In this article we demonstrate the performance of a direct conversion amorphous selenium (a-Se) X-ray detector using biphenyldisnhydride/1,4 phenylenediamine (BPDA/PPD) polyimide (PI) as a hole-blocking layer. The use of a PI layer with a-Se allows detector operation at high electric fields (≥10 V/μm) while maintaining low dark current, without deterioration of transient performance. The hole mobility of the PI/a-Se device is measured by the time-of-flight method at different electric fields to investigate the effect of the PI layer on detector performance. It was found that hole mobility as high as 0.75 cm(2)/Vs is achievable by increasing the electric field in the PI/a-Se device structure. Avalanche multiplication is also shown to be achievable when using PI as a blocking layer. Increasing the electric field within a-Se reduces the X-ray ionization energy, increases hole mobility, and improves the dynamic range and sensitivity of the detector.
11 July 2012 in IEEE Transactions on Electron Devices
In this paper, we investigated different organic and inorganic hole-blocking contacts for amorphous selenium (a-Se)-based photodetectors: $\hbox{CeO}_{2}$, $\hbox{TiO}_{2}$, perylene tetracarboxylic bisbenzimidazole (PTCBI), and polyimide (PI). $\hbox{CeO}_{2}$ has previously been used as a blocking layer for high-gain a-Se devices. $\hbox{TiO}_{2}$ has similar properties to $\hbox{CeO}_{2}$. PTCBI has a higher ionization potential compared to a-Se and has a very low hole mobility. PI is a common insulator in the semiconductor industry. It was found that an 800-nm PI layer reduces the dark current by more than two orders of magnitude in comparison with 30 nm of $\hbox{CeO}_{2}$, 20 nm of $\hbox{TiO}_{2}$, and 50 nm of PTCBI. No significant charge trapping was found in the devices consisting of an 800-nm PI layer. Unlike previously reported inorganic hole-blocking contact technology, PI layers further benefit from a simple spin coating fabrication step before evaporation of a-Se. Photodetector samples incorporating the PI layer are tested at high electric fields, and gains reaching 4.4 were observed at an electric field $>\hbox{80}\ \hbox{V}/\mu \hbox{m}$. We conclude that using a PI layer is a promising step in the development of high-conversion-gain detectors for emerging applications in large-area medical diagnostic imaging, crystallography, and nondestructive test.
Anomalous radiation source detection in urban environments is challenging due to the complex nature of background radiation. When a suspicious area is determined, a radiation survey is usually carried out to search for anomalous radiation sources. To locate the source with high accuracy and in a short time, different survey approaches have been studied such as scanning the area with fixed survey paths and data-driven approaches that update the survey path on the fly with newly acquired measurements. In this work, we propose reinforcement learning as a data-driven approach to conduct radiation detection tasks with no human intervention. A simulated radiation environment is constructed, and a convolutional neural network-based double Q-learning algorithm is built and tested for radiation source detection tasks. Simulation results show that the double Q-learning algorithm can reliably navigate the detector and reduce the searching time by at least 44% compared with traditional uniform search methods and gradient search methods.
The kinematics of Compton scatter can be used to estimate the interaction sequence of inter-crystal scatter interactions in 3D position-sensitive cadmium zinc telluride (CZT) detectors. However, in the case of intra-crystal scatter in a ‘cross-strip’ CZT detector slab, multiple anode and cathode strips may be triggered, creating position ambiguity due to uncertainty in possible combinations of anode–cathode pairings. As a consequence, methods such as energy-weighted centroid are not applicable to position the interactions. In practice, since the event position is uncertain, these intra-crystal scatters events are discarded. In this work, we studied using Compton kinematics and a ‘direction difference angle’ to provide a method to correctly identify the anode–cathode pair corresponding to the first interaction position in an intra-crystal scatter event. GATE simulation studies of a NEMA NU4 image quality phantom in a small animal positron emission tomography under development composed of 192, mm CZT crystals shows that 47% of total numbers of multiple-interaction photon events (MIPEs) are intra-crystal scatter with a 100 keV lower energy threshold per interaction. The sensitivity of the system increases from 0.6 to 4.10 (using 10 keV as system lower energy threshold) by including rather than discarding inter- and intra-crystal scatter. The contrast-to-noise ratio (CNR) also increases from to . It was shown that a higher energy threshold limits the capability of the system to detect MIPEs and reduces CNR. Results indicate a sensitivity increase (4.1 to 5.88) when raising the lower energy threshold (10 keV to 100 keV) for the case of only two-interaction events. In order to detect MIPEs accurately, a low noise system capable of a low energy threshold (10 keV) per interaction is desired.
4 January 2013 in IEEE Transactions on Electron Devices
We spectrally demonstrate for the first time that an amorphous selenium metal-semiconductor-metal detector can be used for the measurement of ultraviolet photons (200-400 nm) generated from a portable battery-operated microplasma that is used as a light source. An advantage of this low-cost detector is that the device structure allows photons to strike the light-sensitive layer directly rather than through electrodes or blocking layers. Another advantage is that despite operation at high electric fields of up to 43 V/μm, the dark current of the detector at room temperature is 3 pA/mm2. Therefore, detector cooling is not required, and this facilitates portability for measurements on-site (i.e., in the field and away from a laboratory). Spectral response was monitored using a scanning monochromator, and it was compared with that obtained by a portable spectrometer fitted with a linear charge-coupled device detector. To demonstrate detector responsivity, emission signals with an appreciable signal-to-noise ratio were obtained by introducing nanogram amounts of the sample into the microplasma.