ECG recording (Einthoven I, II and III) using an Apple Watch Series 4. Methods: In 50 healthy subjects (18 male; age: 40 ± 12 years) without known cardiac disorders, a 12-lead ECG and three bipolar ECGs, corresponding to Einthoven leads I, II and III were recorded using an Apple Watch Series 4. Einthoven I was recorded with the watch on the left wrist and the right index finger on the crown, Einthoven II with the watch on the left lower abdomen and the right index finger on the crown, Einthoven III with the watch on the left lower abdomen and the left index finger on the crown. Four experienced cardiologists were independently asked to assign the watch ECGs to Einthoven leads from 12-lead ECG for each subject. Results: All watch ECGs showed an adequate signal quality with 134 ECGs of good (89%) and 16 of moderate signal quality (11%). Ninety-one percent of all watch ECGs were assigned correctly to corresponding leads from 12-lead ECG. Thirty-nine subjects (78%) were assigned correctly by all cardiologists. All assignment errors occurred in patients with similar morphologies and amplitudes in at least two of the three recorded leads. Erroneous assignment of all watch ECGs to leads from standard ECG occurred in no patient. Conclusion: Recording of Einthoven leads I-III by a smartwatch is accurate and highly comparable to standard ECG. This might contribute to an earlier detection of cardiac disorders, which are associated with repolarization abnormalities or arrhythmias.

31 October 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MVMathini Vaseekaran
Mathini Vaseekaran
SKSven Kaese
Sven Kaese
Dennis GörlichDennis Görlich
Dennis Görlich
MWMarcus Wiemer
Marcus Wiemer
ASAlexander Samol
Alexander Samol
Background: Smart devices that are able to measure blood pressure (BP) are valuable for hypertension or heart failure management using digital technology. Data regarding their diagnostic accuracy in comparison to standard noninvasive measurement in accordance to Riva-Rocci are sparse. This study compared a wearable watch-type oscillometric BP monitor (Omron HeartGuide), a wearable watch-type infrared BP monitor (Smart Wear), a conventional ambulatory BP monitor, and auscultatory sphygmomanometry. Methods: Therefore, 159 consecutive patients (84 male, 75 female, mean age 64.33 ± 16.14 years) performed observed single measurements with the smart device compared to auscultatory sphygmomanometry (n = 109) or multiple measurements during 24 h compared to a conventional ambulatory BP monitor on the upper arm (n = 50). The two BP monitoring devices were simultaneously worn on the same arm throughout the monitoring period. In a subgroup of 50 patients, single measurements were also performed with an additional infrared smart device. Results: The intraclass correlation coefficient (ICC) between the difference and the mean of the oscillometric Omron HeartGuide and the conventional method for the single measurement was calculated for both systole (0.765) and diastole (0.732). This is exactly how the ICC was calculated for the individual mean values calculated over the 24 h long-term measurement of the individual patients for both systole (0.880) and diastole (0.829). The ICC between the infrared device and the conventional method was “bad” for SBP (0.329) and DBP (0.025). Therefore, no further long-term measurements were performed with the infrared device. Conclusion: The Omron HeartGuide device provided comparable BP values to the standard devices for single and long-term measurements. The infrared smart device failed to acquire valid measurement data.

5 May 2025 in Bioengineering
Verified
Journal Article
Open access
MVMathini Vaseekaran
Mathini Vaseekaran
MWMarcus Wiemer
Marcus Wiemer
SKSven Kaese
Sven Kaese
Dennis GörlichDennis Görlich
Dennis Görlich
JHJochen Hinkelbein
Jochen Hinkelbein
ASAlexander Samol
Alexander Samol
Background: Monitoring pulse rate is fundamental to cardiovascular health management and early detection of rhythm disturbances. While oscillometric blood pressure measurement is well established and validated in clinical practice, its use for pulse rate monitoring, particularly via wrist-worn devices, remains largely unexplored. Objective: This study investigates whether a smartwatch that performs oscillometric blood pressure measurements at the wrist can also deliver reliable pulse rate readings using the same method. Methods: This study compared pulse rates recorded by the Omron HeartGuide smartwatch and conventional ambulatory blood pressure monitors in 50 patients over 24 h. Measurements were taken consecutively, and data were analyzed using intraclass correlation coefficients (ICCs) and Bland–Altman plots. Results: The study showed a high ICC of 0.971, indicating excellent agreement between devices. The average pulse rate difference was 1.5 bpm, with the Omron HeartGuide reporting slightly lower rates, especially in patients with atrial fibrillation. Conclusions: This study demonstrates that oscillometric pulse-rate monitoring at the wrist can achieve a high degree of accuracy, comparable to conventional upper-arm devices. Given that oscillometric smartwatches like the Omron HeartGuide are already used for blood pressure monitoring, the findings suggest that they may also be suitable for pulse rate measurement, potentially enhancing their role in telemetric healthcare, but further research is needed, particularly in patients with arrhythmias.