This paper introduces a novel hybrid filter topology that combines passive and active components to enhance harmonic filtering and resonance damping in electrical power systems. The design integrates a three-phase two-level voltage-source converter with a double-tuned passive filter in parallel, significantly reducing the power rating and operational costs while maintaining good harmonic filtering performance and reactive current compensation. Double-tuned passive filters, compared to single-tuned ones, offer improved harmonic attenuation at multiple frequencies, enhancing overall system efficiency. Moreover, when used with the proposed hybrid filter topology, the double-tuned version allows for even lower dimensions of the active part, thereby further reducing system cost. A state-feedback controller is designed to enhance the performance of the hybrid filter, proving particularly effective in environments with complex impedance conditions. This paper also examines the impact of variations in passive component parameters, demonstrating the design’s robustness against potential deviations expected over the operational lifespan. The results indicate that the hybrid filter effectively mitigates harmonics and maintains operational stability under various transient conditions, as confirmed by analytical and simulation studies on a real industrial network model. These findings underline the hybrid filter’s potential to significantly improve power quality in modern electrical networks.
This paper presents a novel approach for the state estimation of poorly-observable low voltage distribution networks, characterized by intermittent and erroneous measurements. The developed state estimation algorithm is based on the Extended Kalman filter, where we have modified the execution of the filtering process. Namely, we have fixed the Kalman gain and Jacobian matrices to constant matrices; their values change only after a larger disturbance in the network. This allows for a fast and robust estimation of the network state. The performance of the proposed state-estimation algorithm is validated by means of simulations of an actual low-voltage network with actual field measurement data. Two different cases are presented. The results of the developed state estimator are compared to a classical estimator based on the weighted least squares method. The comparison shows that the developed state estimator outperforms the classical one in terms of calculation speed and, in case of spurious measurements errors, also in terms of accuracy.
There has been an increasing trend of integrating photovoltaic power plants (PVs). One of the important challenges for distribution system operators is to evaluate the total installed power of a PV that a particular network can host (or PV hosting capacity) while keeping voltage and element constraints within required limits. The major drawback of the existing methods for calculating PV hosting capacity is that they use the same installed power of the PV systems for all simulated PVs, as these methods do not use external data sources about building roofs. As a consequence, this has a significant impact on the final accuracy of the results. This paper presents a probabilistic methodology for calculating the PV hosting capacity in low voltage (LV) networks. The main contribution of this paper is the improved modeling of PV generation using actual building roof data when calculating the PV hosting capacity, as every building is treated according to its actual solar potential. Monte Carlo simulations with incorporated stochastic consumption and PV generation models are utilized for load flow calculations of the actual LV network. The simulation results presented in this paper prove that the proposed methodology increases the accuracy of the final PV hosting capacity calculations.
This article deals with the influence of distributed generation (DG) on distribution line losses with respect to voltage profile. The article focuses on the development of a control strategy to minimize the grid losses and assure fairness regarding reactive power contributions. As retail customers typically have no choice where they are located along a feeder, it seems unfair that only some of them bear all the burden and responsibility for the voltage rise. On the basis of new technologies, which are capable of fast communication and data processing, a new control system has been proposed that combines classical centralized and local control. The heart of the control system is a load‑flow algorithm, which estimates the voltage drop using a modeled network. Different control solutions were evaluated by means of computer simulations. The simulated network is an actual Slovenian medium-voltage distribution network which covers a large area with diverse feeders and thus gives relatively general results.
4 December 2015 in IEEE Transactions on Power Delivery
Transmission system operators (TSO) should be able to assess power quality levels in a network in order to properly address the mitigation of power quality problems. High flicker levels might be a serious power-quality problem in transmission networks and are usually caused by arc-furnace operation. TSO can assess flicker levels in real time only at nodes where power-quality measurements are available. As for the rest of the system, a TSO could calculate flicker levels, if a reliable and relatively simple method is available. Besides, proper summation of flicker levels originating from several flicker sources remains an issue to tackle. The paper proposes a simple method for the calculation of flicker levels at all nodes of a transmission network based on the known flicker values at multiple flicker-sources and based on the known network topology. Different flicker summation coefficients are compared and the one that gives the smallest error is chosen. The proposed method enables a TSO to continuously assess flicker levels at all network nodes and to investigate the consequences of network changes on flicker levels. The method was verified on the Slovenian transmission network where the results of flicker calculation were compared with available flicker measurements.
Due to a rising share of power electronic devices in power networks and the consequent rise in harmonic distortion, impedance resonances are an important issue. Nowadays, the frequency scan method is used for resonance phenomena identification and analysis. The main disadvantage of the method is its inability to decouple different resonance phenomena. This means that the method is also unable to provide sufficient information about the effects that the parameters of network elements have on different resonance phenomena. Furthermore, it was also noted that despite the fact that the harmonic resonance mode analysis is well described in the literature, there is a lack of systematic approach to the analysis procedure. Thus the main objective of this paper is to address this disadvantage and to propose a systematic approach to harmonic resonance analysis and mitigation, utilizing modal analysis. In the first part of the paper, dominant network nodes in terms of resonance amplification of harmonics are determined. This is done by analysis of the eigenvalues of the network admittance matrix. Using the eigenvalue analysis results, key parameters of network elements involved in a specific resonance are determined next. This is performed by calculating the critical mode (i.e., the mode that experiences resonance) sensitivity coefficients with respect to network parameters. In the second part of the paper, the procedure for modal resonance frequency shift is presented. The shift is performed by changing the value of a selected parameter so that the modal resonance frequency matches the desired resonance frequency value. The parameter value is calculated with the Newton–Rhapson method. Presented analysis considers both parallel and series resonances. The effectiveness of the proposed method is demonstrated on an actual industrial-network model.