Soft pneumatic actuators have been explored for endoscopic applications, but challenges in fabricating complex geometry with desirable dimensions and compliance remain. The addition of an endoscopic camera or tool channel is generally not possible without significant change in the diameter of the actuator. Radial expansion and ballooning of actuator walls during bending is undesirable for endoscopic applications. The inclusion of strain limiting methods like, wound fibre, mesh, or multi-material molding have been explored, but the integration of these design approaches with endoscopic requirements drastically increases fabrication complexity, precluding reliable translation into functional endoscopes. For the first time in soft robotics, we present a multi-channel, single material elastomeric actuator with a fully corrugated design (inspired by origami); offering specific functionality for endoscopic applications. The features introduced in this design include i) fabrication of multi-channel monolithic structure of 8.5 mm diameter, ii) incorporation of the benefits of corrugated design in a single material (i.e., limited radial expansion and improved bending efficiency), iii) design scalability (length and diameter), and iv) incorporation of a central hollow channel for the inclusion of an endoscopic camera. Two variants of the actuator are fabricated which have different corrugated or origami length, i.e., 30 mm and 40 mm respectively). Each of the three actuator channels is evaluated under varying volumetric (0.5 mls-1 and 1.5 mls-1 feed rate) and pressurized control to achieve a similar bending profile with the maximum bending angle of 150°. With the intended use for single use upper gastrointestinal endoscopic application, it is desirable to have linear relationships between actuation and angular position in soft pneumatic actuators with high bending response at low pressures; this is where the origami actuator offers contribution. The soft pneumatic actuator has been demonstrated to achieve a maximum bending angle of 200° when integrated with manually driven endoscope. The simple 3-step fabrication technique produces a complex origami pattern in a soft robotic structure, which promotes low pressure bending through the opening of the corrugation while retaining a small diameter and a central lumen, required for successful endoscope integration.
Trans-oral laser microsurgery (TLM) is a surgical procedure for removing malignancies (e.g., cysts, polyps, tumors) of the laryngeal region through laser ablation. Intraoperative microsurgical forceps (i.e., microforceps) are used for tissue manipulation. The microforceps are rigid, single degree-of-freedom (DOF) devices (open–close) with precurved jaws to access different parts of the curved cylindrical laryngeal region. These microforceps are manually handled and are subject to hand tremors, poor reachability, and nonergonomic use, resulting in poor efficacy and efficiency in the surgery. A novel 3DOF motorized microforceps device is presented here, integrated with a 6DOF serial robotic manipulator. The device, referred to as RMF-3, offers three motorized DOFs: (i) open–close forceps jaw; (ii) tool rotation; and (iii) tool-tip articulation. It is designed to be compliant with TLM spatial constraints. The manual handling is replaced by tele-operation device, the omega.7. The design of the RMF-3 is characterized through theoretical and experimental analysis. The device shows a maximum articulation of 38 deg and tool rotation of 100 deg. Its performance is further evaluated through user trials using the ring-in-loop setup. The user trials demonstrate benefits of the 3DOF workspace of the device along with its teleoperation control. RMF-3 offers an improved workspace and reachability within the laryngeal region. Surgeons, in their preliminary evaluation of the device, appreciated the ability to articulate the tip, along with rotation, for hard-to-reach parts of the surgical site. RMF-3 offers an ergonomic robotic teleoperation control interface which overcomes hand tremors and extreme wrist excursion which leads to surgeon pain and discomfort.
21 November 2018 in International Journal of Computer Assisted Radiology and Surgery
In this paper, a novel, motorized, multi-degrees-of-freedom (DoF), microsurgical forceps tool is presented, which is based on a master-slave teleoperation architecture. The slave device is a 7-DoF manipulator with: (i) 6-DoF positioning and orientation, (ii) 1 open/close gripper DoF; and (iii) an integrated force/torque sensor for tissue grip-force measurement. The master device is a 7-DoF haptic interface which teleoperates the slave device, and provides haptic feedback in its gripper interface. The combination of the device and the surgeon interface replaces the manual, hand-held device providing easy-to-use and ergonomic tissue control, simplifying the surgical tasks. This makes the system suitable to real surgical scenarios in the operating room (OR). The performance of the system was analysed through the evaluation of teleoperation control and characterization of gripping force. The new system offers an overall positioning error of less than 400 μm demonstrating its safety and accuracy. Improved system precision, usability, and ergonomics point to the potential suitability of the device for the OR and its ability to advance haptic-feedback-enhanced transoral laser microsurgeries.
23 July 2024 in Biomimetic Intelligence and Robotics
Pulmonary rehabilitation through invasive ventilation involves the insertion of an endotracheal tube into the trachea of a sedated patient to control breathing via a ventilating machine. Invasive ventilation offers benefits such as greater control over oxygen supply, higher efficiency in supporting patient respiration, and the ability to manage airway secretions. However, this method also poses treatment challenges like ventilator-induced pneumonia, airway injury, long recovery times, and ventilator dependence. Here, we explore an alternative invasive ventilation technique using soft robotic actuators to mimic the biological function of the diaphragm for augmenting and assisting ventilation. We have investigated two actuator geometries, each at two locations superior to the diaphragm. These actuators were tested on a bespoke ex-vivo testbed that accurately simulated key diaphragmatic characteristics throughout the respiratory cycle. From this, we have been able to drive intra-thoracic pressures greater than the 5 cmHO required for ventilation in a human male. Additionally, by optimising the placement and geometry of these soft robotic actuators we have been able to generate maximum intra-thoracic pressures of 6.81 ±0.39 cmHO.
Urease is a commonly found enzyme in the natural biological environment like plants, soil, and animals. Its characteristic decomposition is spectroscopically investigated in acidic (chloride) environment for understanding nitrogen cycle.