Achieving urban sustainability is a complex process that includes improving buildings’ resilience and energy efficiency by using the optimum thermal insulation solution. With the advent of new energy restrictions, it is very important to find the best compromise between the price of the thermal insulation material and energy savings because, sometimes, the initial cost of a thermal rehabilitation seems to be very high. The purpose of this study is to illustrate the variations in the amount of heat energy required by a multi-storey residential structure in Romania that uses 14 various kinds of thermal insulation materials. The energy demand is determined using the dynamic method using a building energy simulator that can evaluate the energy usage of lighting, warmth, ventilation, climate control, and water heating.
The paper aims to assess the energy performance of a thermal rehabilitated ground floor building by using new thermal insulation panels with double-side anti-condensation foil on the exterior and polyurethane foam or polyisocyanurate on the interior (PUR or PIR) in various ways. The study also wants to emphasize the benefits of using these insulating materials encouraging their further use. Therefore, five scenarios are carried out, four thermal rehabilitation scenarios and the reference building scenario, without thermal insulation. The obtained results are evaluated by comparison. The results point out the energy performance of PUR and PIR used as thermal insulation panels for the building envelope but also the economic impact and the economic efficiency that involves using such panels. This work is based on the energy efficiency requirements targeting the building envelope and takes into account mainly the behavior of the envelope elements while the heating system is treated in a simplified manner, considering its usual efficiency. The conclusions highlight the main advantages of using these panels for buildings thermal rehabilitation compared to other common materials, such as polystyrene or mineral wool.
The purpose of this study is to determine the differences between the steady-state energetic method and the dynamic energetic method in a multi-storey residential building in Romania. For both methods, there are two values for the heating energy demand, one obtained with the theoretical U value and g value according to Romanian Methodology Mc 001/1-2006 and one with the real U value and g value obtained from in situ measurements. The results of our study revealed a difference between the steady-state method and the dynamic method in both cases of approximately 20%. Because the heating energy demand needs to decrease in value according to European legislation and the classical energy demand determination is shallow, as it does not take into account some important factors, it is important to use a method that produces accurate values so the economic factor does not become overwhelming.
The aim of the paper is to identify energy inefficiencies and to propose energy-saving solutions to reduce the carbon footprint of the structures, considering Building Information Modelling—Existing Conditions Model as an enabling tool. The initiative underscores the role of Building Information Modelling—Existing Conditions Model in facilitating data-driven strategies for improving energy efficiency, highlighting its potential to transform the infrastructure and built environment into a paradigm of responsible energy consumption. In this context, the paper presents a comprehensive assessment of the thermal performance of student accommodations using advanced technologies, such as Unmanned Aerial Systems and Terrestrial Laser Scanners equipped with thermal cameras. The findings illustrate potential areas for improvements in thermal efficiency, offering a roadmap for targeted interventions to enhance the energy performance of buildings. The results of the study not only advance the green campus at Politehnica University Timisoara (Romania), but also serve as an educational model that demonstrates the integration of technology to promote sustainability in the built environment.
The concept of sustainability has become a priority in the construction field, in a context where there is an increasing discussion about reducing carbon dioxide emissions, as the construction industry is one of the most polluting industries with a focus on the production of building materials. At present, the classic solution used for structural masonry walls worldwide is the ceramic block. Given that the production of ceramic blocks represents an environmentally polluting process, the alternative solution of using concrete blocks with wood chips is proposed. The proposed solution is more environmentally friendly, both in terms of production technology and materials used, as it is made of wood chips, wood being a sustainable material. These types of blocks are currently used in non-seismic areas due to their poor structural performance. This paper deals with a study on the use of recyclable materials, such as wood chips, from waste materials and aims to propose viable solutions for the use of this type of blocks for structural walls in seismic areas. Two solutions, including concrete blocks with wood chips, have been proposed and numerical analyses have been carried out. Numerical analyses were also carried out for the classical solutions, so that, finally, a comparison could be made between them from a structural point of view. Following the numerical analysis of four types of walls, the two proposed solutions of concrete blocks with wood chips had the best results in terms of force–displacement relationship. Moreover, the quantitative results are presented in a force–displacement graph for the four wall types. This stage represents the first phase of the research, while phase II will continue with experimental tests of the proposed solutions.
1 May 2016 in Journal of Applied Engineering Sciences
This paper presents a study on using the steady-state three-dimensional heat transfer software HEAT3 for evaluating the heat flow of heat transfer through different elements of the building envelope in order to establish the linear thermal transmittance of the linear thermal bridge. The linear thermal transmittance is obtained according to the one-dimensional steady-state heat transfer calculation formula for the plane walls using the heat flow values obtained through the method specified above. The results presented in this paper are part of a wider study on evaluating the heat transfer through building’s envelope elements by evaluating as accurate as possible the thermal bridges effect of the most common building structures. As a case study, it was considered the steady-state heat transfer through an opaque outer wall of a building considering the thermal bridges for the following elements: outer walls intersection, inner and outer wall intersection and outer wall with intermediate floor intersection.