This communication reports an improvement of the quality of the electrical data obtained from the application of electrical resistivity tomography method on archaeological studies. The electrical contact between ground and electrode enhances significantly by using carbomer-based gel during the electrical resistivity tomography measurements. Not only does the gel promote the conservation of the building surface under investigation, but it also virtually eliminates the necessity of conventional spike electrodes, which in many archaeological studies are inadequate or not permitted. Results evidenced an enhancement in the quality of the electrical data obtained in the order of thousands of units compared with those without using the carbomer-based gel. The potential and capabilities of this affordable gel make it appropriate to be applied to other geoelectrical studies beyond archaeological investigations. Moreover, it might solve corrosion issues on conventional spike electrodes, and electrical multicore cables usually provoked for added saltwater attempting to improve the electrical contact.
Differences in deposit geometry and texture with depth along ephemeral gravel-bed streams strongly reflect fluctuations in bedload which are due to environmental changes at the basin scale and to morphological channel adjustments. This study combines electrical resistivity tomography (ERT) with datasets from borehole logs to analyse the internal geometry of channel cross-sections in a gravel-bed ephemeral stream (southeast Spain). The survey was performed through longitudinal and transverse profiles in the upper channel stretch, of 14 to 30 m in length and 3 to 6 m in depth, approximately. ERT values were correlated with data on sediment texture as grain size distribution, effective grain sizes, sorting, and particle shape (Zingg’s classification). The alluvial channel-fills showed the superposition of four layers with uneven thickness and arrangement: (1) the softer rocky substrate (5000 Ω.m), corresponding to the most recent armoured deposits (gravel and pebbles). The ERT results coupled with borehole data allowed for determining the horizontal and vertical behaviour of the materials in a 3D model, facilitating the layer identification.
This communication reports an improvement of the quality of the electrical data obtained from the application of electrical resistivity tomography method on archaeological studies. The electrical contact between ground and electrode enhances significantly by using carbomer-based gel during the electrical resistivity tomography measurements. Not only does the gel promote the conservation of the building surface under investigation, but it also virtually eliminates the necessity of conventional spike electrodes, which in many archaeological studies are inadequate or not permitted. Results evidenced an enhancement in the quality of the electrical data obtained in the order of thousands of units compared with those without using the carbomer-based gel. The potential and capabilities of this affordable gel make it appropriate to be applied to other geoelectrical studies beyond archaeological investigations. Moreover, it might solve corrosion issues on conventional spike electrodes, and electrical multicore cables usually provoked for added saltwater attempting to improve the electrical contact.