Yongshun Liu

Dr. Yongshun Liu

State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2021 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
JMJunyu Ma
Junyu Ma
YWYihui Wu
Yihui Wu
YLYongshun Liu
Yongshun Liu
YJYuan Ji
Yuan Ji
MYMei Yang
Mei Yang
HZHongquan Zhu
Hongquan Zhu
We propose herein a centrifugal microfluidic chip with a flow rectifier that transforms the centrifugal non-steady flow into locally steady flow with continuous flow for size-based cell sorting.

16 September 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
GLGaoge Lian
Gaoge Lian
YLYongshun Liu
Yongshun Liu
KTKeKai Tao
KeKai Tao
HXHuaming Xing
Huaming Xing
RHRuxia Huang
Ruxia Huang
YWYihui Wu
Yihui Wu
Curved compound eyes have generated great interest owing to the wide field of view but the application of devices is hindered for the lack of proper detectors. One-lens curved compound eyes with multi-focal microlenses provide a solution for wide field imaging integrated in a commercial photo-detector. However, it is still a challenge for manufacturing this kind of compound eye. In this paper, a rapid and accurate method is proposed by a combination of photolithography, hot embossing, soft photolithography, and gas-assisted deformation techniques. Microlens arrays with different focal lengths were firstly obtained on a polymer, and then the planar structure was converted to the curved surface. A total of 581 compound eyes with diameters ranging from 152.8 µm to 240.9 µm were successfully obtained on one curved surface within a few hours, and the field of view of the compound eyes exceeded 108°. To verify the characteristics of the fabricated compound eyes, morphology deviation was measured by a probe profile and a scanning electron microscope. The optical performance and imaging capability were also tested and analyzed. As a result, the ommatidia made up of microlenses showed not only high accuracy in morphology, but also imaging uniformity on a focal plane. This flexible massive fabrication of compound eyes indicates great potential for miniaturized imaging systems.

1 September 2016 in International Journal of Speleology
Verified
Journal Article
Open access
PDF file
ZCZhengquan Chen
Zhengquan Chen
YLYongshun Liu
Yongshun Liu
HWHaiquan Wei
Haiquan Wei
JXJiandong Xu
Jiandong Xu
WGWenfeng Guo
Wenfeng Guo
Tube-fed structure occurs as a general phenomenon in Tengchong basic lavas, such as lava tubes, lava plugs and tube-related collapse depressions. We deduced the development of Laoguipo lava flows, which is the longest lava tube (Jingfudong lava tube) evolved in Tengchong volcanic area. Following the detailed documentation of the tube morphology of the Jingfudong lava tube, we propose that the Jingfudong lava tube was formed through vertical coalescence of at least three tubes. The coalescence and bifurcation process are re-constructed by interpretation of tube floor continuity, the distribution of remnant tubes and the scales of lava tube branches (shapes of cross sections). Keywords Tengchong volcanism; Laoguipo volcano; field investigation; lava tube; tube coalescence

1 March 2023 in Acta Biomaterialia
Verified
Journal Article
Closed access
NYNianzuo Yu
Nianzuo Yu
FZFeiran Zhang
Feiran Zhang
XTXiaoduo Tang
Xiaoduo Tang
YLYongshun Liu
Yongshun Liu
JZJunhu Zhang
Junhu Zhang
QWQuan Wang
Quan Wang

21 March 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
KTKekai Tao
Kekai Tao
GLGaoge Lian
Gaoge Lian
YLYongshun Liu
Yongshun Liu
HXHuaming Xing
Huaming Xing
YXYi Xing
Yi Xing
YWYihui Wu
Yihui Wu
Compared with a traditional optical system, the single-lens curved compound eye imaging system has superior optical performance, such as a large field of view (FOV), small size, and high portability. However, defocus and low resolution hinder the further development of single-lens curved compound eye imaging systems. In this study, the design of a nonuniform curved compound eye with multiple focal lengths was used to solve the defocus problem. A two-step gas-assisted process, which was combined with photolithography, soft photolithography, and ultraviolet curing, was proposed for fabricating the ommatidia with a large numerical aperture precisely. Ommatidia with high resolution were fabricated and arranged in five rings. Based on the imaging experimental results, it was demonstrated that the high-resolution and small-volume single-lens curved compound eye imaging system has significant advantages in large-field imaging and rapid recognition.

31 July 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
XFXin Feng
Xin Feng
XLXiao Lv
Xiao Lv
JDJunyu Dong
Junyu Dong
YLYongshun Liu
Yongshun Liu
FSFengfeng Shu
Fengfeng Shu
YWYihui Wu
Yihui Wu
Compound eye cameras are a vital component of bionics. Compound eye lenses are currently used in light field cameras, monitoring imaging, medical endoscopes, and other fields. However, the resolution of the compound eye lens is still low at the moment, which has an impact on the application scene. Photolithography and negative pressure molding were used to create a double-glued multi-focal bionic compound eye camera in this study. The compound eye camera has 83 microlenses, with ommatidium diameters ranging from 400 μm to 660 μm, and a 92.3 degree field-of-view angle. The double-gluing structure significantly improves the optical performance of the compound eye lens, and the spatial resolution of the ommatidium is 57.00 lp mm−1. Additionally, the measurement of speed is investigated. This double-glue compound eye camera has numerous potential applications in the military, machine vision, and other fields.