Achim Doerner

Dr. Achim Doerner

Merck Healthcare KGaA, Darmstadt, Germany
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in mAbs
Verified
Journal Article
Open access
RGRamona Gaa
Ramona Gaa
EMEmmanuel Menang-Ndi
Emmanuel Menang-Ndi
SPShruti Pratapa
Shruti Pratapa
CNChristine Nguyen
Christine Nguyen
SKSatyendra Kumar
Satyendra Kumar
ADAchim Doerner
Achim Doerner
Recent years have seen unparalleled development of microfluidic applications for antibody discovery in both academic and pharmaceutical research. Microfluidics can support native chain-paired library generation as well as direct screening of antibody secreting cells obtained by rodent immunization or from the human peripheral blood. While broad diversities of neutralizing antibodies against infectious diseases such as HIV, Ebola, or COVID-19 have been identified from convalescent individuals, microfluidics can expedite therapeutic antibody discovery for cancer or immunological disease indications. In this study, a commercially available microfluidic device, Cyto-Mine, was used for the rapid identification of natively paired antibodies from rodents or human donors screened for specific binding to recombinant antigens, for direct screening with cells expressing the target of interest, and, to our knowledge for the first time, for direct broad functional IgG antibody screening in droplets. The process time from cell preparation to confirmed recombinant antibodies was four weeks. Application of this or similar microfluidic devices and methodologies can accelerate and enhance pharmaceutical antibody hit discovery.

1 January 2020 in mAbs
Verified
Journal Article
Open access
THTim Hofmann
Tim Hofmann
JSJohannes Schmidt
Johannes Schmidt
ECElke Ciesielski
Elke Ciesielski
SBStefan Becker
Stefan Becker
TRThomas Rysiok
Thomas Rysiok
ADAchim Doerner
Achim Doerner
Bispecific antibodies comprise extremely diverse architectures enabling complex modes of action, such as effector cell recruitment or conditional target modulation via dual targeting, not conveyed by monospecific antibodies. In recent years, research on bispecific therapeutics has substantially grown. However, evaluation of binding moiety combinations often leads to undesired prolonged development times. While high throughput screening for small molecules and classical antibodies has evolved into a mature discipline in the pharmaceutical industry, dual-targeting antibody screening methodologies lack the ability to fully evaluate the tremendous number of possible combinations and cover only a limited portion of the combinatorial screening space. Here, we propose a novel combinatorial screening approach for bispecific IgG-like antibodies to extenuate screening limitations in industrial scale, expanding the limiting screening space. Harnessing the ability of a protein trans-splicing reaction by the split intein Npu DnaE, antibody fragments were reconstituted within the hinge region in vitro. This method allows for fully automated, rapid one-pot antibody reconstitution, providing biological activity in several biochemical and functional assays. The technology presented here is suitable for automated functional and combinatorial high throughput screening of bispecific antibodies.

Verified
Journal Article
Open access
PDF file
THTim Hofmann
Tim Hofmann
SKSimon Krah
Simon Krah
CSCarolin Sellmann
Carolin Sellmann
Stefan ZielonkaStefan Zielonka
Stefan Zielonka
ADAchim Doerner
Achim Doerner
Recent years have shown a tremendous increase and diversification in antibody-based therapeutics with advances in production techniques and formats. The plethora of currently investigated bi- to multi-specific antibody architectures can be harnessed to elicit a broad variety of specific modes of actions in oncology and immunology, spanning from enhanced selectivity to effector cell recruitment, all of which cannot be addressed by monospecific antibodies. Despite continuously growing efforts and methodologies, the identification of an optimal bispecific antibody as the best possible combination of two parental monospecific binders, however, remains challenging, due to tedious cloning and production, often resulting in undesired extended development times and increased expenses. Although automated high throughput screening approaches have matured for pharmaceutical small molecule development, it was only recently that protein bioconjugation technologies have been developed for the facile generation of bispecific antibodies in a ‘plug and play’ manner. In this review, we provide an overview of the most relevant methodologies for bispecific screening purposes—the DuoBody concept, paired light chain single cell production approaches, Sortase A and Transglutaminase, the SpyTag/SpyCatcher system, and inteins—and elaborate on the benefits as well as drawbacks of the different technologies.

