Lithium-ion batteries (LiBs) are a proven technology for energy storage systems, mobile electronics, power tools, aerospace, automotive and maritime applications. LiBs have attracted interest from academia and industry due to their high power and energy densities compared to other battery technologies. Despite the extensive usage of LiBs, there is a substantial fire risk associated with their use which is a concern, especially when utilised in electric vehicles, aeroplanes, and submarines. This review presents LiB hazards, techniques for mitigating risks, the suppression of LiB fires and identification of shortcomings for future improvement. Water is identified as an efficient cooling and suppressing agent and water mist is considered the most promising technique to extinguish LiB fires. In the initial stages, the present review covers some relevant information regarding the material constitution and configuration of the cell assemblies, and phenomenological evolution of the thermal runaway reactions, which in turn can potentially lead to flaming combustion of cells and battery assemblies. This is followed by short descriptions of various active fire control agents to suppress fires involving LiBs in general, and water as a superior extinguishing medium in particular. In the latter parts of the review, the phenomena associated with water mist suppression of LiB fires are comprehensively reviewed.
Lithium-ion batteries (LIBs) are used extensively worldwide in a varied range of applications. However, LIBs present a considerable fire risk due to their flammable and frequently unstable components. This paper reviews experimental and numerical studies to understand parametric factors that have the greatest influence on the fire risks associated with LIBs. The LIB chemistry and the state of charge (SOC) are shown to have the greatest influence on the likelihood of a LIB transitioning into thermal runaway (TR) and releasing heats which can be cascaded to cause TR in adjacent cells. The magnitude of the heat release rate (HRR) is quantified to be used as a numerical model input parameter (source term). LIB chemistry, the SOC, and incident heat flux are proven to influence the magnitude of the HRR in all studies reviewed. Therefore, it may be conjectured that the most critical variables in addressing the overall fire safety and mitigating the probability of TR of LIBs are the chemistry and the SOC. The review of numerical modeling shows that it is quite challenging to reproduce experimental results with numerical simulations. Appropriate boundary conditions and fire properties as input parameters are required to model the onset of TR and heat transfer from thereon.