Sung Gook Cho

Dr. Sung Gook Cho


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2020 in Energies
Verified
Journal Article
Open access
PDF file
SCSung Gook Cho
Sung Gook Cho
Seongkyu ChangSeongkyu Chang
Seongkyu Chang
DSDeokyong Sung
Deokyong Sung
A tuned mass damper (TMD) was developed for mitigating the seismic responses of electrical equipment inside nuclear power plants (NPPs), in particular, the response of an electrical cabinet. A shaking table test was performed, and the frequency and damping ratio were extracted, to confirm the dynamics of the cabinet. Electrical cabinets with and without TMDs were modeled while using SAP2000 software (Version 20, Computers and Structures, NY, USA) that was based on the results. TMDs were designed while using an optimization method and the equations of Den Hartog, Warburton, and Sadek. The numerical models were verified while using the shaking table test results. A sinusoidal sweep wave was applied as input to identify the vibration characteristics of the electrical cabinet over a wide frequency range. Applying various seismic loads that were adjusted to meet the RG 1.60 design response spectrum of 0.3 g then validated the control performance of the TMD. The minimum and maximum response spectrum reduction rates of the designed TMDs were 44.7% and 62.9%, respectively. Further, the amplification factor of the electrical cabinet with the TMD was decreased by 53%, on average, with the proposed optimization method. In conclusion, TMDs can be considered to be an effective way of enhancing the seismic performance of the electrical equipment inside NPPs.

1 October 2020 in CivilEng
Verified
Journal Article
Open access
PDF file
KSKashif Salman
Kashif Salman
SCSung Gook Cho
Sung Gook Cho
To ensure the stable operation of safety-related nuclear power plant (NPP) equipment, they are tested by following the seismic qualification procedures. The in-cabinet response spectrum (ICRS) is used to test the mounted components. However, the ICRS varies significantly with the number of uncertainties that include (1) loaded and unloaded condition of the cabinets, (2) the number of connected cabinets (grouping effects), and (3) higher frequency contents in the seismic inputs. This study focuses on the ICRS generation and alteration induced due to the listed uncertainties. A prototype of an electrical cabinet was experimentally examined. Followed by the numerical modeling of the cabinet, the seismic analysis for the group of cabinets was performed using artificial ground motion compatible with the standard design spectrum and the real accelerograms of high and low frequency contents. The seismic response using finite element (FE) analysis manifests (1) natural frequency of loaded cabinets reduced due to the in-cabinet components while for the unloaded cabinets it increased significantly, (2) a consistent reduction in ICRS due to the grouping effect was recorded when excited by the lower-frequency motion, while it was amplified dramatically due to high-frequency pulses. Interconnected cabinets under the low-frequency input motions have a significant reduction of 50% in the ICRS that corresponds to the higher stiffness of the cabinets, while a 100% increase under the high frequency of ground motion was obtained. High frequency of ground motion, usually above 10 Hz, can cause the interconnected cabinets to resonate as the natural frequency of these equipment lies in this range.

30 June 2020 in Journal of the Earthquake Engineering Society of Korea
Verified
Journal Article
Closed access
RCR&D Center Ceo
R&D Center Ceo
SCSung Gook Cho
Sung Gook Cho
AGAbhinav Gupta
Abhinav Gupta

9 July 2021 in Journal of Pressure Vessel Technology
Verified
Journal Article
Closed access
PDF file
AGAbhinav Gupta
Abhinav Gupta
ADAnkit R. Dubey
Ankit R. Dubey
SCSung Gook Cho
Sung Gook Cho
Nuclear industry spends enormous time and resources on designing and managing piping nozzles in a plant. Nozzle locations are considered as a potential location for possible failure that can lead to loss of coolant accident. Industry spends enormous time in condition monitoring and margin management at nozzle locations. Margins against seismic loads play a significant role in the overall margin management. Available margins against thermal loads are highly dependent upon seismic margins. In recent years, significant international collaboration has been undertaken through Nuclear Energy Agency (NEA) to study the seismic margin in piping systems and nozzles through experimental and analytical studies. It has been observed that piping nozzles are highly overdesigned and the margins against seismic loads are quite high. While this brings a perspective of sufficient safety, such excessively high margins compete with available margins against thermal loads particularly during the life extension and subsequent license renewal (SLR) studies being conducted by many plants around the world. This paper focuses on identifying and illustrating two key reasons that lead to excessively conservative estimates of nozzle fragilities. First, it compares fragilities based on conventional seismic analysis that ignores piping–equipment–structure interaction on nozzle fragility with the corresponding assessment by considering such interactions. Then, it presents a case that the uncertainties considered in various parameters for calculating nozzle fragility are excessively high. The paper identifies a need to study the various uncertainties in order to achieve a more realistic quantification based on recent developments in our understanding of the seismic behavior of piping systems.

4 June 2020 in Journal of Pressure Vessel Technology
Verified
Journal Article
Closed access
PDF file
ADAnkit R. Dubey
Ankit R. Dubey
AGAbhinav Gupta
Abhinav Gupta
SCSung Gook Cho
Sung Gook Cho
Fragility assessment requires characterization of a component or system's performance through a performance function/limit-state equation. The exceedance of limit-state is representative of failure or damage state. For the purposes of evaluating piping fragility, characterizing the behavior of T-joints through an appropriate performance function is critical, as failures in piping are generally localized at the location of T-joints, elbows, and nozzles. Past studies have utilized a monotonic rotation-based performance function. However, the existing criteria does not account for the effect of cyclic behavior. As observed during prior experimental studies, the T-joint behavior under cyclic loading is different from that under monotonic loading, and therefore, it is important to include the effects of cyclic behavior while characterizing a performance function. Moreover, the monotonic rotation-based performance function could not replicate all the leakage locations observed during experimental studies on a full-scale two-story piping system. Therefore, it is important to develop a new limit-state for accurate piping fragility assessment. This paper presents the development of a new limit state which considers the cyclic behavior of a T-joint and quantifies the number of cycles to failure.

10 July 2021 in International Journal of Steel Structures
Verified
Journal Article
Closed access
PDF file
ADAnkit R. Dubey
Ankit R. Dubey
AGAbhinav Gupta
Abhinav Gupta
SCSung Gook Cho
Sung Gook Cho