12 January 2024 in mAbs
Verified
Journal Article
Open access
AEAndreas Evers
Andreas Evers
SKSimon Krah
Simon Krah
DDDeniz Demir
Deniz Demir
RGRamona Gaa
Ramona Gaa
DEDesislava Elter
Desislava Elter
ADAchim Doerner
Achim Doerner
Optimal combinations of paratopes assembled into a biparatopic antibody have the capacity to mediate high-grade target cross-linking on cell membranes, leading to degradation of the target, as well as antibody and payload delivery in the case of an antibody-drug conjugate (ADC). In the work presented here, molecular docking suggested a suitable paratope combination targeting c-MET, but hydrophobic patches in essential binding regions of one moiety necessitated engineering. In addition to rational design of HCDR2 and HCDR3 mutations, site-specific spiking libraries were generated and screened in yeast and mammalian surface display approaches. Comparative analyses revealed similar positions amendable for hydrophobicity reduction, with a broad combinatorial diversity obtained from library outputs. Optimized variants showed high stability, strongly reduced hydrophobicity, retained affinities supporting the desired functionality and enhanced producibility. The resulting biparatopic anti-c-MET ADCs were comparably active on c-MET expressing tumor cell lines as REGN5093 exatecan DAR6 ADC. Structural molecular modeling of paratope combinations for preferential inter-target binding combined with protein engineering for manufacturability yielded deep insights into the capabilities of rational and library approaches. The methodologies of in silico hydrophobicity identification and sequence optimization could serve as a blueprint for rapid development of optimal biparatopic ADCs targeting further tumor-associated antigens in the future.

Verified
Journal Article
Open access
PDF file
NBNadine Barron
Nadine Barron
SDStephan Dickgiesser
Stephan Dickgiesser
MFMarkus Fleischer
Markus Fleischer
ABAngelika-Nicole Bachmann
Angelika-Nicole Bachmann
DKDaniel Klewinghaus
Daniel Klewinghaus
ADAchim Doerner
Achim Doerner
The toolbox of modern antibody engineering allows the design of versatile novel functionalities exceeding nature’s repertoire. Many bispecific antibodies comprise heterodimeric Fc portions recently validated through the approval of several bispecific biotherapeutics. While heterodimerization methodologies have been established for low-throughput large-scale production, few approaches exist to overcome the bottleneck of large combinatorial screening efforts that are essential for the identification of the best possible bispecific antibody. This report presents a novel, robust and miniaturized heterodimerization process based on controlled Fab-arm exchange (cFAE), which is applicable to a variety of heterodimeric formats and compatible with automated high-throughput screens. Proof of applicability was shown for two therapeutic molecule classes and two relevant functional screening read-outs. First, the miniaturized production of biparatopic anti-c-MET antibody–drug conjugates served as a proof of concept for their applicability in cytotoxic screenings on tumor cells with different target expression levels. Second, the automated workflow enabled a large unbiased combinatorial screening of biparatopic antibodies and the identification of hits mediating potent c-MET degradation. The presented workflow utilizes standard equipment and may serve as a facile, efficient and robust method for the discovery of innovative therapeutic agents in many laboratories worldwide.

10 February 2023 in Artificial Cells, Nanomedicine, and Biotechnology
Verified
Journal Article
Open access
RGRamona Gaa
Ramona Gaa
KKKavita Kumari
Kavita Kumari
HMHannah Melina Mayer
Hannah Melina Mayer
DYDesislava Yanakieva
Desislava Yanakieva
STShang-Pu Tsai
Shang-Pu Tsai
ADAchim Doerner
Achim Doerner
Recent years have seen the development of a variety of mammalian library approaches for display and secretion mode. Advantages include library approaches for engineering, preservation of precious immune repertoires and their repeated interrogation, as well as screening in final therapeutic format and host. Mammalian display approaches for antibody optimization exploit these advantages, necessitating the generation of large libraries but in turn enabling early screening for both manufacturability and target specificity. For suitable libraries, high antibody integration rates and resulting monoclonality need to be balanced – we present a solution for sufficient transmutability and acceptable monoclonality by applying an optimized ratio of coding to non-coding lentivirus. The recent advent of microfluidic-assisted hit discovery represents a perfect match to mammalian libraries in secretion mode, as the lower throughput fits well with the facile generation of libraries comprising a few million functional clones. In the presented work, Chinese Hamster Ovary cells were engineered to both express the target of interest and secrete antibodies in relevant formats, and specific clones were strongly enriched by high throughput screening for autocrine cellular binding. The powerful combination of mammalian secretion libraries and microfluidics-assisted hit discovery could reduce attrition rates and increase the probability to identify the best possible therapeutic antibody hits faster.