Peter Andris

Dr. Peter Andris

Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovak Republic
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2015 in Measurement
Verified
Journal Article
Closed access
PAPeter Andris
Peter Andris
TDTomáš Dermek
Tomáš Dermek
IFIvan Frollo
Ivan Frollo

23 February 2011 in Measurement Science and Technology
Verified
Journal Article
Closed access
PAPeter Andris
Peter Andris
IFI Frollo
I Frollo

30 June 2009 in Measurement
Verified
Journal Article
Closed access
PAPeter Andris
Peter Andris
IFIvan Frollo
Ivan Frollo

1 January 2010 in Measurement Science Review
Verified
Journal Article
Open access
PDF file
IFI. Frollo
I. Frollo
PAPeter Andris
Peter Andris
JPJ. Přibil
J. Přibil
LVL. Vojtíšek
L. Vojtíšek
TDT. Dermek
T. Dermek
LVL. Valkovič
L. Valkovič
Measurement and Imaging of Planar Electromagnetic Phantoms Based on NMR Imaging MethodsPlanar electromagnetic phantom design for measurement and imaging using NMR has been performed. Electromagnetic phantom computation and testing on a NMR 0.178 Tesla Esaote Opera imager were accomplished. The classical geometrical and chemical phantoms are generally used for testing of NMR imaging systems. They are simple cylindrical or rectangular objects with different dimensions and shapes with holes filled with specially prepared water solutions. In our experiments a homogeneous phantom (reference medium) - a container filled with water - was used. The resultant image represents the magnetic field distribution in the homogeneous phantom. An image acquired by this method is actually a projection of the sample properties onto the homogeneous phantom. The goal of the paper is to map and image the magnetic field deformation using NMR imaging methods. We are using a double slender rectangular vessel with constant thickness filled with specially prepared water solution in our experiments. For detection a carefully tailored gradient-echo imaging method, susceptible to magnetic field homogeneity, was used.

1 September 2014 in Measurement
Verified
Journal Article
Closed access
PAPeter Andris
Peter Andris
VJVlado Jacko
Vlado Jacko
TDTomáš Dermek
Tomáš Dermek
IFIvan Frollo
Ivan Frollo

1 December 2015 in Measurement Science Review
Verified
Journal Article
Open access
IFIvan Frollo
Ivan Frollo
AKAndrej Krafčík
Andrej Krafčík
PAPeter Andris
Peter Andris
Jiri PribilJiri Pribil
Jiri Pribil
TDTomáš Dermek
Tomáš Dermek
Circular samples are the frequent objects of "in-vitro" investigation using imaging method based on magnetic resonance principles. The goal of our investigation is imaging of thin planar layers without using the slide selection procedure, thus only 2D imaging or imaging of selected layers of samples in circular vessels, eppendorf tubes,.. compulsorily using procedure "slide selection". In spite of that the standard imaging methods was used, some specificity arise when mathematical modeling of these procedure is introduced. In the paper several mathematical models were presented that were compared with real experimental results. Circular magnetic samples were placed into the homogenous magnetic field of a low field imager based on nuclear magnetic resonance. For experimental verification an MRI 0.178 Tesla ESAOTE Opera imager was used.